SmartGuard Overview .......................................................... 2
Definition of View Parts......................................................... 3
Installation............................................................................. 4
Step 1 Insert/remove SD card......................................... 4
Step 2 Bulb Installation...................................................4
Step 3 Install Back Up Batteries ..................................... 5
Step 4 Local Time Setting............................................... 5
Step 5 Function Setting................................................... 6
Step 6 Adjusting the Control Knobs ................................ 9
Step 7 Mounting SmartGuard......................................... 9
How to View the Video........................................................ 12
Test SmartGuard................................................................. 12
Troubleshooting..................................................................13
Specification........................................................................ 13
Contents of Package:
No. Item Qty
1 Base Unit (E120CA-1) 1 2 AA Size 1.5V Alkaline Battery 4 3 2GB SD Card 1 4 Screw Pack 1 5 Halogen Bulb 2 6 Operating Instruction Manual 1
1
SmartGuard Overview
Features
z Crystal Clear Color Video Camera (640*480) z Motion Activated Security Light z Capture 20sec/1min/5mins video when motion detected z SD card memory slot, 2GB SD card included z 4 Alert Sounds for selection (2 are recordable) z 4 Scenes satisfy various using scenario z Weather proof, easy to install
Front View
Bottom View
2
Definition of View Parts
Front View Lampshade: Glass for lamp protection.
Microphone: Takes record of your voice/sound. Cam Lens: This is a digital camera lens. PIR Lens: Passive Infrared movement sensor Mounting Hole: For fixing SmartGuard on the wall.
Cover Plate: For mounting SmartGuard & wire covering.
Bottom & Side View
Speaker: Plays recorded/preset sounds Lux Control Knob: For adjusting the ambient lighting level at which the
floodlight will turn on automatically
Time Control Knob: For adjusting the time that the halogen floodlight will stay
on for. LCD Control Display & Set Buttons: Icon display showing settings. Refer to Step 4 for more
instructions on function setting. Battery Cover: For inserting batteries. SD Slot: For inserting a SD memory card.
3
Speaker
Lux Control Knob
Time Control Knob
LCD Control Display & Set Buttons
Side View
SD Slot
Cam Lens
Lampshade
PIR Lens
Cover Plate
Mounting hole
Microphone
Battery Cover
Warm Up
Standby Mode
Installation
Insert/remove SD card
z Unscrew the cover using provided Allen key (FIG. 1a) z Insert provided 2GB SD card or SD card with memory up to 32GB by your choice
into the card slot (FIG. 1b).
z Refit the cover, and fasten the screw clockwise (FIG. 1c).
FIG. 1a FIG. 1b FIG. 1c
Note: If SD card is not inserted properly or not found, SmartGuard will beep 10 seconds once an hour as indication after powering up.
Bulb Installation
z Disconnect the power cord or wall switch z Turn the lampshade anti-clockwise to take off the lampshade (FIG. 2a). z Install G9 halogen bulb to its lamp holder (FIG. 2b). z Reposition the lampshade by turning it clockwise (FIG. 2c).
FIG. 2a FIG. 2b FIG. 2c
4
Install Back Up Batteries
z Unscrew and remove the screw of
Battery Cover.
z Press and release the cover of
battery compartment
z Insert 4 AA size 1.5V alkaline
batteries to the battery spring and make sure polarity (- +) is aligned correctly.
z Refit the battery cover. Note: The batteries power supports most
functions of SmartGuard except lighting.
Local Time Setting
The SmartGuard has a LCD panel with three control knobs: Set, Up and Down.
Once SmartGuard is powered up, it enters PIR warm up time. After 3 seconds, the unit enters standby mode. It implies the unit is ready for function setting.
5
1
2
3
0
.
8
SCREWH EADDIMENSION UNIT:MM
1
2
CAUTION: For security reason, please do not remove the SD card frequently unless an irregular condition has occurred (e.g. detection of an intruder or breaking attempts). To view video, please refer to “Viewing Video” at p12.
CAUTION: (1) Always handle quartz halogen bulb with a soft cloth. Do not touch the bulb
with your bare hand as it will shorten the bulb life.
(2) Do not touch the light while it is in use or still hot. Cool off (about 5 minutes)
before touching it.
Step 1
Step 2
Step 3
Step 4
Year
z Under standby mode, press Set for 3
seconds.
z After
displays on LCD, press Up or Down to select correct year. Year range is between 2010 ~ 2099.
Date & Time
z After year setting, press Set to enter
month & date.
z
displays on LCD, press Up or Down
to select month from Jan to Dec.
z Press Set again to adjust date. z Press Up or Down to adjust date from
1
st
to 31st.
z Press Set again to enter time setting. z Hour ranges from 00 to 23, press Up or
Down to set hour.
z Press Set again to adjust minute, and
press Up or Down to adjust minute from 00 to 59.
Note: If no action is taken within 12 seconds, the LCD returns back to standby mode. Setting is not saved.
Function Setting
Please make sure the SmartGuard is in standby mode before continuing the following procedures.
Scene Mode
Four scene modes are available for selection. Please base on different conditions to select an ideal scene mode.
z Press Set to enter scene 1 (preset mode).
The light turns on indicating SmartGuard is ready for setting.
z Press Up or Down to change scene. z To save the setting, keep press Set until it returns to standby mode.
6
Scene 1: Ideal for away from home (all day detection) No matter it’s day or night, camera, speaker and light are all in operation. Scene 2: Ideal for day to day use
Light isn’t operating in daytime while speaker isn’t operating at night.
Scene 3: Ideal for a place of business
All functions are operating at night while only camera is operating in the daytime.
Scene 4: Ideal for using as a working light
All functions are off except lighting is operating at night. The light turns on if PIR sensor detects a motion.
Camera Speaker Light
Day
Scene 1
Night
Day
Scene 2
Night
Day
Scene 3
Night
Day
Scene 4
Night
Note: The symbol √ implies the function is ON. The cutting point between day and night is the LUX level you set. For example, if LUX level is set at 150 LUX, day is defined when the ambient light is brighter than 150 LUX whereas night is defined when the ambient light falls below 150 LUX. Please refer to p.9 for LUX adjustment.
Audio Warning
Four warning sounds are available for selection.
z Under scene mode, press Set once to enter audio warning 1 (preset mode). z The light turns on indicating SmartGuard is ready for setting. z Press Up or Down to change audio warning.
Audio warning 1: Alarm Sound Audio warning 2: Dog Sound Audio warning 3 & 4: Empty (for user recording)
Audio warning 5: Mute Mode
8
7
Mute Mode
Audio Warning 1
Step 5
To record your own alert sound/voice:
z Select audio warning 3 or 4. z Press Set for 3 seconds, the light flashes
once implies the SmartGuard is ready for recording.
z Wait for 5 seconds, LCD occurs with
REC, the recording starts.
z After that, LCD returns back to audio
warning 3 or 4. The recorded sound will be played for verification.
Note: The recording time is 10 seconds. If video is in the middle of recording, the setting of audio warning will not be available until video recording is finished.
PIR Sensitivity
Four levels of PIR sensitivities are available for selection to achieve an optimal performance of PIR detection.
z Under audio warning mode, press Set
once to enter PIR sensitivity 1 (preset mode).
z The light turns on indicating SmartGuard is ready for setting. z Press Up or Down to change PIR sensitivity.
Note: PIR sensitivity 1 is the highest sensitivity level while PIR sensitivity 4 is the lowest sensitivity level.
ID Code Learning (for remote controller only)
This setting is equipped for remote controller. Please note the remote controller is sold separately.
8
Adjusting the Control Knobs
Time Control
The TIME adjustment controls the video recording time and amount of TIME light stays on after the motion is detected.
z Set the amount of TIME by sliding the knob to 20sec, 1
or 5 minutes.
Note: Light stays on time might be extended as long as a motion is detected.
Lux Adjustment
The LUX adjustment determines at what light level the light starts operating.
z Set the LUX control knob to any position between sun
(200LUX) and moon
(20LUX).
z Set scene mode to Scene 2 (refer to p.6 for scene setting). z If ambient light falls below the set LUX level, the light will start operating. z Adjust LUX control knob slightly until desired LUX level is found.
Mounting SmartGuard
Safety Precautions
z Do not install SmartGuard when it
is raining.
z Be sure to switch off power source
before installing.
z When mounting on the wall, it can
be installed only vertically, not horizontally.
VERTICAL HORIZONTAL
9
Step 6
Step 7
TOP VIEW
0
12
2
4
8
4
0
12
8
84
SIDE VIEW
12
UNIT:m
1
1
0
°
Choose a Location
Before mounting the SmartGuard, please consider and select a location for the unit based on the coverage angles as shown on the right and the following conditions:
z For the best results, fix the unit on a solid surface,
2~2.5m above the ground.
z Avoid aiming the unit at pools, heating vents, air
conditioners or objects which may change temperature rapidly.
z Do not allow sunlight to fall directly on the front of
unit.
z Try to avoid pointing the unit at trees or shrubs or
where the motion of pets may be detected.
z Prior to mounting the unit, remember to position the
motion sensor so that a moving object cuts “across” its beams, not directly towards them. (FIG. 3a, p.10).
Install a wall switch adjacent to the power source (FIG. 3b). This will help you operate SmartGuard with ease.
10
Wire SmartGuard
z Switch off the power source or wall switch. z Align the mounting straps to the junction box with
the holes. Secure with mounting screws.
z Twist the junction box wires with fixture wires
together as shown below. Secure with provided wire nuts.
z Align the mounting holes to the mounting
straps, secure with two provided screws.
z Switch on the power source or wall switch.
11
IMPORTANT
Some local building codes may require installation of this product by a qualified electrician.
Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods.
Maintenance or repairing work such as replacing current fuse shall be done by a qualified electrician or technician.
Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.
CAUTION: THIS EQUIPMENT MUST NOT BE MOUNTED ON AN OUTLET BOX WHICH IS SUPPORTED BY A BAR HANGER or equivalent (NE PAS MONTER CET ÉQUIPEMENT SUR UNE BOÎTE DE SORTIE FIXÉE À UNE BARRE DE SUSPENSION or equivalent).
MORE SENSITIVE
SENSOR
LESSSENSITIVE
SENSOR
SENSITIVITY TO MOTION
FIG. 3a
Yellow/Green to Yellow/Green (earth)
Wire Nuts
Blue to Blue (neutral)
Brown to Brown (live)
Mounting Straps
Junction Box
FIG. 3b
N
L
WALL SWITCH
AC POWER
How to View the Video
z Open the cover of SD slot. z Push in the SD memory card and it will spring out, carefully
remove it from your SmartGuard.
z The recorded file will be saved in .asf format under the
path LIGHT\YMD\time+serial no.asf. Below is an example of a self generated file name:
17075600
Note: Oldest images are deleted and overwritten as the card reaches capacity to ensure records of recent events are always available.
Test SmartGuard
It It is recommended to test the SmartGuard after the above steps are completed to ensure your SmartGuard can reach its optimal performance. The following test is based upon setting of Scene 1 with time control set in 20 seconds and Lux control switched to the dusk position.
z Either day or night, walk into and move slowly around the protected area. Once
the PIR detector senses movements, alert sound is on with the light turn on and camera records for 20 seconds.
z Check the video record. The length of playing time is 20 seconds after the
camera detects a movement plus approx. 4 to 12 seconds of pre-record time ( pre-record image allows you to trace what’s happening before a movement has been detected).
z If recorded images are blurred at night, check the position of camera lens. Turn
the lens down to avoid taking sky as background. Check if floodlight is spotting on reflective objects. Move reflective objects or adjust mounting position of the SmartGuard if it is required.
12
Troubleshooting
Light does not turn on:
z Confirm that you have made a correct “wiring connection”. z Make sure that the bulb has not burned out and is installed correctly.
Warning Sound is on after powering up: z SD card is not inserted. PIR and LUX is not working: z Do not allow sunlight to fall directly on to the front of the unit. Warning sound and video recording is not on:
z They are on only when the unit is triggered. z Make sure the unit is not on Scene 4. z Please re-power the unit
Filmed videos can’t be saved into SD card: z Damage of the videos might be caused by inappropriate retrieval/insertion of
SD card; ensure the unit is powered off before the action is taken. No action is taken after scene changing: z Under video recording mode, the scene changing will not happen until PIR
triggering time is finished (e.g. if PIR triggering time is set to 5 mins, the scene
changing will be taken 5 mins later). Video and sound recording is not executing: z The function is disabled if the unit is set to scene 4. The taken images of people are blurred during the night: z Avoid taking images with sky as background; turn the camera lens down if it is
the case. z Try not to spot the light on reflective objects; the reflection of light could cause
blurred images.
Specification
Power Requirement
120V~ 60Hz or 1.5V AA alkaline battery x 4 (for SD card &
camera only) Lighting Load Max. 60W x 2 G9 Halogen Bulb PIR Detection Angle
Up to 150° PIR Detection Distance
Up to 12M under 28°C Protection Class I Protection Degree IP54 for Europe. Suitable for wet locations for USA
Swiveling Angle
Sensor Part: Horizontal 90° (45° left, right), Vertical 30°
(downward) Mounting Height 2 to 2.5M Time Adjustment 20 secs/1 min /5 mins Lux Adjustment Y es Warm Up T ime About 60 second Operating Temperature Range
-10°C ~ 40°C. 20~85% relative humidity, non-condensation.
*Specifications are subject to change without prior notice.
13
Hour
Minute
Seconds
Serial no.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC rules. Operation is subj ect to the following two conditions.
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interf erence that may cause
undesired operation.
Per FCC 15.21, you are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.
IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into
the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obliga ted to take back your
old appliance for disposal at least for free of charge.