Fema Electronica Series MAG-35, MAG-35-36 User Manual

FEMA ELECTRÓNICA - Page 1
Panel meters for PROCESS signals in Vdc
FEMA ELECTRÓNICA
STANDARD
PANEL
METERS
USER’S MANUAL
Series MAG-35
IDEAL SOLUTION to display process signals in 0/10 Vdc and similar up to 200Vdc, with display scaled in engineering units. Provides excitation voltage output to power-up transducers. Available options for relay output, analogue output, serial outputs and others. Multiple input signal ranges selectable by internal jumpers.
MAG-35-36 for process 0/10 Vdc and similar
FEMA ELECTRÓNICA - Page 2
User’s Manual - MAG-35 Process (Model 36)
Instrument for PROCESS in Vdc
Panel meter to measure process signals in 0/10 Vdc and similar, up to 200 Vdc. Display scalable in engineering units. Input ranges selectable by internal jumpers and scaling of the display by potentiometers. Provides excitation voltage from 10 to 24 Vdc regulated, to power-up transducers. Accepts signals from transducers using 2, 3 and 4 wire connection techniques.
Additional options with relay outputs (1 or 2 relay), analogue outputs (in mA and Vdc), digital outputs in serial code (RS232 or RS485), parallel BCD code, display «Hold» function and power options in AC and DC.
Model MAG-35-36
OUTPUT AND CONTROL OPTIONS
MAG-35 instruments can be supplied with different options for data output and control. Compatibility between them is indicated at the «Ordering Reference» section down on this page. Technical data and operating instructions for these options are indicated in a separate user’s manual.
«SP11» 1 Relay Output «SP21» 2 Relay Output «SAR» Analogue Output «HM» Hold of display «MPA2» Detection of «peak and drop» signals «SDA» Parallel BCD «RS2» Serial RS232 output «RS4» Serial RS485 output
POWER OPTIONS
MAG-35 instruments can be supplied with different power options, for different AC and DC power ranges. The instruments do not have internal protection fuse. The value and type of the recommended fuse for each power type is indicated below.
Ref. Power Recommended Fuse
«0» 230 Vac 50/60 Hz 50 mA Time Lag «1» 115 Vac 50/60 Hz 100 mA Time Lag «2» 24 Vac 50/60 Hz 300 mA Time Lag «3» 48 Vac 50/60 Hz 150 mA Time Lag «6» 24 Vdc (15/30 Vdc Isolated) 350 mA Fast Fuse «8» 48 Vdc (24/65 Vdc Isolated) 200 mA Fast Fuse
DISPLAYS Led 7 Segments Red Color DIGIT HEIGHT 14 mm (0.55’’) DISPLAY ±1.8.8.8 POLARITY Automatic ± DECIMAL POINTS Jumper selectable
INPUT CONFIGURATION Bipolar Simple A/D CONVERTER Dual slope INTEGRATION TIME 80 mSec. NUMBER OF READINGS 3.12 per second WARM-UP TIME 2 minutes
ACCURACY 0.15% ±1 digit NMRR 50 dB THERMAL DRIFT 100 ppM TEMPCO ZERO 0.13% /ºC F.S.
OVERRANGE +1999 flash UNDERRANGE -1999 flash
WORKING TEMP. 0°C to +50°C STORAGE TEMP. -40°C to +80°C BURN-IN 48 hours RECALIBRATION Yearly
HOUSING DIN 43700 DIMENSIONS 96 x 48 x 117 mm PANEL CUT-OUT 44.5 x 92.5 mm WEIGHT 310 gr. CONNECTIONS Plug-in screw clamps
CONSUMPTION 5.5 VA in AC
3.5 W in DC
GENERAL SPECIFICATIONS
Model Power Option1 Option2 Option3 Scaling
MAG-35 - - - - - -
36 0 SP11 SAR HM 0/10 Vdc = 0/150.0 mm
1 SP21 MPA2 -20/+150 Vdc = 0/580 BAR 2 SDA ... 3 RS2 6 RS4 8
ORDERING REFERENCE
Loading...