Fellowes B2385654 User Manual

CUSTOMER SERVICE & SUPPORT
www.fellowes.com
U.S.: 1-800-955-0959 Canada: 1-800-665-4339 Mexico: 001-800-514-9057
AeraMax-190
Air Purier | Puricateur d’air | Puricador de aire
Please read these instruc­tions before use. Do not discard: keep for
1789 Norwood Avenue, Itasca, Illinois 60143 • 1-800-955-0959 • www.fellowes.com
Brands
© 2017 Fellowes, Inc. | Form #870327 Rev B
AeraMax-190_870327_RevB_3L_032117.indd 1-2 4/21/17 9:55 AM
future reference.
Veuillez lire ces instruc­tions attentivement avant d’utiliser le produit. Conservez ce manuel à titre de référence.
Lea estas instrucciones antes del uso. No las descarte: consérvelas como referencia futura.
TABLE OF CONTENTS
SAFETY INSTRUCTIONS
Warranty .................................................... 2
Package Contents .................................... 2
Safety Instructions .....................................3
Product Specications ...............................4
Display Panel ............................................ 7
Operation ...................................................8
Care and Maintenance .........................9-10
Troubleshooting .......................................11
Air Purier Features.................................. 5
Air Purier Set-Up..................................... 6
LIMITED PRODUCT WARRANTY
Limited Warranty: Fellowes, Inc. (“Fellowes”) warrants the parts of the machine to be free of defects in material and workmanship and provides service and support for 3 years from the date of purchase by the original consumer. If any part is found to be defective during the warranty period, your sole and exclusive remedy will be repair or replacement, at Fellowes’ option and expense, of the defective part. This warranty does not cover damage caused by use of non-Fellowes approved lters or failure to fol­low the recommended replacement schedule. This warranty does not apply in cases of abuse, mishan­dling, failure to comply with product usage standards, operation using an improper power supply (other than listed on the label), or unauthorized repair. Fellowes reserves the right to charge the consumers for any additional costs incurred by Fellowes to provide parts or services outside of the country where the air purier is initially sold by an authorized reseller. This warranty does not include the air cleaner’s replaceable lters, this is an expendable part that can wear out from normal use before three years expire. ANY IMPLIED WARRANTY, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED IN DURATION TO THE APPROPRIATE WARRANTY PERIOD SET FORTH ABOVE. In no event shall Fellowes be liable for any consequential or incidental damages attributable to this product. This warranty gives you specic legal rights. The duration, terms, and conditions of this warranty are valid worldwide, except where different limitations, restrictions, or conditions may be required by local law. For more details or to obtain service under this warranty, please contact us or your dealer.
PACKAGE CONTENTS
• Fellowes® AeraMax™ Air Purier
• True HEPA Filter with AeraSafe™
Antimicrobial Treatment (1 lter)
• Carbon Filter (1 lter)
• Instruction Sheet
• Survey Card
Thank you for purchasing a Fellowes® Air Purier. Please read this manual carefully before using. This product is for indoor use
only.
IMPORTANT CAUTIONS AND INSTRUCTIONS FOR USING YOUR AIR PURIFIER
WARNING: Follow the instructions in this
manual to reduce the risk of electric shock,
short circuit, and/or re:
• Do not repair or modify the unit unless
specically recommended in this manual. All repairs should be completed by a qualied technician.
• The plug for this unit is polarized with
one blade wider than the other. Do not force the plug into an electrical outlet.
• Do not alter the plug in any way. If the
plug does not t into the outlet, reverse the plug. If it still does not t, contact a qualied technician to install a proper outlet.
• Do not use if the power cord or plug is
damaged or the connection to the wall outlet is loose.
• Use AC 120V only.
• Do not damage, break, forcefully bend,
pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
• Periodically remove dust from the
power plug. This will reduce the chance
that humidity will accumulate, which increases the risk of electric shock.
• If the power plug is damaged, it must
be replaced by the manufacturer or a qualied technician.
• Remove the power plug from the outlet
before cleaning the unit. When removing
the power plug, grasp by holding the plug
itself, never hold by the cord.
• Remove the power plug from the outlet
when the unit is not in use.
• Do not handle the power plug with wet hands.
• Do not operate the unit when using
indoor smoke-generating insecticides.
• Do not clean unit with benzene or paint thinner. Do not spray insecticides on
the unit.
• Do not use the unit where it is humid or where the unit may get wet, such as in a bathroom.
• Do not insert ngers or foreign objects
into the air intake or outlet.
• Do not use the unit near ammable gases. Do not use near cigarettes, incense, or other spark-creating items.
• Unit will not remove carbon monoxide emitted from heating appliances or
other sources.
• Do not block the intake or outlet vents.
• Do not use near hot objects, such as a stove. Do not use where the unit may
come into contact with steam.
• Do not use the unit on its side.
• Keep away from products that generate oily residue, such as a deep fryer.
• Do not use detergent to clean the unit.
• Do not operate without a lter.
• Do not wash and reuse the True
HEPA Filter.
• Do not run power cord under carpets or
cover with throw rugs.
• When moving machine, always lift using handle.
2 3
AeraMax-190_870327_RevB_3L_032117.indd 2-3 4/21/17 9:55 AM
PRODUCT SPECIFICATIONS
AIR PURIFIER FEATURES
AeraMax™ 190 Air Purier
Room Area Served 190 sq. ft./18 sq. m. Power Supply AC 120V/60Hz Power Rate Low 6W, Turbo 62W Fan Speed 4 Speeds Display Touch Screen Control Type Auto/Manual/Aera+™
Air Quality Sensor Yes
Filters
1 True HEPA Filter with AeraSafe™ Antimicrobial Treatment 1 Carbon Filter
Carbon Filter
Cleaning System
True HEPA Filter with AeraSafe™ Antimicrobial Treatment
PlasmaTRUE
CADR 126 Smoke/ 129 Dust/ 124 Pollen Color Black
FILTER SPECIFICATIONS
True HEPA Filter
Replacement
with AeraSafe™ Antimicrobial Treatment
Carbon Filter
Replacement
For replacement lters please visit: www.fellowes.com
9287101
9324101
Ultra-Quiet Operation
This Fellowes AeraMax™ Air Purier has a four-speed fan with ultra-quiet operation
that is ideal for 24 hour use.
Easy Maintenance For optimum performance, replace the True HEPA Filter when the HEPA Filter indicator has changed to red, or approximately every 12 months under normal usage conditions. Change the Carbon Filter when the Carbon Filter indicator has changed to red or approximately every 3 months under normal usage conditions.
AeraSmart™ Sensor
This air purier is equipped with an air quality sensor that automatically adjusts the fan speed to keep your air puried. Blue, amber and red lights indicate the purity of your air.
• Four-Speed Setting
From LOW for quiet, energy-efcient operation to TURBO for the most
effective cleaning.
Aera+™ Mode
Designed for peak allergy season
conditions. Increases air turnover rate by 50% versus low fan setting mode to remove even more allergens from your air.
• Replacement Filter Indicator Lights
Indicate when to replace the True HEPA Filter and Carbon Filter,
depending on usage.
FOUR-STAGE PURIFICATION SYSTEM
Removes 99.97% of airborne pollutants.
Carbon Filter
Removes odors and captures large airborne particulates.
• True HEPA Filter
Captures 99.97% of particles as small as 0.3 microns, including ragweed and
other allergens, viruses, germs, dust
mites, mold spores, pet dander and
cigarette smoke.
• AeraSafe™ Antimicrobial Treatment
Built-in protection from the growth of
odor causing bacteria, mildew and fungi on the True HEPA Filter.
• PlasmaTRUE™ Technology
In the nal stage of purication,
Fellowes
®
PlasmaTRUE™ Technology creates an ionized eld to help safely remove airborne pollutants.
TM
Air Inlet
True HEPA Filter with AeraSafe™ Antimicrobial Treatment
Carbon Filter
Drawer
Warning
Any changes or modications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
PlasmaTRUE
Handle
Air Outlet
Louver
Display Panel
Power Plug
4 5
AeraMax-190_870327_RevB_3L_032117.indd 4-5 4/21/17 9:55 AM
AIR PURIFIER SET-UP DISPLAY PANEL
For approximately the rst 4
minutes after turning the unit on,
the auto icon will ash while the unit measures air quality.
NOTE: Follow these instructions for best results.
• Place unit at least 2 feet (½ meter) from the wall.
• Keep unit away from drafty areas.
• Keep curtains away from unit, as they
may interfere with air intake/outlet.
• Place unit on a stable surface with plenty
of air circulation.
1. Remove protective lm from the control panel.
2. Pull out drawer.
3. Remove bag from lters drawer.
5. Fully insert drawer into unit until click is heard.
6. Plug in the power cord to a wall outlet.
7. Turn unit on. Unit will beep.
1. AeraSmart™ SENSOR - Monitors the air quality and
automatically adjusts the fan speed to keep your air puried. Blue, amber and red lights indicate the purity of your air. The unit is set to default to automatic operation when it is rst turned on. If in manual operation, go back to auto at any time by pressing the auto icon.
2. Aera+™ MODE - Designed for peak allergy season conditions.
Increases air turnover rate by 50% versus low fan setting mode to remove even more allergens from your air. Switch to Aera+™
mode by pressing the press the
3. FAN SPEED INDICATOR - Shows current fan speed setting:
low, medium, high or turbo speed.
4. MANUAL FAN SPEED ADJUSTMENT - Tap fan icon to
manually select fan speed.
5. TRUE HEPA FILTER CHANGE INDICATOR - Amber and
red lights indicate when to replace lter. The red indicator light will signal when to replace lter. (Recommended to replace lter every twelve months under normal usage conditions.) For replacement lters, see page 4.
6. CARBON FILTER CHANGE INDICATOR - Amber and red
lights indicate when to replace lter. The red indicator light will signal when to replace lter. (Recommended to replace lter every three months under normal usage conditions.) For replacement lters, see page 4.
7. PlasmaTRUE™ TECHNOLOGY - Creates an ionized eld to
help safely remove airborne pollutants.
icon once more to turn off.
icon. To return to auto operation,
1
2
3
4
5
6
7
8. Adjust louvers to direct air ow.
4. Insert Carbon Filter rst and then True
HEPA Filter.
6 7
AeraMax-190_870327_RevB_3L_032117.indd 6-7 4/21/17 9:55 AM
OPERATION
CARE AND MAINTENANCE
AUTOM ATIC OPER ATION
The unit is set to default to automatic
operation when it is rst turned on. The air purier will automatically sense the amount of impurities in the air, and adjust the fan
speed to keep your air puried.
MANUAL OPERATION
After you turn on the unit, you can switch to
manual operation by tapping the fan icon to manually select fan speed.
LOW, MEDIUM, OR HIGH SETTINGS
These levels are recommended for standard daytime use. HIGH will activate
automatically when sensors detect poor air quality.
LOW
TURBO
The TURBO level, the highest fan speed, can be activated manually for maximum
air purication.
MEDIUM HIGH
AeraSmart™ SENSOR
Air quality indicator shows levels of air quality.
Blue level indicates air is clean.
Amber level indicates air quality is poor.
Red level indicates high level of pollutants
in the air.
Aera+™ MODE
After you turn on the unit, you can
switch to Aera+™ mode by pressing the
Aera+™ mode icon (
to auto operation, press Aera+™ mode
icon (
). To go back
) to turn off.
CLEANING
• Clean unit as necessary by wiping with a
dry, soft cloth; for stubborn stains, use a
warm, damp cloth.
• Do not use volatile uids such as benzene, paint thinner, or scouring powder, as they may damage the
unit surface.
• Keep the unit dry.
Filter Replacement
The replacement lter indicators will signal when to replace the True HEPA Filter and/ or Carbon Filter. The replacement period will vary depending on the hours of use and air quality. However, under normal usage, most True HEPA Filters need to be replaced
annually, and Carbon Filters every three months.
Do not wash and reuse the True HEPA
or Carbon Filters—they will not work
effectively. Only use Fellowes brand AeraMax™ replacement lters.
Replacement Procedure
1. Pull out drawer.
2. Pull out the lters that need to be
changed.
3. Remove any packaging wrap from the new lter(s).
For replacement lter part numbers, see page 4.
WARNING: Before replacing any
lters, make sure to remove the power plug from the wall outlet.