Feiss FM273 User Manual

Assembly Instructions For
Supply Wire
Fixture Wire
Socket
FM271, FM272, FM273
IMPORTANT
INSTALLATION
Outlet Box
Long Screw
Mounting Plate
Outlet Box Mounting Screw
Supply Ground Wire
Fixture Ground Wire
TURN OFF THE POWER AT THE MAIN FUSE OR
CIRCUIT BREAKER BOX BEFORE STARTING
Carefully unpack and identify all parts before assembly.
Bulb not included.
1. Mounting Plate installation: A. Install long screws onto mounting plate by screwing from
B. Leave about 3/4" (19 mm) of thread exposed then lock in
place by fastening with hex nuts from opposite side.
C. Pass electrical wires from outlet box through center hole
in mounting plate.
D. Fasten the mounting plate onto outlet box using two
screws supplied with the outlet box.
E. At this point, test install crown onto ceiling and make
certain about 3/16" (5 mm) of screw threads are protruding below crown surface. If not, then adjust screw location by loosening hex nuts and screwing up or down accordingly.
F. Once correct screw location has been adjusted, remove
crown and tighten hex nuts. Make certain not to spin screws during tightening.
G. Spread the electrical wires so that the black wires are on
one side of the outlet box and the white wires are on the other side.
(E) 10/07
Cap Nut
Crown
Bulb (not included)
Shade
2. Grounding Connection: This fixture is provided with a ground wire. Connect fixture
ground wire to ground wire from outlet box with wire connector (not provided).
Never connect ground wire to black or white power
supply wires.
3. Electrical connections: Connect the white wire(s) from the fixture to the white wire
of the outlet box. Connect the black wire(s) from the fixture to the black wire of the outlet box. NOTE: Black outlet box wire may be red, round & smooth and/or have copper conductor. White outlet box wire may be square & ridged and/ or have a silver conductor.
4. While gently tucking all wires inside, install crown onto the outlet box by fastening with cap nuts onto protruding screws.
5. Install bulb (not included). See relamping label located at socket area for type and maximum allowed wattage.
6. Install shade onto crown by turning in clockwise direction. IMPORTANT: MAKE CERTAIN SHADE IS FIRMLY LOCKED INTO CROWN.