FeelTech FY2300 series User Manual

FeelTech
FY2300 Series Fully Numerical Control
Dual Channel Function/Arbitrary Waveform Generator
User’s Manual
Rev1.3 January,2016
FeelTech
Copyright
© 2015 FeelTech Technology Co. Ltd. All Rights Reserved.
Trademark Information
FeelTech is a registered trademark of FeelTech Technology Co. Ltd.
Declaration
FeelTech reserves the right to modify or change parts of or all the
specifications and pricing policies at company’s sole decision.
Information in this publication replaces all previously corresponding material.
FeelTech shall not be liable for losses caused by either incidental or
consequential in connection with the furnishing, use or performance of this
manual as well as any information contained.
Any part of this document is forbidden to be copied or photocopied or
rearranged without prior written approval of FeelTech
Contact Us
If you have any problem or requirement when using our products or this
manual, please contact FeelTech.
Tel0086 371 68997005 E-mailfeeltech@126.com
Websitewww.feeltech.net
FY2300 Series User’s Manual I
FeelTech
Contents
Guaranty and Declaration Brief Introduction Quick Start
........................................................................................................................
............................................................................................................
..............................................................................................
General Inspection.....................................................................................................4
Front Panel Overview Right Panel Overview Left Panel Overview Power On and Inspection User Interface
...........................................................................................................
Appearance and Dimensions
................................................................................................
................................................................................................
..................................................................................................
.........................................................................................
.................................................................................
10 12
Front Panel Operations...............................................................................................14
Waveform Output
Select Output Channel........................................................................................................14
Select Waveform..................................................................................................................15
Set Frequency......................................................................................................................16
Set Amplitude....................................................................................................................... 17
Set Offset.............................................................................................................................. 19
Set Duty Cycle (Square).....................................................................................................20
Set Phase..............................................................................................................................21
.....................................................................................................
14
I 1 4
5 7 8 9
Enable Output...................................................................................................................... 22
ExampleOutput Sine Waveform....................................................................................23
Generate a Burst Waveform.................................................................................. 25
Frequency Meter/Counter...................................................................................... 26
Enable the Counter............................................................................................................. 26
Set the Counter....................................................................................................................27
Sweep
........................................................................................................................
Sweep Object....................................................................................................................... 28
Sweep Start Position...........................................................................................................29
Sweep End Position............................................................................................................ 30
Sweep Time..........................................................................................................................31
Sweep Type..........................................................................................................................32
Enable Sweep Function......................................................................................................33
28
System Configuration and Auxiliary Functions................................................... 34
Save and Load.....................................................................................................................35
Synchronization................................................................................................................... 36
Configuration........................................................................................................................ 37
Uplink..................................................................................................................................... 38
Troubleshooting............................................................................................................39
Technical Specification...............................................................................................40
Appendix.........................................................................................................................43
II FY2300 Series User’s Manual
FeelTech
Adopt DDS technology to generate accurate, stable signal with low distortion.Portable design with top grade aluminum alloy shell. Use DC5V power
Brief Introduction
This manual applies to each model of FY2300 series Function/Arbitrary
Waveform Signal Generator. The “25M” of the Model Number “FY2300-25M
indicates the Sine wave maximum output frequency is up to 25MHz.
FY2300 series Dual Channel Function/Arbitrary Waveform Generator is a
multifunctional signal generator product integrating Function Signal Generator,
Arbitrary Waveform Generator, Pulse Signal Generator, Noise Signal Generator,
Counter and Frequency Meter with excellent cost performance. This instrument
adopts large scale CMOS integrated circuit and high speed MCU microprocessor.
The internal circuit uses SPXO as the basic standard to guarantee the stability of
signals. Surface mounting technology improves interference immunity and
operational life span.
This instrument has double channels can output 31 preseted DDS signals
including Sine, Square, Triangle(Ramp), Rise Sawtooth, Fall Sawtooth, Lorenz
Pulse, Multitone, Noise, Cardiogram, Trapezoidal Pulse, Sinc Pulse, Narrow
Pulse, Gauss White Noise, AM, FM, Step and user-defined waveform. It can also
output TTL electric level. Both channels are completely independent
It has friendly human-machine mutual interface. 2.4 inch TFT Color LCD with
320×240 resolution can display all the parameters of both channels and current
functions of all buttons . Shortcut keys simplify all complicated operations and
save time. Users can be proficient after several minutes practice.
The advantages of this instrument in signal generating, waveform sweeping,
parameter measurement and other fields, make it to be the ideal equipment for
electronic engineers, laboratories, industry producing line, university, R&D
institutes and so on.
Main Features:
FY2300 Series User’s Manual 1
FeelTech
2.4 inch TFT Color LCD with 320×240 resolution can display all the
Frequency output of Sine wave can be up to 25MHz. 200MSa/s sampling rate.
Complete independent dual channels can work at same time and phase
Following function allows users to synchronize all or partial parameters of
Two instruments or more can be synchronized by TTL_IO interface.Various Waveform:
Sine
Square
Triangle/Ramp
Rise Sawtooth
Fall Sawtooth
Lorenz Pulse
Multitone
Noise
Electrocardiogram (ECG)
Trapezoidal Pulse
Sinc Pulse
Narrow Pulse
Gauss White Noise
Step Triangle
Positive Step
Inverse Step
Positive Exponent
Inverse Exponent
Positive Falling Exponent
Inverse Falling Exponent
Positive Logarithm
Inverse Logarithm
Positive Falling Logarithm
Inverse Falling Logarithm
Linear FM
AM
FM
Positive Half Wave
Negative Half Wave
Positive Half Wave
Rectification
Negative Half Wave
Rectification
User-defined waveform
It has 16 positions for saving user-defined waveform. Waveform Length of
High frequency precision up to 10-6orders of magnitude.
Full range of 1μHz frequency resolution.
Minimum amplitude resolution can be up to 1 mV.
adopter or 5V portable power for power supply.
parameters of both channels and current functions of all buttons .
12 bits vertical resolution.
difference is adjustable.
CH2 to CH1.
each one is 2048 and vertical resolution is 12 bits.
2 FY2300 Series User’s Manual
FeelTech
Duty cycle of each channel can be adjusted separately. Precision can be
Direct digital Setting covering full range of frequency without grading.Sweep Function: It can sweep 4 properties of signals including frequency,
It has pulse train burst output function. There has Manual Trigger, internal
-10V~+10V DC Offset function. Resolution 0.01V.
Digital signal output function can output any 0~10V CMOS electric level.Save function: It can save 20 sets user-set parameters and can be loaded at
100M Frequency meter function: It can measure frequency, period, pulse
Counter Function: It has 2 coupling measure modes including DC coupling
All parameters can be calibrated by internal program.Powerful arbitrary waveform edit function: Users can download arbitrary
Powerful communicating function. All functions can be controlled by PC
Output short-circuit protection: All channels can work more than 60 seconds
Can choose our FYV2000 series or FPA1000 series power amplifier to output
0.1%.
amplitude, offset and duty cycle. It has Linear and Logarithm two sweep types.
Sweep time can be up to 999.99S. Sweep starting point and end point can be
set arbitrarily.
CH2 Trigger, and External Trigger for your options. It can output 1~1048575
pulse trains.
anytime.
width and duty cycle. Max. frequency workable is 100MHz and Min.
frequency workable is 0.01 Hz.
and AC coupling. This design can solve inaccuracy problem of AC coupling.
waveform to this instrument after edit through PC program which is included
in user CD.
program and the communication protocol is open for secondary development.
when the load is short-circuited.
20W~60W signal in DC-3MHz width without any distortion.
FY2300 Series User’s Manual 3
FeelTech
Quick Start
General Inspection
Please follow the items below when you receive a new FY2300 series
Function/Arbitrary Waveform Generator.
1
Inspect the shipping container for damage
Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to instrument resulting from shipment.
2
Inspect the instrument
In case of any damage, or defect, or failure, notify your FeelTech sales
representative.
3
Check the accessories
Please check the accessories according to the Appendix C ( packing lists). If the accessories are incomplete or damaged, please contact your FeelTech sales representative.
4 FY2300 Series User’s Manual
Front Panel Overview
Item
Function
Description
1
Function
Buttons Area
Press this buttons to switch waveforms among Sine,
Square, Triangle and so on.
Press this button to switch between frequency meter and
counter to measure frequency, period, duty cycle and
pulse width of external signal output.
Both DC and AC are workable.
Gate Time can be 1S, 10S or 100S.
Dual channels output and measurement function can
work together at same time.
Can sweep Sine, Square, Arbitrary and so on.
Can sweep frequency, amplitude, offset and phase.
2 sweep types: Linear, Logarithm.
Auxiliary functions and system configuration setting.
Can save 20 sets waveform parameters including
frequency, amplitude, offset, phase and so on.
System Language has English and Chinese for users option.
Buzzer can be turned on/off in this manu.
Set multimachine uplink.
Switch Master-Slave status
The front panel is divided into several function areas for easy operation.
FeelTech
Front Panel
FY2300 Series User’s Manual 5
FeelTech
2
LCD
2.4 inch TFT320×240 color LCD. Operation instruction please
check chapter User Interface.
3
Manu
Buttons
F1~F5 buttons are matched with Manu displayed on the LCD.
Press corresponding button to activate submenu represented.
4
ADJ Knob
Rotate the ADJ Knob to increase or reduce the current value
indicated by the cursor.
Frequency unit can be changed by Press ADJ Knob under
Frequency value setting status.
Press ADJ Knob to Start/Stop sweep under Sweep interface.
5
Arrows
Press Arrow buttons to select figure which you want to edit
when setting values of each parameter.
6
Output
Channels
Control CH1 output. Press it to switch to CH1 parameter
setting interface.
Press it to turn on CH1 output with current
configuration. The indicator will illuminate.
Press it again to turn off CH1 output and the indicator
will extinguish.
Control CH2 output. Press it to switch to CH2 parameter
setting interface.
Press it to turn on CH2 output with current
configuration. The indicator will illuminate.
Press it again to turn off CH2 output and the indicator
will extinguish.
6 FY2300 Series User’s Manual
FeelTech
4. TTL_IO Connector
Right Panel Overview
Right Panel
1. CH2 BNC It is a BNC (female) connector which nominal impedance is 50Ω.The
function of this connector is determined by the work mode of CH2.
2. CH1 BNC It is a BNC (female) connector which nominal impedance is 50Ω.The
function of this connector is determined by the work mode of CH1.
3. EXT.IN Connector It is a BNC (female) connector for inputting signals for measurement.
Impedance is 100KΩ.
Note:
Voltage of signal input CANNOT exceed ±20Vac+dc in case any damage to this instrument.
It is a BNC (female) connector for outputting TTL signal synchronized with CH1 and inputting uplink signal.
1) Under non-uplink status it can output 3.3 Vpp LVTTL signal synchronized with CH1 and output impedance is no higher than 50Ω.
2) When uplink is enabled and work as slave, the connector works as external
signal input interface and input impedance is more than 100 KΩ. Please refer to chapter “Synchronization”.
FY2300 Series User’s Manual 7
FeelTech
1. DC power input connector (External diameter 5.5mm, Inner diameter 2.1mm)
Left Panel Overview
The DC voltage is 5V±0.5V, and electric current is 500 mA. The maximum power input cannot exceed 5W. Instrument also supports DC5V mobile power supply.
Note:
Please use original power adapter and data cable to guarantee normal use.
2. USB Device Interface
This is for communicating with PC.
Use PC Host software to program.
3. Power Switch
Set to “ON” to turn on this instrument or “OFF” to turn it off.
8 FY2300 Series User’s Manual
FeelTech
Power On and Inspection
Connect to Power
Please connect the generator to AC power supply using the Power Adaptor
supplied in the accessories . The specifications of the adaptor: DC voltage is 5V±0.5V, and electric current is 500 mA. The maximum power input cannot exceed 5W.
Power On
Turn on the power switch after the power cord is connected. The generator
will execute self-inspection. The LCD will show welcome interface after the inspection is over. If the generator cannot work normally, please check the Chapter “Troubleshooting” for solution.
Set the System Language
FY2300 series Function/Arbitrary Waveform Generator supports Chinese and
English system languages. You can press SYSCONF to switch the system language.
FY2300 Series User’s Manual 9
FeelTech
The user interface of FY2300 provides four types of display modes: Dual
Channels Parameters (default), Single Channel Extension, Auxiliary Functions
and System Interface.
Item
Description
1
Current channel selected.
Display current channel selected for operation.
2
Current waveform selected.
Display the name of current waveform selected. For example,
CH1=Sine”means current waveform selected of CH1 is
Sine Wave. It can be changed by press WAVE button. Meanwhile, waveform can be changed quickly by rotating ADJ Knob when waveform switch function is activated.
3
Output status of current channel.
User Interface
Dual Channels Parameters (default)
The upper half of LCD displays the channel selected currently and the
parameters can be set. Press CH1 or CH2 to change current channel selected.
10 FY2300 Series User’s Manual
FeelTech
Display On/Off status of current channel. It can be switched
by Press CH1 or CH2.
4
Attenuation
Display attenuation status of current channel. There have 0dB and 20dB attenuation for users option. Press to
enter Single Channel Extension and press ATTE to change the value.
5
Waveform
Display diagram of current waveform(Including Arbitrary
)。
6
Manu Bar
Display current operable options
7
Frequency
Display frequency value of current channel. Press FREQ button to highlight it and use ADJ Knob and Arrows to change the value.
8
Amplitude
Display amplitude value of current channel. Press AMPL button to highlight it and use ADJ Knob and Arrows to change the value.
9
Offset
Display DC Offset value of current channel. Press OFFS button to highlight it and use ADJ Knob and Arrows to change the value.
10
Duty Cycle
Display Duty Cycle value of current channel. Press DUTY button to highlight it and use ADJ Knob and Arrows to change the value.
11
Phase
Display Phase value of current channel. Press button
to enter Single Channel Extension and press PHAS to highlight it and use ADJ Knob and Arrows to change the value.
12
Parameters of the channel unselected.
Display parameters of the channel unselected including frequency, amplitude, offset, phase, duty cycle and output status. These Parameters cannot be changed directly in this interface. If you need to change them, Please switch the channel to be selected.
FY2300 Series User’s Manual 11
FeelTech
Appearance and Dimensions
Front View
Left View
12 FY2300 Series User’s Manual
Right View
FeelTech
FY2300 Series User’s Manual 13
FeelTech
KEY POINT:
CH1 and CH2 can not be selected at the same time. Users can first select CH1 and then select CH2 after configuring the waveform and parameters of CH1. If you need to change the parameters of two channel at same time, please refer to Chapter “Synchronization”.
Front Panel Operations
Waveform Output
FY2300 series can output waveforms (Sine, Square, Triangle/Ramp, Pulse and Noise etc.) from one of the channels separately or from the two channels at the same time. At start-up, the dual channels are configured to output a sine waveform with 10kHz frequency and 10Vpp amplitude by default. Users can configure the instrument to output various waveforms.
Select Output Channel
CH1 and CH2 buttons are used to change current channel selected. At
start-up, CH1 is displayed on the top with yellow color and CH2 is displayed on the bottom with blue color. Press CH1 or CH2 to select channel needed. When selecting CH2 as output channel, CH2 parameters displays on the top for configuration.
14 FY2300 Series User’s Manual
Select Waveform
Sine
Square
Triangle/Ramp
Rise Sawtooth
Fall Sawtooth
Lorenz Pulse
Multitone
Noise
Electrocardiogram (ECG)
Trapezoidal Pulse
Sinc Pulse
Narrow Pulse
Gauss White Noise
Step Triangle
Positive Step
Inverse Step
Positive Exponent
Inverse Exponent
Positive Falling Exponent
Inverse Falling Exponent
Positive Logarithm
Inverse Logarithm
Positive Falling Logarithm
Inverse Falling Logarithm
Linear FM
AM
FM
Positive Half Wave
Negative Half Wave
Positive Half Wave
Rectification
Negative Half Wave
Rectification
User-defined waveform
Waveforms
Sine
Square
Triangle
Sawtooth
Arbitrary
Function Name
SINE
SQUR
TRGL
Ramp
Arb
Parameters
Frequency
√√√√√
Amplitude
√√√√√
Offset
√√√√√
Phase
√√√√√
Duty Cycle
FY2300 can output Function/Arbitrary Waveform including:
FeelTech
Press WAVE to change waveform selected. Or rotate ADJ Knob under waveform switching status to change waveform. The waveform diagram displays on the screen. At start-up Sine is selected by default. (Users can also configure start-up waveform. Please check Chapter “Save and Load”.
Note: Arbitrary waveforms can be edited and downloaded from PC software provided by FeelTech.
FY2300 Series User’s Manual 15
FeelTech
Set Frequency
Frequency is one of the most important parameters of waveforms. For different instrument models and waveforms, the setting ranges of frequency are different. For detailed information, please refer to Frequency in “Specifications”. The default frequency is 10kHz.
Press FREQ button to highlight value of Frequency. Then use Arrow buttons and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
Under setting frequency status, press ADJ Knob to change frequency units among MHz, KHz, Hz, mHz, μHz.
16 FY2300 Series User’s Manual
FeelTech
Set Amplitude
The amplitude setting range is limited by the “Attenuation” and “Frequency” settings. Please refer to “Output Characteristics” in “Specifications”. The default value is 10Vpp.
Press AMPL button to highlight amplitude value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
When Attenuation is 20dB, Amplitude output will be reduced by 10 times.
FY2300 Series User’s Manual 17
FeelTech
Key Points
1. What’s the difference of amplitude in Vpp and the corresponding value in Vrms?
Answer:
Vpp is the unit for signal peak-peak value and Vrms is the unit for signal effective value.
The default unit is Vpp.
Note
For different waveforms, the relation between Vpp and Vrms is different. The relation of the two units is as shown in the figure below (take sine waveform as an example).
According to the figure above, the conversion relation between Vpp and Vrms fulfills the following equation:
Vpp = 22Vrms
For example, if the current amplitude is 5Vpp, For sine waveform, the converted value is 1.768Vrms.
18 FY2300 Series User’s Manual
FeelTech
Set Offset
The DC offset setting range is limited by the “Attenuation”. Please refer to the “Output Characteristics” in “Specifications”. The default value is 0VDC.
The DC offset voltage displayed on the screen is the default value or the offset previously set. When the attenuation value is changed, the instrument will set the value according to the attenuation value automatically.
Press OFFS button to highlight offset value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
FY2300 Series User’s Manual 19
FeelTech
The setting range of duty cycle is 0.1%-99.9%
Press ADJ Knob under duty cycle setting status will initial the value to 50%.
Set Duty Cycle (Square)
Duty cycle is defined as the percentage that the high level takes up in the whole period (as shown in the figure below). This parameter is only available when square is selected.
The setting range of duty cycle is limited by the “FREQ” setting. Please refer to “Waveform Characteristics” in “Specifications”. The default value is 50%.
Press DUTY button to highlight duty cycle value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
20 FY2300 Series User’s Manual
FeelTech
Set Phase
The setting range of phase is from 0° to 359° and the default is 0° The start phase displayed on the screen is the default value or the phase
previously set.
Press
button to highlight phase value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
button to enter Single Channel Extension. Then press PHAS
FY2300 Series User’s Manual 21
FeelTech
1) Generator is in parameter setting status and current channel selected is
2) Generator is in other working status or current channel selected is not
3) Generator is in parameter setting status and current channel selected is
4) Generator is in other working status or current channel selected is not
Enable Output
After configuring the parameters of the waveform selected, waveform output could be enabled. At start-up output of CH1 and CH2 are both turned as default. At this time indicator lights of dual channels illuminate.
For CH1 there are two status:
CH1, then press CH1 to switch between output ON/OFF.
CH1, then press CH1 to make CH1 as channel selected and press CH1 again to switch between output ON/OFF.
For CH2 there are two status:
CH2, then press CH2 to switch between output ON/OFF.
CH2, then press CH2 to make CH2 as channel selected and press CH2 again to switch between output ON/OFF.
22 FY2300 Series User’s Manual
FeelTech
AMPL:02.50V
OFFS:01.60V
PHAS:090°
Example
This section mainly introduces how to output a sine waveform (Frequency: 20kHz, Amplitude:2.5Vpp, DC Offset: 1.6VDC, Start Phase: 90°) from the [CH1] channel.
1. Select output channel
Press CH1 to select CH1. Now all characters and border of the channel is
displayed in yellow.
2. Select the Sine
Press WAVE button to select Sine. Then the diagram of Sine displays on the
screen.
3. Set the frequency
Press FREQ button to highlight the frequency value. Press Arrow buttons to
move the cursor to the position “2” below. Then rotate the ADJ Knob to get “2”.
Output Sine Waveform
FREQ:00’020.000’000’000kHz
4. Set the Amplitude
Press AMPL to highlight the amplitude value. Press Arrow buttons to move
the cursor and rotate the ADJ Knob to get the figures below.
5. Set Offset
Press OFFS to highlight the offset value. Press Arrow buttons to move the
cursor and rotate the ADJ Knob to get the figures below.
6. Set Phase
Press button to page down and press PHAS button to highlight phase value. Then Press Arrow buttons to move the cursor and rotate the ADJ Knob to get the figures below.
7. Enable the output
Press CH1 button to turn CH1 output on. The [CH1] connector outputs the configured waveform.
8. Observe the output waveform
Connect the [CH1] connector to the oscilloscope with BNC cable. The waveform is as shown below.
FY2300 Series User’s Manual 23
FeelTech
24 FY2300 Series User’s Manual
FeelTech
NORMAL: The Burst function is disabled
CH2 Trigger: CH1 will generate a burst when CH2 generates a pulse.
Ext. Trigger: CH1 will generate a burst when EXT.IN connector was inputted a
MANU Trigger: User can trigger a burst by pressing ADJ Knob (OK button).
Generate a Burst Waveform
This instrument can output a burst (waveform with specified number of cycles) using standard waveforms such as sine, square, Triangle/ramp, and noise, or arbitrary waveforms. The instrument supports control of burst output by internal CH2, manual and external trigger source.
Enable Burst Function
Press button in CH1 parameter setting status. Then press “TRIG” button to enter burst function. Then press TRIG button to select trigger sources from “ CH2”, “Ext.” and “MANU”. Then the generator will output burst waveform according to current configuration.
When the burst function is enabled, press No. button to set the cycles of burst. Use arrow buttons and ADJ Knob to set the numbers from 1 to 1048575.
pulse.
FY2300 Series User’s Manual 25
FeelTech
Key Point
Amplitude of signal input should be bigger than 1.5V. Maximum safe
voltage input is 20V.
Frequency Meter/Counter
FY2300 provides a counter which can measure various parameters of external input signal such as frequency, period, duty cycle, positive pulse width and negative pulse width. Dual channels output can work together with counter.
Enable the Counter
Press MEAS button of the front panel to enable the counter and measurement Manu. External signal for measurement can be inputted by EXT.IN connector and the result will be displayed on the screen in real time. The lowest frequency workable is 0.01 Hz.(GATE TIME:100S
Press COUN button to enter external pulse counter function. At this time COUN button is turned into FREQ button. Repeat pressing this button to switch between FREQ and COUN.
)。
Frequency Meter/Counter Interface
When the Frequency Meter/Counter is turned on, press STOP button to pause and press ZERO button to reset.
26 FY2300 Series User’s Manual
FeelTech
Gate Time
Frequency Resolution
1S
1Hz
10S
0.1Hz
100S
0.01Hz
Set the Counter
Gate Time
Press GATE button to select gate time. The default is “1S”. It’s better to use “10S” as gate time for low frequency signal.
Coupling
Set the coupling mode of the input signal to “AC” or “DC” and the default is “AC”.
FY2300 Series User’s Manual 27
FeelTech
In Frequency Sweep Mode, the generator will output signal variably from
In Amplitude Sweep Mode, the generator will output signal variably from
In Offset Sweep Mode, the generator will output signal variably from start
In Duty Cycle Sweep Mode, the generator will output signal variably from
Sweep
Press SWEEP button of front panel to enable sweep function. FY2300 can output sweep from CH1. In sweep mode, the generator outputs signal variably from the start frequency to stop frequency within the specified sweep time. It can generate sweep output for Sine, Square, Triangle/Ramp and arbitrary waveform.
Sweep Object
FY2300 Can output sweep from CH1. The sweep objects include frequency, amplitude, offset, duty cycle. It can be selected by pressing OBJE button.
start frequency to end frequency within the specified sweep time.
start amplitude to end amplitude within the specified sweep time.
offset to end offset within the specified sweep time.
start duty cycle to end duty cycle within the specified sweep time.
28 FY2300 Series User’s Manual
FeelTech
Frequency Sweep: Press STAR button to highlight start frequency
Amplitude Sweep: Press STAR button to highlight start amplitude parameter.
Offset Sweep: Press STAR button to highlight start offset parameter. Press
Duty Cycle Sweep: Press STAR button to highlight start duty cycle
Sweep Start Position
When Sweep function is enabled. Sweep start position need to be set according to sweep objects.
parameter. Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
START
Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
START
the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
START
parameter. Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
START
00’010.000’000’000kHz
10.00V
00.00V
50.0%
FY2300 Series User’s Manual 29
FeelTech
Frequency Sweep: Press END button to highlight end frequency parameter.
Amplitude Sweep: Press END button to highlight end amplitude parameter.
Offset Sweep: Press END button to highlight end offset parameter. Press
Duty Cycle Sweep: Press END button to highlight end duty cycle parameter.
Sweep End Position
When Sweep function is enabled. Sweep end position need to be set according to sweep objects.
Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
END:00’020.000’000’000kHz
Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
END:20.00V
the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
END:10.00V
Press the Arrow buttons and rotate the ADJ Knob to set the specified value. For example:
END:80.0%
30 FY2300 Series User’s Manual
FeelTech
Sweep Time
When Sweep function is enabled, press TIME button to highlight time parameter. Press the Arrow buttons and rotate the ADJ Knob to set the specified value. The default is “1S”. The work range is 10mS~999.99S. For Example:
TIME:999.99S
FY2300 Series User’s Manual 31
FeelTech
Sweep Type
FY2300 provides Linear, Logarithm sweep types. The default is Linear sweep. The sweep type can be switched by pressing “MODE” button.
Linear Sweep
In linear sweep type, the signal parameter varies linearly. For example, in the frequency sweep the output frequency of the instrument varies linearly in the way of “Changing several Hertz per second”. The variation is controlled by “Start Frequency”, “End Frequency” and “Sweep Time”.
The step value of linear sweep object is computed by the generator, the
formula is as follows:
Step value=(End value
Logarithm Sweep
Start value)/(Sweep time*100
In linear sweep type, the signal parameter varies logarithmically.
For example, in the frequency sweep the output frequency changes in the way of
“octave per second” or “decade per second”. The variation is controlled by “Start
Frequency”, “End Frequency” and “Sweep Time”.
When Logarithm Sweep is enabled, users can set the following parameters: Start Frequency (Fstart), Stop Frequency (Fend) and Sweep Time (Tsweep).
The function prototype of Logarithm Sweep:
F
current
F expressed as shown below by the above-mentioned parameters:
is the instantaneous frequency of the current output. P and T could be
current
lg(F
P=10
stop/Fend
T=t+lg(F
Wherein, t is the time from the start of the sweep and its range is from 0 to T
sweep.
=P
start
T
)/T
sweep
)/lg(P)
32 FY2300 Series User’s Manual
FeelTech
Start Frequency < End Frequency: the generator sweeps from low
Start Frequency > End Frequency: the generator sweeps from high
Start Frequency = Stop Frequency: the generator outputs with a fixed
Enable Sweep Function
Press SWEEP button of front panel to enable sweep function. Then press ADJ Knob to start sweep process. Press ADJ Knob again to stop sweep.
Start value and End value
Start value and stop value are the upper and lower limits of sweep for specified parameter. sweep. The generator always sweeps from the start value to the end value and then returns back to the start value and continues indefinitely.
For example, in Frequency Sweep function:
frequency to high frequency.
frequency to low frequency.
frequency.
When Sweep function is enabled, press STAR button to highlight start value. Use arrow buttons and ADJ Knob to set the specified value. Different frequency sweep corresponds to different start frequency and end frequency range.
Sine
Square
Ramp
Arbitrary:10mHz to 6MHz
The generator will restart sweep (according to the current new configuration) from the specified “start frequency” after start or end frequency is changed.
10mHz to 25MHz
10mHz to 6MHz
10mHz to 5MHz
FY2300 Series User’s Manual 33
FeelTech
System Configuration and Auxiliary Functions
Press SYS button of front panel to enter System interface.
SAVE: To save current parameters of waveform to save positions (20 sets).
LOAD: To load parameters to current working status from save positions.
SYNC: To synchronize CH2 parameter with CH1. Each parameter can be
selected separately for synchronization including waveform, frequency, amplitude, offset and duty cycle.
CONF: To set system language, turn on/off Buzzer and Uplink mode.
34 FY2300 Series User’s Manual
FeelTech
FY2300 provides 20 positions for saving.
The generator will load default parameters from Position 1
Save and Load
Press SAVE button in System interface to save parameters of current waveform to specified position. Press “Load” button to load parameters of waveforms previously set to current system status.
Select S xx on the right to save current parameters to corresponding position.
Select L xx on the right to load parameters from corresponding position to current system status.
automatically after start-up.
FY2300 Series User’s Manual 35
FeelTech
nchronization
Sy
Press SYNC button in system interface to enter synchronization setting interface. Press corresponding buttons on the right to highlight or cancel selecting status to set synchronization status of CH2.
When the synchronization of corresponding parameters are activated, the corresponding parameters of CH2 will vary according to variation of CH1 automatically. The parameters workable for synchronization include waveform, frequency, amplitude, offset, and duty cycle, which can be set separately.
When WAVE is highlighted, the waveform of CH2 will vary according to variation of CH1.
When FREQ is highlighted, the frequency of CH2 will vary according to variation of CH1.
When AMPL is highlighted, the amplitude of CH2 will vary according to variation of CH1.
When OFFS is highlighted, the offset of CH2 will vary according to variation of CH1.
When DUTY is highlighted, the duty cycle of CH2 will vary according to variation of CH1.
36 FY2300 Series User’s Manual
FeelTech
Press 中文 button to select Chinese as system language.
Press Eng button to select English as system language.
Press BUZZ button to turn on/off buzzer. On is the default.
Press M/S button to set uplink mode: Master/Slave. Master is the
Press UPLI button to turn on/off uplink function. Off is the default.
Configuration
Press SYS button to enter system interface. Then press “CONF” button to enter system configuration interface. Press corresponding buttons to select system work mode.
default.
FY2300 Series User’s Manual 37
FeelTech
Select on FY2300 as master machine. Press SYS -> CONF ->M/S, to set the
Set all other machines to be slave machines. Press SYS -> CONF ->M/S, to
Connect all FY2300 in parallel by TTL_IO connecter.
The uplink machines cannot exceed 8 because the driving ability.
Uplink
FY2300 supports multi-machine uplink, which can provide users more channels for output. In uplink network, only one master machine can exist. Others must be set as slave machine. The setting method is as follows:
UPLINK MODE to be “Master”. Press UPLI, to set the UPLINK to be “ON”.
set the UPLINK MODE to be “Slave”. Press UPLI, to set the UPLINK to be “ON”. Repeat this step to set all slave machines.
When the setting above has been finished, all machines in network will work synchronously according to the start phase of master machine. When outputting signal with same frequency, multi channels output can be executed with phase adjustable.
38 FY2300 Series User’s Manual
FeelTech
Failure Phenomena
Solutions
The screen of the generator is still dark (no display) after switch on.
1) Check whether the power is correctly connected.
2) Check whether the power switch has been pulled in place.
3) Restart the instrument after finishing the above inspections.
4) Use USB-B cable to input power.
5) If it still does not work correctly, please contact
FeelTech.
. The screen of the generator is still dark (no display) after switch on, but the channel indicator lights illuminate.
This is because the power supply is not enough.
1). Please use original power adapter. If you need to connect to PC, please select USB port with enough current.
2). Please use original data cable because the original one has communicating function when supplying power, which others may don’t have.
3). Please do not repeat switching the power switch too soon. The instrument has power protection. Please wait for 2S at least to switch on after it is switched off.
CH2 is locked.
1) Check whether the generator is worked in synchronization mode. Press SYS button to enter system interface, then press SYNC button to enter synchronization setting interface and cancel all parameters selected.
2) If the problem is still, please restart the generator.
The settings are correct but theres no waveform being generated:
1) Check whether the BNC cable is connected tightly with CH1 or CH2 connector.
2) Check whether the BNC cable has internal damage.
3) Check whether the BNC cable is connected tightly with the test instrument.
4) Check whether the indicators of CH1 or CH2 is turned on. If not press corresponding button to turn it on.
5) If the problem is still, please contact FeelTech.
Troubleshooting
This chapter lists the commonly encountered failures of FY2300 and their solutions. When you encounter these problems, please solve them following the corresponding steps below. If the problem remains still, please contact FeelTech and provide the device information (Press SYS to get it).
FY2300 Series User’s Manual 39
FeelTech
The generator has passed self-inspection.
The generator has been working continuously for at least 30 minutes
Frequency
FY2300
-6MHz
FY2300
-12MHz
FY2300
-15MHz
FY2300
-20MHz
FY2300
-25MHz
Sine
0~6MHz
0~12MHz
0~15MHz
0~20MHz
0~25MHz
Square
0~6MHz
0~6MHz
0~6MHz
0~6MHz
0~6MHz
Ramp/Triangle
0~6MHz
0~6MHz
0~6MHz
0~6MHz
0~6MHz
Pulse
0~6MHz
0~6MHz
0~6MHz
0~6MHz
0~6MHz
TTL
0~6MHz
0~6MHz
0~6MHz
0~6MHz
0~6MHz
Others
0~6MHz
0~6MHz
0~6MHz
0~6MHz
0~6MHz
Resolution
1μHz (0.000001Hz)
Accuracy
± 5×10
-6
Stability
±1×10-6/ 3 Hours
Impedance
50Ω±10%Typical
Phase Range
0~359°
Phase Resolution
Waveform Characteristics
Waveforms
Sine, Square, Triangle(Ramp), Arbitrary, Rise Sawtooth, Fall
Sawtooth, Lorenz Pulse, Multitone, Noise, Cardiogram, Rapezoidal
Pulse, Sinc Pulse, Narrow Pulse, Gauss White Noise, AM, FM, Step.
Waveform Length
2048Points
Sampling Rate
200MSa/s
Vertical Resolution
12 Bits
Sine Harmonic
Suppression
≥45dBc(<1MHz);≥40dBc(1MHz~20MHz);
Total Harmonic
Distortion
<0.8% (20Hz~20kHz,0dBm)
Square
Rise/Fall Time
≤20ns
Overshoot
≤7.5%
Duty Cycle
0.1%~99.9%
Technical Specification
Unless specified, all specifications can be guaranteed if the following two conditions are met.
under the specified temperature (18℃~28℃).
All the specifications are guaranteed unless those marked with “typical”
40 FY2300 Series User’s Manual
FeelTech
Sawtooth
Linearity
≥98% (0.01Hz~10kHz)
Output characteristics
Amplitude (50Ω)
10mVpp~20Vpp
Amplitude Resolution
1mV (Attenuate 20dB)
Amplitude Stability
±0.5%/ 5 Hours
Amplitude flatness
±5%(<10MHz)±10%(>10MHz);
Waveform Output
Impedance
50Ω±10%Typical
Protection
All channels can work more than 60 seconds when the load is
short-circuited.
Dc Offset
Offset Range
±10V
Offset Resolution
0.01V (0.001V With Attenuation)
TTL Output
Electrical Level
Amplitude
>3Vpp Fan-out
>20 TTL Load
Rise/Fall Time
≤20ns
CMOS Output
Low Electric Level
<0.3V
High Electric Level
1V~10V
Rise/Fall Time
≤20ns
External Measurement
Frequency Meter Range
0.01Hz~100MHz
Sensitivity
Gate Time 3 grades adjustable
Counter
Range
0-4294967295
Coupling
DC , AC
Working Mode
Manual
Pulse Width
measurement
Resolution 5 nS. Max. 10S Voltage Input Range
0.7Vpp~20Vpp
Period Measurement
Resolution 5nsMax. Limit 10s
Sweep
Only CH1 available Sweep Type
Linear or :Logarithm
FY2300 Series User’s Manual 41
FeelTech
Sweep Objects
Frequency, Amplitude, Offset, Duty Cycle
Sweep Time
0.01S~999.99S/Step
Sweep Range
Starting position and Finishing position can be set arbitrarily.
General Specifications
Display
Mode
2.4 inch TFT Color Lcd.
Save & Load Amount
20
Position
01 to20 (01 for default value)
Interface
Type
USB to Serial interface.
Communicati
ng Speed
9600bps Protocol
Command line mode, protocol complete open.
Power
Voltage
Range
DC5V±0.5V Buzzer
Can be turned on/off by setting.
Environment
Temp.0~40Humidity:﹤80%
Dimension
140mmLengthX95mmWidthX54.2mmHeight
Weight
Net Weight: 450gGross Weight: 750g
42 FY2300 Series User’s Manual
FeelTech
Description
Quantity
Model
FY2300-6M
6MHz, Dual-channel
1
FY2300-12M12MHz, Dual-channel
FY2300-15M15MHz, Dual-channel
FY2300-20M20MHz, Dual-channel
FY2300-25M(25MHz, Dual-channel
Standard Accessories
5V 1A Power Adapter
1
USB-B Data/Power Cable
1
BNC-Clip Cable
2
Resource CD (including the User’s Manual)
1
Warranty Card
1
Options
BNC-BNC cable
FYA2000/FPA1000 Series Amplifier
Appendix
Appendix ASafety Notes
1. Before using this instrument, please check if the power supply is normal, to
ensure the normal use and personal safety.
2. This instrument must be used in the technical index range.
3. Please do not change the instrument circuit arbitrarily, so as to avoid damaging
equipment or endangering the safety.
Appendix BWarning and personal injury
Do not apply the product in the safety protection device or emergency stop device, or any other applications that the product failure could result in personal injury, unless there is special purpose or use authorization. Before the installation and use, each parameter of the technical indexes in this manual should be referred to. If this suggestion is not obeyed, death or serious personal injury could be caused. In this condition the company will not be responsible for any compensation of personal injury or death, and all the company managers and employees and auxiliary agents, distributors, other personnel concerned will be released from any claim (including all the costs, expenses, attorney fees etc.) that may result in.
Appendix CAccessories and Options
Note: Options can be ordered from local FeelTech distributors.
FY2300 Series User’s Manual 43
FeelTech
Appendix D:Warranty
FeelTech warrants that its products mainframe and accessories will be free
from defects in materials and workmanship within the warranty period. If a product is proven to be defective within the respective period, FeelTech guarantees the free replacement or repair of products which are approved defective. This product enjoy 1 year warranty since its delivery. Damages caused by misuse, vandalism, improper maintenance or force majeure are not covered by the warranty. Any disassembly or amendment without permission will be deemed giving up warranty rights consciously.
44 FY2300 Series User’s Manual
Loading...