Fedders AC1A User Manual

Residential & Light Commercial HVAC
AC1A Series Cased A-Coil
Upflow/Downflow, 11⁄2 thru 5 Tons
Fedders Cased Coils for use with the cool only condensing unit. This reliable matching cased coil was designed to compliment the Fedders full system.
T
e housed in a durable gauge painted cabinet and
ar fully insulated for quiet, efficient operation.
Performance:
Rated in accordance with ARI Standard 210/240
Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org
Easy To Install:
A-Coils offer low pressure drops to enhance system performance and airflow characteristics
Quality Built:
Coils have sweat fitting refrigerant connections
Widths match flush with Fedders gas furnaces
Primary and secondary condensate drain connections are 3/4" F.P.T. – Flush Mounted
Condensat heat r
Copper tube aluminum fin coil
All evaporators are factory leak-tested, dehydrated, seale
Pressure taps on suction and liquid line
TXV is standard on all coils
R4.0 insulation value in case All drain pans are compatible with UV lights Limit
e drain pan is constructed of high grade,
esistant,
d and ship
d 5-y
e
corrosion free material
ped with holding charge
y
ant
ear war
r
All tubing exits through left hand side of front access panel
Split seam front access
Suction and discharge line extend past the outside of the cabinet
Serviceability:
Front panel is removable for easy service and coil cleaning
Foil-Face insulation for easy cleaning
Product Specifications
OIL SPECIFICATIONS
C
YPE
MODEL
NUMBER
AC1A024A U, D 14.5, 16 600 - 900 4.00 14 3/8" 2 4 3/8" 3/4"
AC1A030A U, D 14.5, 16, 17.5, 20.5 800 – 1,250 3.11 14 3/8" 3 6 3/8" 7/8"
AC1A036A U, D 14.5, 16, 17.5, 20.5 1,000 – 1,400 4.00 14 3/8" 3 6 3/8" 7/8"
AC1A042A U, D 17.5, 20.5 1,300 – 1,500 4.89 12 3/8" 3 6 3/8" 7/8"
AC1A060A U, D 17.5, 20.5, 22 1,400 – 1,900 5.80 12 3/8" 3 6
*U = Upflow Applications. D = Downflow Applications. 1 = Requires a 1/2" - 3/8" reducer. 2 = Requires a 1 1/8" - 3/8" reducer.
MODEL
NUMBER
AC1A024A 0.10 0.11 0.12 0.13
AC1A030A 0.15 0.17 0.19 0.21
AC1A036A 0.19 0.20 0.22 0.23 0.24
AC1A042A 0.15 0.17 0.18 0.21
AC1A060A 0.21 0.23 0.23
T
AIR
FLOW*
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
FLUSH FIT TO
FURNACE
WIDTH
STATIC PRESSURE DROP THROUGH WET COIL & HOUSING (INCHES WATER COLUMN / CFM)
CFM
RANGE
ACE
F
AREA
SQ. FT.
INS
F
PER
INCH
TUBE
O.D.
UMBER
N
OF
ROWS
UMBER
N
OF
CIRCUITS
LINE
CONNECTIONS O.D.
LIQUID SUCTION
1
3/8"
7/8"
2
Airflow configurations (drawings showing different installation configurations) This product is ARI certified when matched with other Fedders products.
2
Specifications subject to change without notice.
Product Specifications
A
E
F
3
/4 NPT
DRAIN
B
D
3
/4 NPT
DRAIN PLUGGED
C
CASED COIL DIMENSIONS IN INCHES
MODEL
NUMBER
A B C D E F
SHIPPING
WEIGHT
(LBS)
AC1A024A14 14.5 20.0 21 3/4 NPT 13 20 42 22.8 24.2 16.4
AC1A024A16 16 18.5 21 3/4 NPT 14.5 20 43 21.3 24.2 17.9
AC1A030A14 14.5 20.0 21 3/4 NPT 13 20 44 22.8 24.2 16.4
AC1A030A16 16 18.5 21 3/4 NPT 14.5 20 45 21.3 24.2 17.9
AC1A030A17 17.5 18.5 21 3/4 NPT 16 20 46 21.3 24.2 19.4
AC1A030A20 20.5 18.5 21 3/4 NPT 19 20 51 21.3 24.2 22.4
AC1A036A14 14.5 20.5 21 3/4 NPT 13 20 51 22.8 24.2 16.4
AC1A036A16 16 18.5 21 3/4 NPT 14.5 20 52 22.8 24.2 17.9
AC1A036A17 17.5 18.5 21 3/4 NPT 16 20 52 21.3 24.2 19.4
AC1A036A20 20.5 18.5 21 3/4 NPT 19 20 53 21.3 24.2 22.4
AC1A042A17 17.5 23.5 21 3/4 NPT 16 20 55 26.3 24.2 19.4
AC1A042A20 20.5 23.5 21 3/4 NPT 19 20 58 26.3 24.2 22.4
AC1A060A17 17.5 22.5 24 3/4 NPT 16 23 65 25.7 27.2 19.4
AC1A060A20 20.5 22.5 24 3/4 NPT 19 23 67 25.7 27.2 22.4
AC1A060A22 22 22.5 24 3/4 NPT 20.5 23 69 25.7 27.2 23.9
SHIPPING DIMENSIONS
HEIGHT LENGTH WIDTH
3
Specifications subject to change without notice.
AC1A Series Cased A-Coil
COIL NOMENCLATURE
A C 1 A 036 A 14 * A
Brand Coil
A = Fedders Coil
Case Designation
C = Cased Coil
Position
1 = Upflow/Downflow
Design Series
A = A Series
Nominal Capacity
024 = 18,000/24,000 BTUH [5.28/7.03 kW] 030 = 30,000 BTUH [8.79 kW] 036 = 36,000 BTUH [10.55 kW] 042 = 42,000 BTUH [12.31 kW] 048 = 48,000 BTUH [14.07 kW] 060 = 60,000 BTUH [17.5 kW]
Casing W
idth
14 = 14.5" Casing Width 16 = 16" Casing Width 17 = 17.5" Casing Width 20 = 20.5" Casing Width 22 = 22" Casing Width
Major Revision
A = First Revision
Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 USA (908) 604-8686 Form No. F-Acoil-0407B
All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.
FD-016 -0407B
4
Specifications subject to change without notice.
Loading...