Warranty – Seller warrants all goods for ve years on parts and 2-1/2 years on labor, under the following conditions and exceptions: Seller warrants that all goods of Seller's manufacture will conform to any descriptions thereof for specications which are expressly made a part of this sales contract and at the time of sale by Seller such goods shall be commercially free from defects in material or workmanship. Seller reserves the right at the Seller’s discretion to “Repair and Return” or “Replace” any item deemed defective during the warranty period. This warranty does not cover travel expenses, the cost of specialized equipment for gaining access to the product, or labor charges for removal and reinstallation of the product. This warranty shall be ineffective and shall not apply to goods that have been subjected to misuse, neglect, accident, damage, improper maintenance, or to goods altered or repaired by anyone other than Seller or its authorized representative, or if ve years have elapsed from the date of shipment of the goods by Seller with the following exceptions: lamps and strobe tubes are not covered under this warranty. Outdoor warning sirens and controllers manufactured by Federal Warning Systems are warranteed for two years on parts and one year on labor. No agent, employee, representative or distributor of Seller has any authority to bind the Seller to any representation, afrmation, or warranty concerning the goods and any such representation, afrmation or warranty shall not be deemed to have become a part of the basics of the sales contract and shall be unenforceable. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR MERCHANTABILITY, FITNESS FOR PURPOSE AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. These warranties shall not apply unless Seller shall be given reasonable opportunity to investigate all claims for allegedly defective goods. Upon Seller's instruction a sample only of allegedly defective goods shall be returned to Seller for its inspection and approval. The basis of all claims for alleged defects in the goods not discoverable upon reasonable inspection thereof pursuant to paragraph 8 hereof must be fully explained in writing and received by Seller within thirty days after Buyer learns of the defect or such claim shall be deemed waived.
Industrial Systems
2645 Federal Signal Drive • University Park, IL 60484-3167 Tel: 708-534-4756 • 877-289-3246 • Fax: 708-534-4852 Email: elp@federalsignal.com • www.federalsignal-indust.com
Contents
Safety Messages to Installers and Users ...................................5
Certication ...................................................................................6
Unpacking the Amplied Speaker ..............................................7
Creating Combination Fixtures in the Field ...............................7
Mounting the Amplied Speaker .................................................8
Mounting the Trunnion-Mount Amplied speaker ............................ 8
Mounting the Surface-Mount Ex d Amplied Speaker ................... 10
Mounting the Ex de Surface-Mount Amplied Speaker ...................11
Safety Messages for Wiring .......................................................13
Connecting to the Terminal Block ............................................14
Preparing to Wire the Ex d Flameproof Models .......................14
Wiring the Ex d Models ................................................................... 15
Adjusting the Sound Pressure and Audio Input (Ex d) .................... 17
Preparing to Wire the Ex de Increased Safety Models ............19
Wiring the Ex de Models ................................................................. 20
Adjusting the Sound Pressure and Audio Input (Ex de) .................. 22
Safety Messages to Maintenance Personnel ...........................23
Maintaining the Amplied Speaker ...........................................24
Cleaning the Enclosure .................................................................... 24
Lubricating the Threaded Joints ....................................................... 24
Ordering Replacement Parts and Accessories .......................24
Getting Repair Service or Technical Assistance .....................25
Returning the Product for Credit ..............................................27
Model G-SPA Global Series Amplied Speaker
3
Contents
Tables
Table 1 Replacement part ..................................................................... 25
Table 2 Accessories .............................................................................. 25
Table 3 Choosing cable-entry devices for Equipment
in Potentially Explosive Atmospheres .....................................................26
Figures
Figure 1 Beacon and amplied speaker combination xture .................. 8
Figure 2 Bracket dimensions .................................................................. 9
Figure 3 Front view of trunnion-mount amplied speaker....................... 9
Figure 4 Side view of trunnion mount amplied speaker ...................... 10
Figure 5 Front view of Ex d amplied speaker...................................... 10
Figure 7 Front view of Ex de surface mount ......................................... 11
Figure 8 Side view of Ex de surface mount .......................................... 12
Figure 9 Disengaging a terminal block spring clamp ............................ 14
Figure 10 Ex d in/out PCB connections ................................................ 15
Figure 11 Location of VR1 potentiometer (sound pressure) ................. 17
Figure 12 Location of jumper JP3 (audio input) .................................. 18
Figure 13 Connections for DC or AC Ex de amplied speaker ............. 20
© 2015 Federal Signal Corporation. All rights reserved.
4
Model G-SPA Global Series Amplied Speaker
Installation and Maintenance Instructions
Safety Messages to Installers and Users
It is important to follow all instructions shipped with this product. This amplied speaker is to be installed by a trained electrician who is thoroughly familiar with and will follow all applicable national and local codes in the country of use.
This amplied speaker should be considered a part of the warning system and not the entire warning system.
The selection of the mounting location for the amplied speaker, its controls and the routing of the wiring are to be accomplished under the direction of the facilities engineer and the safety engineer. In addition, listed below are some other important safety instructions and precautions you should follow:
Read and understand all instructions before installing or operating this equipment.
To avoid electrical shock hazards, do not connect wires when power is applied. Failure to observe this warning may lead to serious injury or death.
Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or other alterations are made in units specically designed for use in these locations.
Do not connect this amplied speaker to the system when power is on.
All effective warning speakers produce loud sounds, which may cause, in certain situations, permanent hearing loss. Take appropriate precautions such as hearing protection. The device should be installed far enough away from potential listeners to limit their exposure while still maintaining its effectiveness.
After installation, ensure that all threaded joints are properly tightened.
Model G-SPA Global Series Amplied Speaker
5
Installation and Maintenance Instructions
• After installation, test the amplied speaker system to ensure that it is operating properly
Keep the unit tightly closed when in operation.
After testing is complete, provide a copy of this instruction sheet to all personnel.
Brass inserts have the potential to store charge when they are not plugged. Consideration should be taken to prevent these from becoming a sparking hazard.
Establish a procedure to routinely check the amplied speaker system for proper activation and operation.
Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death.
Certication
Certicate Nos.: ATEX Cert No.: Baseefa15ATEX0155X IECEx Cert No.: IECEx BAS 15.0104X
ATEX coding: II 2 G D
Protection: Ex db IIB T5 Gb or Ex db e IIB T5 Gb Ex tb IIIC T100°C Db IP66 (Tamb = -50°C to + 49°C) Ex db IIC T4 Gb or Ex db e IIC T4 Gb Ex tb IIIC T135°C Db IP66 (Tamb = -50°C to + 60°C)
Standards: EN60079-0: 2012 +A11:2013, EN60079-1: 2014, EN60079-7: 2007, EN60079-31: 2014, IEC60079-0: 6th Ed.,
IEC 60079-1: 7th Ed., IEC 60079-7: 4th Ed., IEC 60079-31:2nd Ed
Specic Conditions of Use:
1. The Modular Audible Device enclosure incorporates a sinter and
the volume is greater than 100 cm3, therefore use of the Modular Audible Device in carbon disulphide gas atmospheres is not permitted.
2. The Modular Audible Device has external non-metallic surfaces
which may provide electrostatic charging hazard. See the manufacturer's instructions for further information.
6
Model G-SPA Global Series Amplied Speaker
Installation and Maintenance Instructions
3. The Modular Audible Device has metallic components in the non-
metallic walls of the enclosure which can store electrical charge
and therefore may provide a potential electrostatic discharge. The metallic brass inserts have a capacitance of 24 pF. See the manufacturer's instructions for further information.
Unpacking the Amplied Speaker
After unpacking the amplied speaker, examine it for damage that may have occurred in transit. If it has been damaged, do not attempt to install or operate it. File a claim immediately with the carrier, stating the extent of the damage. Carefully check all envelopes, shipping labels, and tags before removing or discarding them. Disposal of all shipping
materials must be carried out in accordance with national and local
codes and standards. If any parts are missing, please call Federal Signal Customer Support at +1 708-534-4756 or +1 877-289-3246.
Creating Combination Fixtures in the Field
The Federal Signal Global Series Ex de products can be connected together in the eld using interchangeable E-box end caps and a proprietary coupling system.
The proprietary coupling system allows for simple and cost effective, wiring from product to product often eliminating the need for expensive Ex wiring practices and Ex rated glands. The E-box is available only when factory installed on an Ex d unit or when used as a E-box spacer adjoining an existing E-box. Please refer to the accessories listed on page 25 for available options. When creating certain xture combinations, it is necessary to replace E-box end caps before mounting the product. If you are creating combination xtures, refer to instruction manual 25500259 for specic instructions and details.
A note about combination xtures: If the product is Ex db marked only, it is for use in gas atmospheres. If the product is Ex db e marked, it uses the increased-safety terminal enclosures and is only for gas atmospheres. If the product is Ex tb marked, it is for installation in dust atmospheres.
Model G-SPA Global Series Amplied Speaker
7
Installation and Maintenance Instructions
Figure 1 Beacon and amplied speaker combination xture
Mounting the Amplied Speaker
ATTACH THE AMPLIFIED SPEAKER SECURELY: To prevent injury, this apparatus must be securely attached to the mounting surface in accordance with the installation instructions. Use installer­supplied fasteners suitable for the mounting surface.
The mounting method and the installer-supplied mounting hardware depend on which of the three G-SPA models you are installing:
Mounting the Trunnion-Mount Amplied speaker
For the amplied speaker dimensions, see Figures 3 on page 9 and 4 on page 10. Mount the trunnion bracket to a at surface using the two 7.0 mm mounting holes (Figure 2). Use installer-supplied fasteners suitable for the surface to which the device will be mounted.
8
Model G-SPA Global Series Amplied Speaker
Installation and Maintenance Instructions
60.0 mm
2X M6 SCREW HOLE
189.2 mm
To adjust the vertical angle of the amplied speaker, loosen the fasteners on the mounting bracket to disengage the ratchet. Vertically aim the amplied speaker, and tighten the fasteners.
Figure 2 Bracket dimensions
(2.36 in)
31.8 mm (1.25 in)
Figure 3 Front view of trunnion-mount amplied speaker
(7.45 in)
215.2 mm (8.47 in)
Model G-SPA Global Series Amplied Speaker