Felton Digital SMARTVIEW FD-SVCSMC User Manual

USER GUIDE
SMARTVIEW™
Digital Thermostatic Shower Mixer
FD-SVCSMC
1
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully before using this system and keep in a safe place for future reference.
To reduce the risk of electric shock and injury, basic safety precautions, including the following, should always be followed when
using electrical appliances. Children MUST be supervised at all times when using this shower control. Training should be given
to children and vulnerable individuals before permitting them to operate the control. Do not pull on the power cable: this may damage it and cause electric shock. Never operate any appliance with damaged cable or plug. Do not use an appliance that has been dropped or damaged or after any malfunctions.
WARNING
Continuously turning the control wheel in the clockwise direction may override the preset maximum
temperature, with consequent risk of scalding. Always take care when operating the control wheel, and do not leave children unattended whilst the product is in operation.
PRECAUTIONS
1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with the appliance.
3. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
4. This appliance contains battery that are only replaceable by skilled persons.
5. An electronic copy of installation and user guides are available on Felton Digital website – please visit www.feltondigital.co.nz
to view le.
FELTON DIGITAL SMARTVIEW™
The premium level digital shower mixer with easy to understand icons, Felton’s Smartview™ is a Swiss technology which
features the TLI Vision Wheel and menu navigation display. Alongside the thermostatic function and built in temperature colour
visualisation, the Smartview creates a safer shower environment for everyone in the household by preventing hot scalds and
cold shocks when someone else in the house is using water at the same time.
Regular shower mixers rely on manual control to regulate ow and temperature. When the hot or cold water supply to a manual
shower mixer uctuates, so does the temperature of the shower. This may cause a sudden, unpleasant cold shock or potentially
dangerous hot scald as the user scrambles to adjust the mixer back to a comfortable shower temperature.
There are three programmable memory settings to customise your very own shower experience and additional features
including maximum temperature, diagnostics, and hygiene functions are programmable via the protected input area.
The Smartview™ thermostatic shower mixer saves water and energy because it heats up to your shower temperature more
quickly and eciently.
The monochrome OLED displays the actual water usage, along with the current temperature reading - a real incentive to save
precious water resources.
Additional functions can be set on installation including maximum run time and temperature, diagnostics and clean mode.
A safety stop slows temperature increase after 40 degrees.
Diverter
User lock
Eco stop
Thermal disinfection
Diagnostic
Factory setting
Temperature
Water indicator
Selection between two water outlets
Disabling the unit for 45 sec
The control unit can be switched o after 30 minutes on default
Slower temperature increase after 40°C
Flushing the outlet with hot water for 5 min
Checking the vision wheel with error indicator
Resetting to factory settings
Choose between Celsius (°C) and Farenheit (°F)
Shows the actual water consumption
FELTON INDUSTRIES LTD
8 Farmhouse Lane, Glen Innes, Auckland 1072
CONTENTS
Operating the water control system
Display icons 5
Operating the control system 6
Operating the ow control 7
Diverting the water ow 7
Switching between temperature/ow 7
Setting up temperature/ow memory 8
Menu functions 9
Accessing the extended menu display 12
Extended menu features 13
Troubleshooting 17
Warranty 18
4
DISPLAY ICONS
Shower Processor
Flow and temperature
Save/delete current pre-sets. Quick access to extended menu.
Backwards/return
Cleaning mode: disables the control
for 45 seconds
Shows the total amount and last usage of water consumption
Access and lock to extended
menu/features with a 3 digit code
Setting maximum run-time (until automatic switch-o)
Setting the maximum outlet temperature
Self check diagnosis: Inspection of control unit and water supply
Statistics
Change from Celsius to Fahrenheit
Thermal disinfection (emergency stop by pressing control) Water will ow at
maximum temperature for 5 minutes
Reset to factory settings
Set a new code
LIVE DISPLAY (activated water supply)
Quick
Access
Icon symbol
Total water
value (optional)
To select/enter = Menu button/wheel
When menu is idle for more than 10 seconds,
unit becomes inactive.
Temperature
Actual water
consumption
MENU BUTTON
CONTROL WHEEL
MAIN MENU BASIC FUNCTIONS
To scroll through icons = Rotate the wheel left or right
When the required icon is highlighted, press menu/wheel button to select.
To enter: Turn on unit then press the menu button
MAIN MENU EXTRA FUNCTIONS
To enter: Press the menu button
5
OPERATING THE CONTROL SYSTEM
To turn ON To turn OFF
Press the wheel once, the control will illuminate Orange and
water will start to ow.
Press the wheel once, the water and light will
turn o.
SETTING TEMPERATURE
Important: Risk of scalding, please read the Safety Information before using.
COLD WARM HOT
Turn the wheel anti­clockwise, the control will illuminate
blue and will ash until
the set temperature is reached.
Note: When turned on, the default temperature setting is 36°C. After 40°C, increasing temperature slows down to avoid risk of scalding.
Turn the wheel clockwise, the control will illuminate Orange,
the light will ash until
the temperature is reached.
6
Continue turning the
wheel clockwise, the control will illuminate
Red, the light will ash
until the set temperature is reached.
Loading...
+ 14 hidden pages