Thank you for purchasing a Federal Industries display case. This manual contains important instructions for
installing and servicing the LPRSS Refrigerated Self-Service Merchandisers. A repair parts list and wiring
diagram are also included in the manual. Read all of these documents carefully before installing or servicing
your case.
NOTICE
Read this manual before installing your case. Keep this manual and refer to it before doing any
service on the equipment. Failure to do so could result in personal injury or damage to the case.
NOTICE
Installation and service of the electrical components in the case must be performed by a licensed
electrician.
The portions of this manual covering components contain technical instructions intended only for persons
qualified to perform electrical work.
DANGER
Improper or faulty hookup of electrical components in the case can result in severe injury or death.
All electrical wiring hookups must be done in accordance with all applicable local, regional, or
national standards.
SERIAL NUMBER
Record the model and serial numbers of the case for easy reference. Always refer to both model and serial
numbers in your correspondence regarding the case.
Case Model__________________________ Serial Number______________________
Condensing Unit Model________________ Serial Number______________________
This manual cannot cover every installation, use, or service situation. If you need additional information,
call or write us:
WARRANTY/TECHNICAL SERVICE DEPARTMENT
Federal Industries
P.O. Box 290
Belleville, WI 53508
Toll Free (800) 356-4206 / WI Phone (608) 424-3331
- 3 -
WARNING LABELS & SAFETY INSTRUCTIONS
This is the safety-alert symbol. When you see this symbol on your case or in the
manual, be alert to the potential for personal injury or damage to your equipment.
Be sure you understand all safety messages and always follow recommended precautions and safe
operating procedures.
NOTICE TO EMPLOYERS
You must make sure that everyone who installs, uses, or services your case is thoroughly
familiar with all safety information and procedures.
Important safety information is presented in this section and throughout the manual. The
Following signal words are used in the warning and safety messages:
DANGER: Severe injury or death will occur if you ignore the message.
WARNING: Severe injury or death can occur if you ignore the message.
CAUTION: Minor injury or damage to your case can occur if you ignore the message.
NOTICE: This is important installation, operation, or service information. If you ignore the
message, you may damage your case.
The warning and safety labels shown throughout this manual are placed on your Federal
Industries case at the factory. Follow all warning label instructions. If any warning or safety labels
become lost or damaged, call our customer service department at 1(800) 356-4206 for replacements.
CAUTION
RISK OF ELECTRIC
SHOCK DISCONNECT
POWER BEFORE
SERVICING UNIT.
91-12340
This label is located on the back of the display case. This label is located below the display pan.
CAUTION
HAZARDOUS MOVING PARTS
DO NOT OPERATE UNIT WITH
DISPLAY PANS REMOVED.
- 4 -
PRE-INSTALLATION PROCEDURES
Inspection for Shipping Damage
You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons
and crates for damage as soon as they arrive. If damage is noted to shipping crates, cartons, or if a
shortage is found, note this on the bill of lading (all copies) prior to signing.
If damage is discovered when the case is uncrated, immediately call the delivering truck line and
follow up the call with a written report indicating concealed damage to your shipment. Ask for an
immediate inspection of your concealed damage item. Crating material must be retained to show
the inspector from the truck line.
GENERAL ELECTRICAL & GROUNDING
DANGER: Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
Cord Connected
-All standard models are supplied with a power cord that is properly sized to the amperage requirements of
the case. See the electrical data plate located on the rear left interior of the case for the proper circuit size
for each case.
- The cord is factory installed protruding from the bottom rear corner of the case.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
Permanent Connected (OPTION)
-Only a licensed electrician must perform all case electrical connections.
-All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
-The electrical service must be grounded upon installation.
-See the electrical data plate located at the rear of the case for proper circuit size and wire ampacity.
-The electrical connection box is accessible from the rear of the case with rear grill removed.
REAR BASE
PANEL
(6) REAR BASE
PANEL SCREWS
POWER CORD OR
CONDUIT CONNECTION
FIELD CONNECTION BOX
- 5 -
HOLE (7/8"O)
INSTALLATION INSTRUCTIONS
Locating Display Case
The case should be located where it is not subjected to the direct rays of the sun, heating ducts, grills,
radiator, or ceiling fans, nor should it be located near open doors or main door entrances. Also, avoid
locations where there are excessive air movement or air disturbances.
The case requires a minimum of 6” clearance at the rear of the unit for air discharge. Do not locate case
with back tight against the wall. The louvers located on front of base must remain clear for air intake. If
rear clearance or front clearance is not possible see a Federal representative for air intake and discharge kit
options.
No clearance is needed on sides of the unit.
Removing Case From Shipping Skid and General Installation
CAUTION: Do not push or pull against the top panel, plastic end, end glass, or
door frames when removing the case from the skid or moving the case. Case
damage or glass breakage could result.
1. Remove crate top and sides and note missing or damaged items as explained in the pre-installation
procedures outlined above.
2. Move the case as near as possible to the final location and before removing it from the shipping skid.
3. Remove the (4) brackets that secure the case to the shipping skid.
4. Prepare cabinet according to instructions in this section that pertain to your model.
5. Lift the case off of skid and into required position. Only lift the case from under the rear lip and front
bottom trim channel above the base. Note: Do not push or pull on front bottom trim channel or lift
using the plastic end panel.
6. The case must be level for proper drainage of defrost condensate to the condensate evaporator. Using
the wrench provided level and square the case as needed by adjusting the leg leveler in each corner of
base. The 6’cases also have a set of leg levelers in the center. These must be adjusted so the base is flat.
The leveled case must be sealed to the floor using a NSF Listed Sealant.
7.
Cleaning
For initial setup, clean the case as outlined in the “Weekly Cleaning” section of this manual.
- 6 -
Center Panel Joining (Option)
If your cases where ordered with the Center Panel Joining Option you will need to perform the following
installation procedures.
REAR JOINING TRIM
CENTER PANEL
BASE MOUNTING
HOLES (4)
INTERIOR JOINING FLANGE
1. Place the right case into desired location and level case by adjusting leg levelers with provided
wrench.
2. Remove the front base panel (4) screws and rear base panels (6) screws from the left case. Push
the left case end tightly against the right case end. The rear joining trim on the right case must
be behind the back panel of the left case and the front joining bracket on the right case must be
inside the front aluminum trim channel of the left case.
3. Adjust the leg levelers on the left case so it is level and exactly aligned with the right case. The
(4) base mounting hole in the right case panel must align with the (4) mounting holes located in
base compartment of left case.
4. Push the cases together as tightly as possible and the gap between the cases must be tight and
even. If the gap is larger at the top or the bottom adjust leg levelers accordingly. HOLD CASES
TOGETHER AS TIGHT AS POSSIBLE WHILE ATTACHING ALL JOINING BRACKETS
AND DO NOT OVER TIGHTEN SCREWS OR SCREWS WILL STRIP OUT.
5. Attach the bottom of the left case to the right case center panel base mounting holes through the
holes located inside of the left case base. Use the (4) large 10-12x1/2 screws provided.
6. Attach the rear top of left case through the holes in the rear joining bracket using the (3) black
#10-12x1/2 self drilling screws provided.
7. Attach the front of left case through the holes in the front joining bracket using the (2) smaller
#8-12x1/2 self drilling screws provided.
8. Attach the top of left case through the holes in the top joining bracket using the (2) smaller
#8-12x1/2 self drilling screws provided.
9. Attach the interior of left case through the holes in the interior joining flange using the (3)
smaller #8-12x1/2 self drilling screws provided
10. If any there are any gaps along the joining seam fill them with NSF black silicone.
11. Reinstall front and rear grills.
RIGHT CASE
LEFT CASE REAR
BASE PANEL
TOP JOINING
BRACKET
FRONT JOINING
BRACKET
LEFT CASE
LEFT CASE FRONT
BASE PANEL
- 7 -
Refrigeration System:
Self Contained Models
The self-contained models are shipped from the factory with a completely operational 404A refrigeration
system and require no modifications or adjustments upon installation. Case must be installed as per the
installation section of this manual to provide proper condensing air cooling.
Remote Models
The remote models are designed to use 404A refrigerant and shipped from the factory with the evaporator
coil, expansion valve, sight glass, service valves and refrigerant solenoid valve. Installation must be
performed by a licensed Refrigeration Technician. See the Service section of this manual for installation
requirements.
Evaporater Condensate Drain Tube:
WARNING TO INSTALLER
Evaporator Condensate Drain Tube may become dislodged during shipping. Installer must
check Evaporator Condensate Drain Tube upon installation to be sure drain tube is
properly seated and installed correctly.
Evaporator Drain Tube must be attached to tube protruding from bottom of Evaporator Tub and must either
be inside the Condensate Pan area or inside of hole of Condensate Pump.
EVAPORATOR
CONDENSATE
DRAIN TUBE
EVAPORATOR
CONDENSATE
DRAIN TUBE
CONDENSATE PANCONDENSATE PUMP
- 8 -
Condensate Pump:
A condensate pump is Standard on some models and Optional on all models. Installer must check unit to
see if a condensate pump has been provided with case.
WARNING TO INSTALLER
Installer must determine if case was provided with condensate pump. Failure to hook up
pump hose to drain will cause water on floor and cause a slip hazard.
CONDENSATE PUMP
CONDENSATE
DRAIN TUBE
EXIT LOCATIONS
DRAIN TUBE
DRAIN TUBE
EXIT LOCATIONS
DRAIN TUBE
EXIT LOCATIONS
CONDENSATE PUMP
DRAIN TUBE
DRAIN TUBE
EXIT LOCATIONS
Instead of using heat energy to remove condensate run off from evaporator coil a condensate pump pumps
the water to a nearby drain.
-The Condensate Pump is provided with 50’ of clear 1/2 OD x 3/8 ID tubing that must be run out of base
area to a drain.
-There are several Drain Tube exit locations provided in base as noted in drawing above. Plugs or caps will
need to be removed in desired exit location.
-Hose can be run entire 50’ in any direction as required, but no higher than 20’ from pump base. A check
valve is provided in pump to prevent water from flowing back into reservoir. For best efficiency extend
hose level below or level of pump base to create a siphoning effect. Never run hose to or through an area
below freezing or freezing water will block tube.
- 9 -
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.