The Fedders multi-position air handlers, when
matched with our air conditioners or heat pumps,
offer a complete line of quiet, efficient split
systems for today’s heating and cooling equipment.
Easy To Install And Service
Performance
Dual rated 208/230 volt operation
1
⁄2 to 5 tons
1
External sweat refrigerant connections
TXV – factory installed standard, which precisely controls
refrigerant distribution for improved comfort and cost savings
Standard Features
Multiposition installation, upflow or horizontal left standard,
horizontal right and downflow with minor modifications
3-speed, permanently-lubricated PSC direct drive blower
motor is resilient mounted for ultra quiet, vibration-free
eration and flexible installation
op
Foil faced insulation reduces noise and bacterial growth and
features an easy to clean surface area
All indoor coils have copper tubing and aluminum fins
y relay comes standard and allows for retro-fit installations
la
e
ime D
T
imary and secondary drains on all models
r
3/4" p
MODELTONSREFRIGERANT
AFPB24A11.5 - 2R-22
AFPB24B11.5 - 2R-22
AFPB36A12.5 - 3R-22
AFPC48A13.5 - 4R-22
AFPC48B14R-22
AFPC60A15R-22
AZFPC60B15R-410A
AIR FLOW
RANGE
(CFM)
625 – 90043 3/8 x 18 x 2216 x 20 x 1115 / 109
615 – 88043 3/8 x 18 x 2216 x 20 x 1120 / 113
950 – 1,26043 3/8 x 18 x 2216 x 20 x 1120 / 113
1,190 – 1,59048 3/8 x 22 x 2620 x 25 x 1161 / 152
1,195 – 1,59048 3/8 x 22 x 2620 x 25 x 1167 / 160
1,340 – 1,89548 3/8 x 22 x 2620 x 25 x 1167 / 160
1,340 – 1,89548 3/8 x 22 x 2620 x 25 x 1167 / 160
Breaker accessible from front of unit when heater applied
External Access to heater circuit breakers pull /disconnects
Provisions for field installed electrical connections from
either side of air handler cabinet
Built in filter rack
Pressure taps on suction and liquid line
Corrosion resistant condensate drain pan. Primary and
secondary drain
Optional Features
Field installed heater packages from 5 kW – 20 kW
Warranty
5-year limited parts warranty
Rated in Accordance with ARI Standard 210/240.
Certification Applies Only When Used with
Proper Components as Listed with ARI.
Additional rating information
can be found at www.aridirectory.org
DIMENSIONS
H x W x D (in)
RECOMMENDED
FILTER SIZE
H x W x D (in)
SHIP/
OPERATIONS
WEIGHT (lbs)
Product Specifications
HYSICAL DATA
P
MODEL NUMBERAFPB24A1AFPB24B1AFPB36A1AFPC48A1AFPC48B1AFPC60A1AZFPC60B1
ELECTRIC DATA (208/230 VOLT, SINGLE PHASE, 60 Hz)
V
OLTAGE
MINIMUM CIRCUIT AMPACITY MCA (AMPS)
MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (AMPS)
B
LOWER
FAN MOTOR TYPEPSC
H
P
BLOWER DIMENSIONS9 x 79 x 79 x 10 9 x 89 x 810 x 9 10 x 9
SUCTION LINE CONNECTION SIZE (IN. OD)3/47/87/87/87/87/87/8
FIL
TER DATA
RECOMMENDED FILTER SIZE (H X W X D) (in)
(FILTER NOT SUPPLIED)
16 x 20 x 116 x 20 x 116 x 20 x 120 x 25 x 120 x 25 x 120 x 25 x 120 x 25 x 1
Clearance to Combustible Material
Clearances from the air handler to the combustibles are zero inches from all sides, top, and bottom; one inch from discharge
air plenum; and the duct within 36 inches of the plenum.
2
Specifications subject to change without notice.
Product Specifications
AIRFLOW PERFORMANCE
MODEL
NUMBER
AFPB24A1
AFPB24B1
AFPB36A1
AFPC48A1
AFPC48B1
AFPC60A1
AZFPC60B1
BLOWER
(INCHES WATER COLUMN)
SPEED
0.200.300.400.500.60
HIGH925900850795690
MEDIUM800760745670N/A
LOW655625600N/AN/A
HIGH905880830780680
MEDIUM785735730655N/A
LOW645615590N/AN/A
HIGH14401350126011801040
MEDIUM130012201050940860
LOW11601070950880780
HIGH16801640159015201430
MEDIUM14401410138013401250
LOW12401220119011501100
HIGH22302105199018951725
MEDIUM19501930184017701590
LOW13601360135013401080
MEASURED STATIC PRESSURE INLET TO OUTLET
Specifications applicable to upflow and horizontal applications.
Air flow shown at the following conditions:
- No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits.
- 60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations.
- Dry coil airflow shown.
3
Specifications subject to change without notice.
Accessories
ELECTRIC HEATER KITS
PART NUMBERDESCRIPTIONUSE WITH MODEL SIZE
EEC05N15 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL
EEC05B15 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL
EEC07N17.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKERALL
EEC07B17.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL
EEC10N110 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKERALL
EEC10B110 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL
EEC15B115 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
EEC20B120 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
AFPB36A1, AFPC48A1, AFPC48B1,
AFPB60A1, AZFPB60B1
AFPB36A1, AFPC48A1, AFPC48B1,
AFPB60A1, AZFPB60B1
ELECTRIC HEAT - ELECTRICAL DATA
kW
240
VAC
Phase
No. of
Supply
Circuits
MBTUH
208/240
Heat
Load
Amps
Min.
Wire À
Ampacity
SINGLE CIRCUIT SUPPLYDUAL CIRCUIT SUPPLY
Max.
Fuse Á
Wire Size ÂGround Size Á Min. Wire Ampacity À Max. Fuse Size ÁWire Size ÂGround Size Â
*kW does not include motor watts.
À Ampacities and over current protection based on largest air handler motor load. Refer to specific name plate for exact ampacity
and overcurrent protection size.
Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310,
for sizing conductors.
NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated.
Á Maximum size fuse or HACR-type circuit breaker for field wiring protection.
 Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit.
All wiring must conform to the National Electrical Code and all local codes.
/
MM2
4
Specifications subject to change without notice.
Product Specifications
LINE
VOLTAGE
KNOCKOUTS
LOW VOLT
E
B
D
C
CONNECTIONS
TO TXV
ACCESS COVER
G
INLET DEPTH
F
INLET WIDTH
I
H
A
DIMENSIONS
5
Specifications subject to change without notice.
Electric Air Handler
Residential & Light Commercial Air Handler
Model Number Identification
AFPB24A1* A
Product Type
A = Air Handler
Brand
R-22 Models
Motor
P = PSC
Chassis Size
B = 43 3/8"H x 18"W x 22"D
C = 48 3/8"H x 22"W x 26"D