Feiss OUTDOOR FIXTURE User Manual

FIXTURE INSTALLATION INSTRUCTIONS
(OUTDOOR-DOUBLE MOUNTING STRAP MACHINE SCREW INSTALLATION) 2018E REV.
Outlet Box Machine Screws
Mounting Strap
Outlet Box Mounting Screws
Lock Nuts
Fixture
Cap Nuts
Silicone Caulking
TURN OFF POWER AT THE MAIN FUSE OR CIRCUIT BREAKER BOX BEFORE STARTING INSTALLATION
1) If you are replacing an existing fixture, disconnect and
remove the old fixture. Expose the supply wiring from the outlet box.
mounting strap from he green ground screw. Lock the machine screws into place with lock nuts.
3) Fasten the mounting strap to the outlet box using the two
screws supplied with the outlet box.
4) Spread the electrical wires so that the black wires are on
one side of the outlet box and the white wires are on the other side.
5) Grounding instructions:  A) On fixtures where mounting strap is provided with a
green ground screw and two raised dimples. Wrap ground wire from outlet box around green ground screw and tighten.
B) On fixtures where mounting strap is provided with a
green ground wire attached. Connect mounting strap ground wire to ground wire from outlet box with wire connector (not provided).
If fixture is provided with ground wire, connect fixture
ground wire to ground wire from outlet box with wire connector (not provided); after following he above steps.
© FEISS INDUSTRIES
Never connect ground wire to black or white power
supply wires.
6) To make electrical connections: Connect the white wire (s)
from the fixture to the white wire of the outlet box. Connect the black wire (s) from the fixture to the black wire of the outlet box. NOTE: Black outlet box wire may be red, round & smooth and/or have copper conductor. White outlet box wire may be square & ridged and/or have a silver conductor.
7) Place fixture against mounting surface allowing the
machine screws to pass through the fixture cover plate. Secure with cap nuts.
8) Instructions for Mounting Fixture Outdoors and/ or in Wet
Location:
A) Mounting surface should be clean, dry, flat and 1/4"
larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16" should be corrected as required.
 B) With silicone caulking compound, caulk completely
around where back of canopy meets with the wall surface to prevent water from seeping into outlet box.
M U R R A Y F E I S S