Federal Signal Corporation Global G-SPA-D Series, Global G-SPA-E Series, Global G-SPA-T Series, Global G-SPA Series, Global Series Installation And Maintenance Instructions Manual
Federal Signal Corporation Installation And Maintenance Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Global Series
Model G-SPA Amplied Speaker
For Use in Hazardous Locations
Installation and
Maintenance Instructions
To view this manual in Portuguese, go to www.federalsignal-indust.com.
To view this manual in Mandarin, go to www.federalsignal-indust.com.
To view this manual in Russian, go to www.federalsignal-indust.com.
25500188
Rev. A0 0815
Printed in U.S.A.
Warranty – Seller warrants all goods for ve years on parts and 2-1/2 years
on labor, under the following conditions and exceptions: Seller warrants that
all goods of Seller's manufacture will conform to any descriptions thereof
for specications which are expressly made a part of this sales contract and
at the time of sale by Seller such goods shall be commercially free from
defects in material or workmanship. Seller reserves the right at the Seller’s
discretion to “Repair and Return” or “Replace” any item deemed defective
during the warranty period. This warranty does not cover travel expenses,
the cost of specialized equipment for gaining access to the product, or labor
charges for removal and reinstallation of the product. This warranty shall be
ineffective and shall not apply to goods that have been subjected to misuse,
neglect, accident, damage, improper maintenance, or to goods altered or
repaired by anyone other than Seller or its authorized representative, or if
ve years have elapsed from the date of shipment of the goods by Seller with
the following exceptions: lamps and strobe tubes are not covered under this
warranty. Outdoor warning sirens and controllers manufactured by Federal
Warning Systems are warranteed for two years on parts and one year on labor.
No agent, employee, representative or distributor of Seller has any authority
to bind the Seller to any representation, afrmation, or warranty concerning
the goods and any such representation, afrmation or warranty shall not be
deemed to have become a part of the basics of the sales contract and shall
be unenforceable. THE FOREGOING WARRANTIES ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER WARRANTIES OR MERCHANTABILITY,
FITNESS FOR PURPOSE AND OF ANY OTHER TYPE, WHETHER
EXPRESS OR IMPLIED. These warranties shall not apply unless Seller
shall be given reasonable opportunity to investigate all claims for allegedly
defective goods. Upon Seller's instruction a sample only of allegedly defective
goods shall be returned to Seller for its inspection and approval. The basis of
all claims for alleged defects in the goods not discoverable upon reasonable
inspection thereof pursuant to paragraph 8 hereof must be fully explained
in writing and received by Seller within thirty days after Buyer learns of the
defect or such claim shall be deemed waived.
Industrial Systems
2645 Federal Signal Drive • University Park, IL 60484-3167
Tel: 708-534-4756 • 877-289-3246 • Fax: 708-534-4852
Email: elp@federalsignal.com • www.federalsignal-indust.com
Contents
Safety Messages to Installers and Users ...................................5
It is important to follow all instructions shipped with this product.
This amplied speaker is to be installed by a trained electrician who
is thoroughly familiar with and will follow all applicable national and
local codes in the country of use.
This amplied speaker should be considered a part of the warning
system and not the entire warning system.
The selection of the mounting location for the amplied speaker, its
controls and the routing of the wiring are to be accomplished under
the direction of the facilities engineer and the safety engineer. In
addition, listed below are some other important safety instructions and
precautions you should follow:
• Read and understand all instructions before installing or operating
this equipment.
• To avoid electrical shock hazards, do not connect wires when
power is applied. Failure to observe this warning may lead to
serious injury or death.
• Never alter the unit in any manner. Safety in hazardous locations
may be endangered if additional openings or other alterations are
made in units specically designed for use in these locations.
• Do not connect this amplied speaker to the system when power
is on.
• All effective warning speakers produce loud sounds, which
may cause, in certain situations, permanent hearing loss. Take
appropriate precautions such as hearing protection. The device
should be installed far enough away from potential listeners to
limit their exposure while still maintaining its effectiveness.
• After installation, ensure that all threaded joints are properly
tightened.
Model G-SPA Global Series Amplied Speaker
5
Installation and Maintenance Instructions
• After installation, test the amplied speaker system to ensure that
it is operating properly
• Keep the unit tightly closed when in operation.
• After testing is complete, provide a copy of this instruction sheet
to all personnel.
• Brass inserts have the potential to store charge when they are not
plugged. Consideration should be taken to prevent these from
becoming a sparking hazard.
• Establish a procedure to routinely check the amplied speaker
system for proper activation and operation.
Failure to follow all safety precautions and instructions may result in
property damage, serious injury, or death.
Protection: Ex db IIB T5 Gb or Ex db e IIB T5 Gb
Ex tb IIIC T100°C Db IP66 (Tamb = -50°C to + 49°C)
Ex db IIC T4 Gb or Ex db e IIC T4 Gb
Ex tb IIIC T135°C Db IP66 (Tamb = -50°C to + 60°C)
1. The Modular Audible Device enclosure incorporates a sinter and
the volume is greater than 100 cm3, therefore use of the Modular
Audible Device in carbon disulphide gas atmospheres is not
permitted.
2. The Modular Audible Device has external non-metallic surfaces
which may provide electrostatic charging hazard. See the
manufacturer's instructions for further information.
6
Model G-SPA Global Series Amplied Speaker
Installation and Maintenance Instructions
3. The Modular Audible Device has metallic components in the non-
metallic walls of the enclosure which can store electrical charge
and therefore may provide a potential electrostatic discharge.
The metallic brass inserts have a capacitance of 24 pF. See the
manufacturer's instructions for further information.
Unpacking the Amplied Speaker
After unpacking the amplied speaker, examine it for damage that
may have occurred in transit. If it has been damaged, do not attempt to
install or operate it. File a claim immediately with the carrier, stating the
extent of the damage. Carefully check all envelopes, shipping labels,
and tags before removing or discarding them. Disposal of all shipping
materials must be carried out in accordance with national and local
codes and standards. If any parts are missing, please call Federal Signal
Customer Support at +1 708-534-4756 or +1 877-289-3246.
Creating Combination Fixtures in the Field
The Federal Signal Global Series Ex de products can be connected
together in the eld using interchangeable E-box end caps and a
proprietary coupling system.
The proprietary coupling system allows for simple and cost effective,
wiring from product to product often eliminating the need for
expensive Ex wiring practices and Ex rated glands. The E-box is
available only when factory installed on an Ex d unit or when used
as a E-box spacer adjoining an existing E-box. Please refer to the
accessories listed on page 25 for available options. When creating
certain xture combinations, it is necessary to replace E-box end caps
before mounting the product. If you are creating combination xtures,
refer to instruction manual 25500259 for specic instructions and
details.
A note about combination xtures: If the product is Ex db marked
only, it is for use in gas atmospheres. If the product is Ex db e marked,
it uses the increased-safety terminal enclosures and is only for gas
atmospheres. If the product is Ex tb marked, it is for installation in
dust atmospheres.
Model G-SPA Global Series Amplied Speaker
7
Installation and Maintenance Instructions
Figure 1 Beacon and amplied speaker combination xture
Mounting the Amplied Speaker
ATTACH THE AMPLIFIED SPEAKER SECURELY: To prevent injury,
this apparatus must be securely attached to the mounting surface
in accordance with the installation instructions. Use installersupplied fasteners suitable for the mounting surface.
The mounting method and the installer-supplied mounting hardware
depend on which of the three G-SPA models you are installing:
Mounting the Trunnion-Mount Amplied speaker
For the amplied speaker dimensions, see Figures 3 on page 9 and
4 on page 10. Mount the trunnion bracket to a at surface using
the two 7.0 mm mounting holes (Figure 2). Use installer-supplied
fasteners suitable for the surface to which the device will be
mounted.
8
Model G-SPA Global Series Amplied Speaker
Installation and Maintenance Instructions
60.0 mm
2X M6 SCREW HOLE
189.2 mm
To adjust the vertical angle of the amplied speaker, loosen
the fasteners on the mounting bracket to disengage the ratchet.
Vertically aim the amplied speaker, and tighten the fasteners.
Figure 2 Bracket dimensions
(2.36 in)
31.8 mm
(1.25 in)
Figure 3 Front view of trunnion-mount amplied speaker
(7.45 in)
215.2 mm
(8.47 in)
Model G-SPA Global Series Amplied Speaker
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.