Copyright 2015 by FEIG ELECTRONIC GmbHLange Straße 4
D-35781 Weilburg
GBR
Tel.: +49 6471 3109-0
www.feig.de
Version: 2015-09-14 VEK MNE1 / VEK MNE2
This edition renders all previous editions invalid.
The information in this document is subject to change without notice.
Without FEIG ELECTRONIC’s prior written permission, it is not permitted to produce complete or partial copies and reproductions of this manual and translations into other languages. It is also prohibited to store total this manual on modern information carriers for manipulation purpose in data processing systems
The compilation of the information in this document is based on our best knowledge and belief. FEIG
ELECTRONIC GmbH accepts no responsibility for the correctness and completeness of the information in
this manual. FEIG ELECTRONIC GmbH will not be held liable for consequential damages arising as the result of incorrect or incomplete information.
Since it is impossible to avoid mistakes despite our sincerest efforts, we are always grateful if these are
pointed out.
The installation recommendations provided in this document are based on favorable conditions. FEIG
ELECTRONIC does not provide any warranty for the proper operation of the traffic detector in foreign system
environments.
FEIG ELECTRONIC GmbH does not warrant the material described herein to be free of third party industrial
property rights. With this document, FEIG ELECTRONIC GmbH does not issue any licenses to its own or
others patent rights or industrial property rights.
Warranty claims against FEIG ELECTRONIC GmbH can only be made by the purchaser and are not transferable. FEIG ELECTRONIC GmbH’s warranty obligation extends only to products supplied by FEIG
ELECTRONIC GmbH. The warranty excludes any liabilities for the entire system.
The description of the products, their application, capabilities and performance shall not be considered as
warranted properties and are subject to technical change.
Before using the traffic detector, please read the operating and safety instructions with care!
General information about this document
Language of the original instructions: DeutschThe following characters are used in the functional description to point out
the different danger zones and useful hints.
indicates that a potential risk to persons exists, if the procedure is not carried out as described.
indicates that the controller is at risk of being damaged.
indicates information that is important for the operation of the device.
indicates useful information that is relevant but not essential to the utilization of the device.
2 09/2015 FEIG ELECTRONIC GmbH
Manual VEK MNE1 / VEK MNE2
TABLE OF CONTENTS
1 Safety Precautions and Warning Notes ................................................................................................. 4
10 Elements on the Front ........................................................................................................................... 11
10.1 LED Display ....................................................................................................................................... 11
10.4 USB Socket ....................................................................................................................................... 13
11.1 Sensitivity, On Threshold .................................................................................................................. 14
11.2 Hysteresis, Off Threshold .................................................................................................................. 15
11.3 Frequency ......................................................................................................................................... 16
11.4 Hold Time .......................................................................................................................................... 16
11.5 Output, Signal Shape ........................................................................................................................ 17
11.6 Invert Output Signal Behavior ........................................................................................................... 17
11.10 Timing of Output Signals (On Delay, Off Delay, min. Duration) ........................................................ 18
11.11 Direction Detection (Dir. Mode, Direction Mode) .............................................................................. 19
11.12 Direction Logic ................................................................................................................................... 19
• The device must only be used for the purpose intended by the manufacturer.
• Store the operating instructions in an accessible location and pass it on to every user.
• Unauthorized modifications and the use of spare parts and accessories, which are not sold or recom-
mended by the manufacturer of the equipment, can result in fires, electric shock and injury. Therefore,
such measures lead to an exclusion of liability and the manufacturer will not accept liabilities.
• For the device, the manufacturer's warranty provisions in force at the time of purchase are valid. No liability is assumed for improper or wrong manuals or automatic adjustment of parameters of a unit or the improper use of a device.
• Do not open the enclosure.
• Repairs shall only be carried out by the manufacturer.
• The power source used must meet the requirements for SELV circuits and current limited power sources
in accordance with EN 60950-1.
• Connecting, commissioning, maintenance, testing and adjustment work on the traffic detector must be
carried out by qualified electricians with the relevant accident prevention training.
• Observe valid VDE regulations when handling devices that are exposed to electrical voltage. In particular,
but not limited to, these are VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711, VDE 0860, VDE 0105, as
well as the fire and accident prevention regulations BGV A3 (previously VBG 4).
• The fact that an operational indicator turns off is no indication that the unit was disconnected from the
power supply and that it is de-energized.
• All work on the unit and its installation must be carried out in accordance with the national electrical codes
and local regulations.
• It is the responsibility of users or installers to make sure that the equipment is installed and connected in
accordance with recognized engineering practice in the country of installation and relevant local regulations. Particular attention must be focused on cable dimensions, fuses, grounding, shutdown, isolation,
insulation monitoring and overcurrent protection.
• The combined operation of extra low and low voltage on both outputs of the relays is not permitted!
• The round plug corresponds to the basic insulation properties. If the relay contacts carry voltages > 48
VAC/DC as well as for all -R230 versions, the isolation of all connecting cables of the 11-pin round plug
must be designed for 230 V AC.
• The device must not be used as a safety unit in accordance with the Machinery Directive 2006/42 / EC,
the Construction Products Directive 89/106 / EEC or any other safety regulation. In systems with potential
risks, additional safety equipment is required!
2 Maintenance
The unit does not contain parts that need servicing by the installer or user.
Do not open the enclosure.
4 09/2015 FEIG ELECTRONIC GmbH
Manual VEK MNE1 / VEK MNE2
3 Functional Description
The traffic detectors VEK MNE1 and VEK MNE2 are systems for the inductive recognition of vehicles that
must be installed in control cabinets.
• Compact plastic enclosure to be mounted in the control cabinet on sockets on DIN rails
• Automatic adjustment of the system after it is turned on
• Continuous readjustment of frequency drifts to neutralize environmental influences
• Sensitivity independent of loop inductance
• Fixed dwell times regardless of the degree of coverage of loops
• Frequency adjustment
• Direction sensing (only on VEK MNE2)
• Multiplexing method to avoid mutual interference of the loop channels
• LED indication of the loop conditions
• Galvanic isolation between loops and electronics
• Relay outputs
• USB-interface for the diagnosis and other adjustments
Adjustment options:
• Adjustments by means of a 8-pole DIP-switch and a 4-pole DIP-switch (only on VEK MNE2)
• two frequency levels
• Threshold of each channel in 255 steps (via 4 stage DIP-switch)
• Off hysteresis of 20-80% per channel
• Hold time 1-255 minutes and infinite per channel (via DIP-switch 5 minutes and infinite)
• Detector channels can be turned off
• Output adjustable as presence, pulse, direction signal (only on VEK MNE2) or loop failure
GBR
3.1 Vehicle Detection System
An LC oscillator determines whether a metallic vehicle is located in the loop region or not. The output of the
channel is controlled in accordance with the selected output function.
3.2 Adjustment
The adjustment of the loop channels is carried out after turning on the detector or by pressing the front button for about 1 s. After a power failure, an automatic adjustment is carried out only when the operating voltage has been interrupted for a period of at least 0.5 s. The adjustment time is approximately 1 s, if the loop is
not crossed by vehicles during this time.
Extended adjustment periods also result by external influences on the loop frequency, their causes must be
identified and eliminated.
3.3 Output Options
Depending on the selected output function, the outputs provide a presence signal, pulse signal, direction
signal (only on VEK MNE2) or loop error. The adjustment of the pulse signal can also be used to select
whether an output takes place when driving on or leaving the loop.
In addition to the inversion of the output signals, both outputs may be turned on or off individually and permanently.
3.4 Multiplex-Procedure
The connected induction loops on the 2-channel traffic detector VEK MNE2 are turned on and off in rapid
succession. Current always only flows through one loop. Mutual influence of the loops of a detector is thus
prevented. Both loops connected to a detector can operate at the same frequency.
FEIG ELECTRONIC GmbH 09/2015 5
Manual
earview
VEKMNE1/VEKMNE2
FEIGELECTRONICGmbH
Frontview(VEKMNE2)
4 Enclosure
GBR
Side view
6
R
: Pins on the 11-pin round plug
09/2015
Manual VEK MNE1 / VEK MNE2
5 Technical Specifications
Enclosure: Plastic enclosure ABS, blue
Round plug, 11-pin PPO, fiberglass-reinforced, black
Supply voltage -R230: 100-240 V AC, 50-60 Hz
-R24: 10-30 V AC/DC
SELV, power source with limited output (EN 60950-1)
Power consumption typ. 500 mW, max. 2 W
Protection class -R230: II
Ambient temperature -37 °C to +70 °C
Storage temperature -40 °C to +85 °C
Relative humidity max. 95 % non-condensing
Loop inductance range: 20-700 uH
Recommended loop inductance: 100-300 uH
Frequency of operation 30-130 kHz