With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.
OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
®
I-CODE
Bluetooth
is a registered trademark of Philips Electronics N.V.
®
is a registered trademark of Bluetooth SIG Inc.
FEIG ELECTRONIC GmbHPage 2 of 18M50800-0e-ID-B.doc
OBID i-scan
®
InstallationID ISC.PRH101
Contents
1. Safety Instructions / Warning - Read before start-up !4
2. Performance Features of the ID ISC.PRH1015
2.1. Performance features .........................................................................................................5
2.2. Available Reader-Types......................................................................................................5
3. Control and Display Elements6
3.1. Signal buzzer .......................................................................................................................6
7.2. Scope of delivery...............................................................................................................18
FEIG ELECTRONIC GmbHPage 3 of 18M50800-0e-ID-B.doc
OBID i-scan
®
InstallationID ISC.PRH101
1. Safety Instructions / Warning - Read before start-up !
• The device may only be used for the intended purpose designed by for the manufacturer.
• The operation manual should be conveniently kept available at all times for each user.
• Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
• Repairs may only be executed by the manufacturer.
• Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
• Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
• When working on devices the valid safety regulations must be observed.
• Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker.
FEIG ELECTRONIC GmbHPage 4 of 18M50800-0e-ID-B.doc
OBID i-scan
®
InstallationID ISC.PRH101
2. Performance Features of the ID ISC.PRH101
2.1. Performance features
The ID ISC.PRH101 are devices for contactless data exchange with common Transponder according ISO 15693. The readers have an internal antenna and will be delivered ready for connection. The device is designed as a handheld.
An anti-collision function enables simultaneous reading of several transponders per second.
The Reader electronic is fitted in a plastic housing with a protection class IP30.
The Reader ID ISC.PRH101-A has an asynchronous RS232 interface, the ID ISC.PRH101-B has
an Bluetooth interface and the ID ISC.PRH101-USB has an USB interface.
2.2. Available Reader-Types
Following Reader-Types are available at present:
Reader-TypesDescription
ID ISC.PRH101-Aasynchronous RS232 interface with internal antenna and
voltage supply by means of external 5 VDC power supply.
ID ISC.PRH101-BBluetooth interface with internal antenna and
voltage supply by means of 4 rechargeable Mignon AA batteries
ID ISC.PRH100-USBUSB interface with internal antenna and
voltage supply by means of USB-High Powered Interface
Tabelle 1: Reader-Types
FEIG ELECTRONIC GmbHPage 5 of 18M50800-0e-ID-B.doc
OBID i-scan
®
3. Control and Display Elements
LED
InstallationID ISC.PRH101
Scan-button
Fig. 1: Control and Display Elements
3.1. Signal buzzer
The signal buzzer can be configured by the software.
In the standard configuration the signal buzzer will be active if a Transponder is recognised.
3.2. Scan - button
The switch of the reader can be configured by the software.
In the standard configuration the serial number of the Transponder is read and is sent to the host
after pressing the scan - button.