MODEL 73995
LED LUMINAIRE - IMPORTANT SAFETY INSTRUCTIONS
LIMITED WARRANTY
This product is warranted to be free from defects in workmanship and
materials for up to 3 years from date of purchase. If it fails to do so, please
contact Feit Electric at info@feit.com or call 1-866 326-BULB (2852) for
instructions on replacement. Do not return the product to the store.

MODEL 73995
LED LUMINAIRE - IMPORTANT SAFETY INSTRUCTIONS
Mounting Hardware Included
1. Remove fixture components and parts
pack. Check that all parts are included.
Optional Mounting Arm available (sold
separately)
Turn OFF Power at circuit breaker
!
box. CAUTION:Do not rely on wall
switch alone to turn off power
Note: NOT suitable for use with
dimmers, motion sensors or other
remote devices.
Fixture Mounting
Note: Hardware included for mounting to
wood surfaces only. Ensure that fixture is
mounted onto structurally sound surface
that will support the fixture.
(3)Photocontrol
(1)Housing Assembly
(4)2” Screws
(9)Handle
Fig 1
(7)M6 Screws
(8)Cover Plate
(6)M6 Nuts
2. Using the template on the box, mark
mounting holes locations and drill 5/32”
diameter pilot holes. See Fig 2
CAUTION: WIRING AND FIXTURE
OPERATION Make sure power is
turned off.
3. Install the three 2” Screws (4) (or
other appropriate mounting hardware) into
the predrilled hole on top and back the
Screw out. This will leave the hole threaded
and make installation easier. See Fig 1
4. Unscrew the M6 Screws (7) from handle.
remover the cover plate (8).
5. Assemble the handle to the housing
assembly, secure the housing assembly to
the wall with 2” Screws.
6. Pass fixture wires into two openings on
cover plate, feed the wires into outside
conduit. Reassemble the cover plate to
handle with M6 Screws (7) and unts (6).
For proper connection, place wire nut
over wires and twist clockwise until
tight.
7. Use conduit and fittings (not supplied)
to connect between the cover plate and
a properly installed and grounded UL
listed junction box (not supplied).
8. Connect supply wires
Use Wire Nuts (5) to connect the black
fixture wire to the black power supply
wire and the white fixture wire to the
white (neutral) supply wire.
9. Install the LED bulb (2).
10. Turn on electricity at fuse or circuit
breaker box and verity success of
installation. Note: Test fixture at night or
block photocontrol.
(2)LED Bulb
Conduit & Fitting
(Not Supplied)
(5)Wire Nuts
FIXTURE PACKING LIST
Description Quantity
(1)Housing Assembly.....................................
(2)LED Bulb...................................................
(3)Photocontrol..............................................
(4)2” Screws...................................................
(5)Wire Nuts...................................................
(6)M6 Nuts ....................................................
(7)M6 Screws ................................................
(8)
Cover Plate ..................................................
(9)Handle........................................................
1.25”(32mm)
1
1
1
3
3
2
2
1
1
Fig 2
2.35”(59.7mm)

MODEL 73995
LED LUMINAIRE - IMPORTANT SAFETY INSTRUCTIONS
Pole Mount Option (Fig 3)
1. Mount arm assembly in desired location
firmly.
2. Unscrew the M6 Screws (7) from handle,
remove the cover plate (8), assemble the
handle to the housing assembly.
3. Pass fixture wires into one opening on
vertical cover plate (8). Reassemble the
cover plate (8) to handle with M6 Screws
(7) and nuts (6).
4. Feed supply wires up through mounting
arm, use wire nuts (5) to connect neutral,
line and grounding wires (black/white/
green-yellow). Push the wires and
connectors into arm.
5. Move the housing assembly toward arm
until there is no gap between the arm and
the vertical cover plate (8).
6. Secure the M6 Screws (7) and nuts (6)
of cover plate (8) firmly.
7. Install the LED bulb (2).
(3)Photocontrol
(1)Housing Assembly
(4)2” Screws
(9)Handle
Fig 3
(7)M6 Screws
(5)Wire Nuts
(8)Cover Plate
(6)M6 Nuts
Recommend use the diameter 1.5”
(2)LED Bulb
Trouble Shooting Guide
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem.
Verify that power is turned on at switch and breaker.
Verify that fixture is wired properly.
Verify that line voltage is correct.
Test if Photocontrol works properly.
The photocontrol in this fixture is designed to turn on fixture light at low light levels.
If light does not come on or stays on:
Test if Photocontrol works properly:
Cover Photocontrol - Light should come on.
Shine a flashlight into Photocontrol - Light should go off.
If fixture cycles on and off:
Light reflecting back off any surrounding surfaces enters the photocontrol.
To correct problem, reposition the fixture or eliminate reflective surface.