Residential & Light Commercial HVAC
AC1A Series Cased A-Coil
Upflow/Downflow, 11⁄2 thru 5 Tons
Fedders Cased Coils for use with the cool only
condensing unit. This reliable matching cased coil
was designed to compliment the Fedders full system.
he coils are available for use in R-22 systems. They
T
e housed in a durable gauge painted cabinet and
ar
fully insulated for quiet, efficient operation.
Performance:
Rated in accordance with ARI Standard 210/240
Rated in Accordance with ARI Standard 210/240.
Certification Applies Only When Used with
Proper Components as Listed with ARI.
Additional rating information can be found
at www.aridirectory.org
Easy To Install:
A-Coils offer low pressure drops to enhance system
performance and airflow characteristics
Quality Built:
Coils have sweat fitting refrigerant connections
Widths match flush with Fedders gas furnaces
Primary and secondary condensate drain
connections are 3/4" F.P.T. – Flush Mounted
Condensat
heat r
Copper tube aluminum fin coil
All evaporators are factory leak-tested, dehydrated,
seale
Pressure taps on suction and liquid line
TXV is standard on all coils
R4.0 insulation value in case
All drain pans are compatible with UV lights
Limit
e drain pan is constructed of high grade,
esistant,
d and ship
d 5-y
e
corrosion free material
ped with holding charge
y
ant
ear war
r
All tubing exits through left hand side of front access panel
Split seam front access
Suction and discharge line extend past the outside of
the cabinet
Serviceability:
Front panel is removable for easy service
and coil cleaning
Foil-Face insulation for easy cleaning
Product Specifications
OIL SPECIFICATIONS
C
YPE
MODEL
NUMBER
AC1A024A U, D 14.5, 16 600 - 900 4.00 14 3/8" 2 4 3/8" 3/4"
AC1A030A U, D 14.5, 16, 17.5, 20.5 800 – 1,250 3.11 14 3/8" 3 6 3/8" 7/8"
AC1A036A U, D 14.5, 16, 17.5, 20.5 1,000 – 1,400 4.00 14 3/8" 3 6 3/8" 7/8"
AC1A042A U, D 17.5, 20.5 1,300 – 1,500 4.89 12 3/8" 3 6 3/8" 7/8"
AC1A060A U, D 17.5, 20.5, 22 1,400 – 1,900 5.80 12 3/8" 3 6
*U = Upflow Applications. D = Downflow Applications.
1 = Requires a 1/2" - 3/8" reducer.
2 = Requires a 1 1/8" - 3/8" reducer.
MODEL
NUMBER
AC1A024A 0.10 0.11 0.12 0.13
AC1A030A 0.15 0.17 0.19 0.21
AC1A036A 0.19 0.20 0.22 0.23 0.24
AC1A042A 0.15 0.17 0.18 0.21
AC1A060A 0.21 0.23 0.23
T
AIR
FLOW*
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
FLUSH
FIT TO
FURNACE
WIDTH
STATIC PRESSURE DROP THROUGH WET COIL & HOUSING (INCHES WATER COLUMN / CFM)
CFM
RANGE
ACE
F
AREA
SQ. FT.
INS
F
PER
INCH
TUBE
O.D.
UMBER
N
OF
ROWS
UMBER
N
OF
CIRCUITS
LINE
CONNECTIONS O.D.
LIQUID SUCTION
1
3/8"
7/8"
2
Airflow configurations (drawings showing different installation configurations)
This product is ARI certified when matched with other Fedders products.
2
Specifications subject to change without notice.