Kata™ slider mount components and tools
VESA mount assembly (1)
caution
• Hand tighten screws only. Do not use power tools.
Please review these instructions before beginning the installation. Use the illustrations below to check that all the components needed for your installation were provided with your order. Do not discard the packaging until the product works to your satisfaction.
components and tools
slider bar (1)
VESA plate screws (4)
M4x10
additional tools required
• Phillips screwdriver
dual Allen key (1)
2mm and 4mm
VESA locking screw (1)
M4x15
slider mount set screw (1)
M4x9
Kata™ slider mount retrot procedure
screw cover
socket cap
screw
4mm Allen key
step 1: remove monitor from VESA mount
• Disconnect the monitor cables.
push tab forward
• If a VESA locking screw is installed, remove it using the 2mm Allen key, as shown below.
• Push forward the tab at the top of the VESA
VESA plate
plate and lift the monitor upward.
• Place the monitor face down on a flat surface.
remove
VESA locking screw
M4x15
VESA
mount
2mm Allen key
step 2: remove VESA mount from monitor arm
• Remove the socket cap screw cover from the underside of the monitor arm.
• Remove the socket cap screw using the 4mm Allen key.
• Pull the VESA mount from the monitor arm.
— There are two bushings on which the VESA mount swivels, as shown in the right illustration. Remove
the bushings and save them for re-use. [Or: You may re-use the bushings or use the new ones provided.]
4mm Allen key
socket cap
screw cover
upper bushing
lower bushing
screw
Page 3
Kata™ slider mount retrot procedure
step 3: assemble slider mount
IMPORTANT: When assembling the slider mount, the groove on the slider bar must be at the bottom.
• Slide the VESA mount assembly onto the slider bar. Center the assembly on the slider bar.
• Install the M4x15 locking screw into the bottom of the VESA mount assembly. Using the 2mm Allen key, tighten the locking screw to hold the assembly in place. Be sure the screw fits into the groove.
— After the monitor has been installed, the VESA mount can be moved anywhere along the slider bar
by loosening the locking screw no more than one full turn, so that it stays inside the groove. Be sure to re-tighten the screw to secure the monitor in the desired position.
groove
slider mount set screw
VESA mount
assembly
slider bar
M4x9
2mm
Allen key
step 4: position slider mount on monitor arm
• First, position the bushings.
— Place the upper bushing on the top opening of the slider mount. — Place the lower bushing onto the bottom opening of the monitor arm.
• Position the slider mount onto the monitor arm. Be sure the bushings remain in place.
lower bushing
Page 4
upper
bushing
Kata™ slider mount retrot procedure
lower bushing
upper
bushing
step 5: attach slider mount
• Secure the slider mount using the socket screw.
— Do not over-tighten. The slider mount should hold its position, but still
swivel when force is applied.
• Install the socket screw cover.
socket cap
screw
screw cover
step 6: remove VESA plate from VESA mount
• Remove the VESA plate from the VESA mount by pushing forward the tab at the top and lifting upward.
4mm
Allen key
push tab forward
VESA plate
VESA
mount
slider
Page 5
Kata™ slider mount retrot procedure
(75mm)
step 7: only if not reattaching original monitor: attach VESA plate to new monitor
Skip this step if you are using the original monitor.
• Place the monitor face down on a flat surface. Align the VESA plate holes with the holes on the back of the monitor. Attach the VESA plate using the four VESA plate screws provided.
— There are two sets of four holes on the VESA plate. One set has holes 3.9” (100mm) apart, the other
set has holes 3” (75mm) apart. Use the set that matches the holes on the rear of the monitor.
top
VESA plate
VESA plate screw
step 8: attach monitor to VESA mount
• Slide the VESA plate and monitor onto the VESA mount.
— Make sure the VESA plate clicks securely
in place.
• OPTIONAL: Secure the VESA plate to the VESA mount using the M4x15 VESA locking screw, as shown below.
3.9"
(100mm)
monitor
(face down)
3"
VESA plate
2mm Allen key
VESA locking screw
M4x15
Page 6
VESA
mount
Kata™ slider mount retrot procedure
slide
down to
install
step 9: organize cables and cords
• Connect the monitor cables and cords.
• Capture the cables and cords with the cable covers. Slide the cable covers downward to attach them to the monitor arms.
• Route the monitor cables and power cords toward the rear by slipping the cords into the opening on the cable clips.
install
over
cables
capture
cables in clip
step 10: adjust monitor position, if desired
• Loosen the slider mount set screw with the 2mm Allen key. Slide the monitor to the desired position on the slider bar and then re-tighten the set screw.
• All tension adjustments are the same as before the slider mount retrofit:
1. Monitor swivel adjustment (4mm Allen key)
2. Motion arm weight adjustment (4mm Allen key)
3. Monitor tilt adjustment (4mm Allen key)
4. Motion arm swivel adjustment (4mm Allen key)
5. Fixed arm swivel adjustment (2mm Allen key)
2mm Allen
key
2
behind
slider
3
monitors
not shown
1
4
Page 7
5
Kata slider mount
VESA slider retrot
Please contact Customer Service with any questions or comments at 800.833.3746 or visit our website at esiergo.com
LIMITED WARRANTY
ESI warrants this product to be free from defects in manufacturing for a period of 15 years from the date of original purchase. This warranty extends only to the original purchaser, and does not apply if the produc t has been damaged or fails to function properly as a result of misuse, abuse, modification, alteration, or improper cleaning or maintenance. This warranty does not apply to damage in shipment caused by carriers, damage caused during installation, normal wear and tear, or excessive use (meaning consistent use in excess of an eight hour shift). ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL RETAIL PURCHASE. ESI’s sole obligation under this warranty or any implied warranty, and the purchaser’s sole remedy, is limited to the repair or replacement, at ESI’s option, of the product or any defective par t. Costs (such as installation, labor fees or express shipping) incurred due to replacement of product s are not covered under warranty. IN NO EVENT SHALL FELLOWES, ITS AFFILIATES, SUBSIDIARIES, RELATED ENTITIES OR THEIR RESPECTIVE OFFICERS, DIRECTORS, OR EMPLOYEES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY, OR SPECIAL DAMAGES.
To make a warranty claim, contact ESI at 800-833-3746 or customerservice@esiergo.com. You must provide proof of purchase, such as the original purchase order number.