![](/html/d1/d1c6/d1c634d8435087f505a11317d1326d1a16f979387f07ace1777d693a585ef41e/bg1.png)
Assembly Instructions For
Threaded Pipe
Outlet Box
Mounting Screw
Crown
Bulb (not included)
Outlet Box
Hex Nut
Lock Washer
Coupler
Center Pipe
FM276
Mounting Strap
Supply Wire
Supply
Ground Wire
Fixture Wire
Fixture
Ground Wire
Socket
(E) 10/07
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE OR
CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Carefully unpack and identify all parts before assembly. Bulb
not included.
1. Attach mounting bar securely to ceiling junction box with
two machine screws (supplied with junction box) through
slot at each end of mounting bar.
Note: mounting bar should be installed with "GND" imprint
and/or two dimples facing down.
2. Fasten one hex nut about 3/4" (19 mm) down from one end
of threaded pipe. Then screw same end of threaded pipe into
center hole in mounting bar. At this point test install the
crown onto ceiling through this threaded pipe and make
certain 3/8" (10 mm) of pipe protrude below. If not, then
adjust the threaded pipe location by screwing up or down
accordingly. Once correct threaded pipe location has been
adjusted, remove crown and tighten hex nut against mounting
bar. Make certain not to spin threaded pipe during tightening.
3. Spread the electrical wires so that the black wires are on one
side of the outlet box and the white wires are on the other
side.
4. Electrical connections:
Connect the white wire from the fixture to the white wire of
the outlet box. Connect the black wire from the fixture to
the black wire of the outlet box.
NOTE: Black outlet box wire may be red, round & smooth
and/or have copper conductor. White outlet box wire may be
square & ridged and/or have a silver conductor.
Finial
Shade
Frame
5. Grounding Connection:
Connect fixture ground wire (without insulation) to ground
wire from outlet box (usually with green insulation) with
wire connector (not provided).
IMPORTANT: Never connect ground wire to black or white
power supply wires.
6. Place crown thru top threaded pipe so that it sits flush
against ceiling. Be sure all wires are inside crown. Secure
crown to ceiling by fastening lock washer and coupler onto
top threaded pipe.
Note: Coupler must turn at least 3 times, if it does not you
must remove coupler and lengthen threaded pipe accordingly.
7. Install bulb (not included). See relamping label located at
socket area for type and maximum allowed wattage.
8. Install the center pipe by screwing onto bottom of main
frame. Note correct position of center pipe at illustration.
9. Place shade carefully inside of frame. Then grabbing firmly
onto the frame, install onto crown by fastening with finial.