Room Air Conditioners
for Through-The-Wall
Installation
Please read the operating instructions and
safety precautions carefully and thoroughly
before installing and operating your air
conditioner.
ENGLISH PAGE 1
Acondicionadores de
aire empotrados
en la pared
Por favor lea las instrucciones de operación y
las precauciones de seguridad cuidadosa y
totalmente antes de instalar y operar su
acondicionador de aire de ventana.
ESPAÑOL PÁGINA 13
Climatiseur d’air
E
N
G
L
I
S
H
individuel pour
installation murale
dans une gaine
euillez lire attentivement et en entier ce
V
guide d’utilisation et les mesures de sécurité ciincluses avant de procéder à l’installation et au
fonctionnement de votre climatiseur
FRANÇAIS PAGE 25
.
Table of Contents
Electrical Requirements &
Safety Precautions
Power cord with arc detection device ............................ 1
Important grounding requirements ................................ 2
Electric shock hazard ........................................................2
Power Cord with Arc Detection Device
he power cord supplied with this air conditioner is
T
equipped with an Arc Detection Device designed to
hut off power to the unit when it senses an arc fault
s
condition. An arc fault is an unintentional electrical
discharge that occurs when electrical products or
wires are damaged, aged, or improperly used. An arc
ault can be potentially hazardous if left undetected.
The model and serial numbers can be found on the side of the
cabinet near the control panel. Use these numbers in any
correspondence or service calls concerning your air conditioner.
Model No.
......................11
WARNING
• Do not remove or modify this plug
• Do not use as an on/off switch
• Do not use outdoors
Do not
•
the electrical cord. This can trip the test switch
and/or damage the cord and become a potential
condition for arcing
• Do not attempt to repair the cord. If the cord requires
replacement, call an authorized servicer.
• The Arc Detection Device is not a Ground Fault
Interrupter and should not be used as such
• The Arc Detection Device contains an electronic
circuit board and should not be submerged or
exposed to water spray
Resetting
If the Arc Detection Device has tripped, the reset
button will pop up.
Follow these steps to reset the Arc Detection Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Check to see if power has returned to the unit
Testing
You should test the Arc Detection Device equipped
power cord monthly
or if power to your Room Air Conditioner has been
interrupted.
Follow these steps to test the Arc Detection Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4.
5.
If above test fails, stop using the air conditioner and
contact customer service
free number:
or email: customerservice@fedders.com
push furniture against or place furniture on
, after every major electrical storm,
Press test button. Unit should trip and reset button
will pop up.
Press reset button again for use
by calling the following toll-
1-800-332-6658
Serial No.
Date of Purchase
Keep these instructions for future reference.
1
Warning
o notoperate this air conditioner
D
ithout proper time delay circuit
w
protection (circuit breaker or fuse).
Refer to serial plate for proper power
supply requirements.
Recommended Wire Sizes
(As installed per building code) :
PROTECTOR SIZEWIRE GAUGE
• Plug unit only into a
grounded electrical outlet.
•
Do not use an extension cord or plug
adapter with this unit.
o notoperate unit with decorative
D
•
front or filter removed.
•
Failure to follow these precautions
could result in electrical shock, fire or
personal injury.
• If the air conditioner has a serial plate
rating of 115 volts and greater than 7.5
amps, it must have its own fuse or
circuit breaker, and no other device or
unit should be operated on that fuse
or circuit breaker.
• If the air conditioner has a serial plate
rating of 230 volts, it must have its
own fuse or circuit breaker, and no
other device or unit should be
operated on that fuse or circuit
breaker.
• We recommend that a qualified
electrician install unit in accordance
with the National Electrical Code and
local codes and ordinances.
• Use copper conductors of correct wire
gauge and protector size only.
•
Do not alter cord or plug end. Do not
remove warning label on cord.
Important Grounding Requirements
• Air conditioner has a three-prong
grounding plug on the power supply
cord, which must be plugged into a
properly grounded three-prong wall
receptacle for your protection against
possible shock hazard. For models up
to and including 7.5 amperes, use a
grounding type wall receptacle to
match the cord plug.
• For models above 7.5 amperes use a
single outlet grounding type wall
receptacle to match the cord plug.
Additional Safety Precautions
• Do not cut, alter or remove any of
the expanded polystyrene
(styrofoam) inside this air
conditioner.
•
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or any
other appliance. The fumes can
create a fire hazard or explosion.
•
Do not introduce objects in the air
discharge area. This could cause
permanent damage.
•
Do not pour liquids on the air
conditioner as this could cause a
malfunction. With the unit
unplugged, use a damp cloth for
cleaning the unit.
Do not use strong solvents to clean
•
the air conditioner.
Clean the air conditioner filter
•
every two weeks to avoid
overheating caused by air
obstruction. Do not operate
without filter.
Do not obstruct the air intake area
•
of your air conditioner, as this
could cause overheating, thus
activating the unit’s security switch
and shutting off the unit.
Do not block air circulation to
•
outside louvers of cabinet.
•
Do not block air flow inside with
blinds, curtains, or furniture, or
outside with shrubs, enclosures, or
other buildings.
Do not run the air conditioner with
•
an outside protective cover in
place. This could result in fire or
mechanical damage within the air
conditioner
• Depending on the model, your air
conditioner may weigh as much as
95 pounds. To insure safe handling,
obtain the necessary help to lift
and position the unit during
installation and removal.
• Handle air conditioner with care.
Wear protective gloves whenever
lifting or carrying the unit.
Carefully inspect the location
•
where the air conditioner will be
installed. Be sure it will support the
weight of the unit over an
extended period of time.
.
E
N
G
L
I
S
H
2
Before you start
You have purchased a Through-the-Wall style air conditioner.
This type of air conditioner is designed to be installed inside
wall sleeve mounted into a wall opening.
a
Tools Needed
Phillips screwdriver
ule or tape measure
R
Level
nstallation Requirements
I
Check the location where the air conditioner will be
installed. Proper installation is your responsibility. Make
sure you have read the instructions thoroughly and have
everything necessary for correct installation.
he location should provide:
T
• Grounded electrical outlet within 4 ft. (122 cm) of
where the power cord exits the air conditioner.
NOTE: DO NOT USE AN EXTENSION CORD.
• Free movement of air in room to be cooled.
• A large enough opening for the air conditioner and
sleeve.
• Adequate wall support for weight of air conditioner
over an extended period of time.
You may also need a drill with 1/8” or smaller bit,
depending on your installaton requirements.
Installation Parts
Several components are included with your air conditioner
to complete a successful installation. Please compare the
contents of the carton with this illustration.
Through-the-wall air
Trim frame
(4 pieces)
conditioner
Wall Opening
Width: 27”
Wall Sleeve (sold separately)
Fedders wall sleeve (A70052) includes
front and rear covers, plus a rear grille.
vailable through your local distributor.
A
Sleeve dimensions: 26
Height 16”
3
/4”W x 15”D x 153/4”H
# 8-32 self tapping
Phillips head screws
(6 pieces)
Trim frame
insulation foam
(2 pieces)
20” x 1/2” x 1/8”
3
Rear Grille: This rear grille is designed
to achieve maximum performance from
your new air conditioner. This new
grille should be installed in all wall
sleeves. Failure to install this rear grille
will void your air conditioner warranty.
nstalling the rear grille into a
INSTALLATION
I
new wall sleeve:
A new Fedders Wall sleeve (sold separately) will ensure the
best fit and performance of your new through-the-wall air
conditioner. See your local Fedders dealer or distributor
about purchasing wall sleeve model A70052. To locate a
dealer in your area, call 1-800-332-6658.
Follow the installation instructions that are included with
your new wall sleeve.
If you have a new Fedders wall sleeve already installed in
the room with front and rear covers in place, you may
complete the installation by attaching the rear grille.
To Install the rear grille into a new Fedders wall sleeve:
1. Remove the front and back covers of the new wall
sleeve. Save the covers for future use to seal the wall
sleeve if the air conditioner is removed.
2. Clean out any debris from inside the wall sleeve, making
sure the inside is clean and that the drain holes are
completely open.
3. Insert the new grille into the wall sleeve. (Fig. 1)
4. Secure the grille to the sleeve with six (6) screws
(provided) through the holes in the grille and into the
sleeve. (Fig. 2)
Warning: Install the new grille that came with
your unit or new Fedders sleeve. If this rear grille
is not installed in the wall sleeve, your unit will
not operate correctly and the warranty will be
void.
Both the air conditioner and the wall sleeve come
with the rear grille. If you have ordered both
items, you may discard the extra grille.
1
Wall sleeve
2
View from inside
of room
Rear grille
*
E
N
G
L
I
S
H
# 8-32 self tapping
Phillips head screws
(6 pieces)
*Note: Make sure that the word “T
stamped into the rear grille, can be read
from inside the room.
op”,
4
nstalling the rear grille into an
I
existing wall sleeve:
1. Measure the dimensions of your existing wall sleeve. (Fig. 3)
2. Locate your wall sleeve in the wall sleeve identification chart
below.
If you have any questions or if your sleeve is not listed please
call 217-347-6459 or email customerservice@fedders.com.
You must install the new grille included with your air
conditioner. Failure to do so could damage the unit
and will void the warranty.
Wall sleeve identification chart
Determine the type of wall sleeve you have from the chart below
and follow the instructions and warnings in the section indicated.
3
Height
W
idth
Wall Sleeve
Depth
Dimensions of wall sleeveFollow instructions
WidthHeightDepth
25 7/8” 18” 15 9/16”Carrier (52F series)
25 3/4” 18 5/8”16 7/8”Carrier (51S Series)
26 3/4” 15” 15 3/4”Emerson Quiet Kool
26 3/4” 15” 15 3/4”Fedders
27” 16 3/4” 16 3/4”Fedders “A” chassis (BSA000D)
27” 19 3/4” 16 3/4”Fedders “B” chassis (BSB000D)
27” 16 3/4” 16 3/4”Friedrich
25 7/8”16”/18”/22”15 7/8”Frigidaire
26” 16 7/8” 15 5/8”General Electric/Hotpoint
25 7/8” 16 23/32” 15 17/32” LG
26 3/4” 15”15 3/4”Maytag
25 1/2” 19”15 5/8”Sears
25 1/2” 22 9/16” 15 5/8”Sears
27 3/8” 15 3/4”16”Welbilt
25 1/2”
25 1/2” 19” 15 5/8”Whirlpool
22 9/16”
15 5/8”
Whirlpool
Wall Sleeve
Manufacturer
under section
Section B
Section B
Section A
Section A
See note below
See note below
See note below
Section B
Section C
Section B
Section A
Section A
Section A
See note below
See note below
Section A
25 1/2”
22”
15 1/4”
White-W
If your existing sleeve is 27"wide or greater, STOP HERE.
These sleeves require a larger rear grille than the one provided with this unit and dif
installation parts. Y
Included in the kit is a rear grille, larger trim frame, rear air deflector
pieces that will be needed to correctly install your air conditioner in a wall sleeve that is 27
inches wide or greater than 27 inches. Please contact the distributor where you purchased the
unit. If you do not install your new air conditioner using this kit you will cause damage to the
Warning:
This type of sleeve will require you to remove the existing
rear grille and install the new grille that came with your
unit. If this new rear grille is not installed in the wall sleeve
your unit will not operate correctly and the warranty will be
void.
1. Remove screws attaching the existing grille to the wall sleeve.
2. Remove the existing grille.
3. Clean out any debris.
4. Insert new grille into sleeve. (Fig. 4)
Note: Make sure that the word “Top” can be read from inside
the room.(Fig. 5)
5. Secure the grille to the back of the sleeve with the six (6)
screws (provided). The screws will attach through the holes in
the grille and into the corresponding holes in the sleeve.
(Fig. 5)
Wall Sleeve
anufacturer
M
Fedders
4
Wall sleeve
5
View from inside of room
Rear grille
E
N
G
L
I
S
H
# 8-32 self tapping
Phillips head screws
(6 pieces)
Warning:This type of sleeve will require you to remove the old
ear grille and install the new grille that came with your unit. If
r
this rear grille is not installed in the wall sleeve your unit will not
operate correctly and the warranty will be void.
1. Remove the existing rear grille from the wall sleeve.
2. Clean out any debris.
3. Remove tabs on sides of the grille provided with your new unit by
bending tabs back and forth using a pair of pliers. W
protect your hands from sharp edges. (Fig. 6)
4. Insert new grille into sleeve. (Fig. 7)
Note: Make sure that the word “Top”, stamped into the rear grille,
can be read from inside the room.
5. Secure the new rear grille to the sleeve by using the screws
(provided) in the same locations as the screws that secured the old
rear grille.
ear gloves to
Section C
Dimensions of wall sleeve
WidthHeightDepth
26” 16 7/8” 15 5/8”General Electric/Hotpoint
Warning:
This type of sleeve will require you to remove the old rear grille
and install the new grille that came with your unit. If this rear
grille is not installed in the wall sleeve your unit will not operate
correctly and the warranty will be void.
1. Remove the existing grille from the wall sleeve.
2. Clean out any debris.
3. Remove the tabs on the sides of the grille provided with your new
unit by bending the tabs back and forth using a pair of pliers.
Wear gloves to protect your hands from sharp edges. (Fig. 6)
4. Insert new grille into sleeve. (Fig. 7)
Note: Make sure that the word “Top”, stamped into the rear grille,
can be read from inside the room.
5. Mark the locations of two holes on the top of the wall sleeve.
Using these marks as a guide, drill holes into the sleeve using a
1/8” drill bit. Attach the rear grille using the supplied screws.
(Fig. 8)
Wall Sleeve
Manufacturer
Rear grille
7
Rear grille
8
Drill 1/8” holes through wall sleeve and
attach rear grille with # 8-32 self tapping
Phillips head screws (provided).
Wall sleeve
7
Installing the air conditioner into the wall sleeve
INSTALLATION
1. Replace any damaged foam inside the wall sleeve with
replacement foam. Two pieces of adhesive backed
replacement foam are provided, one vertical piece (15 3/4” x
3/4” x 1”) and one horizontal (25” x 3/4” x 1”).
2. Depending on the model, your air conditioner may weigh as
much as 95 pounds. To insure safe handling, obtain the
necessary help to lift and position the unit during installation
and removal.
3. Slide air conditioner fully into the sleeve. (Fig. 9) The air
conditioner should be centered in the sleeve so that all seals
bear evenly to prevent air leakage. NOTE: THE UNIT IS
APROX. 6” DEEPER THAN THE SLEEVE. THE UNIT WILL
PROTRUDE APROX. 6” FROM THE SLEEVE INTO THE ROOM.
When installation is complete, the unit must have a
rearward slope to prevent condensate water from
entering the room. (Fig. 10) Check with a level.
9
10
Air conditioner
(inside of room)
Rearward
slope
all sleeve
W
Air conditioner
Wall
sleeve
(outdoors)
E
N
G
L
I
S
H
Installing the trim frame
The trim frame covers any gaps between the wall sleeve and the
air conditioner.
1. Assemble trim frame by laying the 4 frame pieces face down
on a flat surface and snapping them securely together.
(Fig. 11)
2. Install the 20” x 1/2” x 1/8” adhesive backed insulating foam
around the inside edge of the trim frame. Begin in the
bottom left corner and place the insulating foam around the
entire inside of trim frame.
Slide the trim frame onto the air conditioner until the foam
3.
makes a seal with the wall sleeve. (Fig. 12)
12
11
Trim frame
all sleeve
W
Trim frame foam
(2 pieces)
20” x 1/2” x 1/8”
rim frame
T
8
Set
Temperature/
Timer Display
Temperature/
imer Hour
T
Controls
Timer
Control
Fan Speed
Control
Mode
Control
Power
Control
Built-in three minute timing delay.
If the electronic controls do not respond to
touch pad or remote control commands, you
must unplug the unit from the electrical outlet
for five seconds and then plug the unit back in.
Auto restart feature:
In the event of a power failure, this feature allows
the unit to resume operation once power has been
restored, retaining the most recent settings. Upon
restoration of power, the timer mode may need to
be reset if being utilized.
CAUTION
Heat/Cool models or units with electric heat
are designed to be used only as a
supplemental heat source. They should be
used in addition to regular heating systems
and never as the primary source of heat.
Power Control
The Power Control turns the unit on and off.
Set Temperature/Timer Display
he Set Temperature/Timer Display shows the set temperature when the unit
T
is in operation and hours when the timer is being set.
HE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT THE
T
ACTUAL ROOM TEMPERATURE.
Temperature/Timer Hour Controls
These buttons are used to raise or lower the set temperature. By depressing
oth buttons at once, the display will toggle between Celsius and Fahrenheit.
b
When the timer is being set, these buttons are used to change the hour
setting.
Mode Control Fan, Cool, Heat (Heat models only), and Energy Save.
A green light will indicate which mode is currently being utilized.
Cool Mode – The unit will circulate and cool the air.
Fan Mode – The unit will only circulate the air.
Heat Mode (Heat models only)- The unit will circulate and heat the air.
Heater Safety Feature- When heater is powered off, low fan will
automatically stay on and run for 60 seconds to ensure the removal of
residual heat, meanwhile, the Low Fan LED blinks until the low fan
stops.
Energy Save Mode – The fan will switch from the set fan speed to Low
whenever the compressor turns off in response to the thermostat. When
the compressor cycles back on, the unit will return to the original fan
setting.
Fan Speed Control
High, Medium*, Low and Auto
The settings are adjusted with the Fan Speed Control, each time the button
is depressed it changes the setting. A green light will indicate which setting
is currently being used.
When the AUTO feature is selected while the air conditioner is in the COOL
or HEAT mode, the fan speeds will change automatically as the temperature
in the room changes.
COOL Mode
• 7° or more above the set temperature will use HI fan.
• 4° or less above the set temperature will use LO fan.
HEAT Mode
• 9° or more below the set temperature will use HI fan.
or less below the set temperature will use LO fan.
°
4
•
*MEDIUM FAN NOT available on HEAT models.
Timer Control
The timer can be set to either turn the unit on or off.
o turn the unit on using the Timer:
T
Depress the timer key when the power is off, the display will read 00. Adjust
to the desired number of hours before TURN ON using the up/down arrows.
•The display will show the time by hours left until TURN ON.
urn the timer of
o T
•T
•A green light next to the Timer Control indicates that the timer is set.
To turn the unit OFF using the Timer:
Depress the timer key when the power is on, the display will read 00. Adjust
to the desired number of hours before TURN OFF using the up/down arrows.
The display will automatically go back to the set temperature after 10
seconds.
•To display the amount of time left until TURN OFF, depress the timer button
once.
o turn the TIMER
•T
•A green light next to the Timer Control indicates that the timer is set.
f, depress the timer key.
OFF, depress the timer button twice.
9
irecting Airflow
AAA
IEC R031.5V
+
-
AAA
IEC R03
1.5V
OPERATION
T
&
SAFETY PRECAUTIONS
I
D
(Unit with adjustable louvers)
The unit includes adjustable louvers to direct discharge airflow.
Louvers are manually adjusted by moving the levers in the direction
of desired airflow. (Fig. 13)
Air Conditioner Remote Control
The functions on the remote control work the same as your air
conditioner’s touch controls. For a full explanation of these controls
please see the previous page .
On/Off
The On/Off button is used to turn the unit on or off.
Temp/Time
The Time/Temp buttons are used to raise or lower the set
temperature. These buttons are also used to set the timer.
Mode
The Mode button changes the operational mode. Available modes
are: Fan, Cool, Heat (Heat models only), and Energy Save.
Fan Speed
Each time the button is depressed it changes the fan speed setting.
Available fan speeds are High, Low, and Auto.
Timer
The timer button accesses the timer function which can be set to
either turn the unit on or off.
CAUTION:
Use only AAA or IEC R03 1.5V batteries.
•
• Remove the batteries if the remote control will not be used for
a month or longer.
Do not attempt to r
•
• All batteries should be replaced at the same time.
• Do not dispose of the batteries in a fire as they may explode.
Do not mix old and new batteries.
•
• Do not mix alkaline, standard (carbon - zinc), or rechargeable
(nickel-cadmium) batteries.
Do not install the batteries with the polarity (+/–) r
•
• Keep batteries and other objects that could be swallowed away
om young childr
fr
is swallowed.
echarge the supplied batteries.
eversed.
en. Contact a doctor immediately if an object
13
Adjustable louver
14
Battery replacement:
Remove the cover
on the back of the
remote control and
insert the batteries
with the (+) and (-)
poles pointing in the
proper direction.
Screwdriver required
to remove battery
.
cover
E
N
G
L
I
S
H
10
leaning the air filter
C
VERY TWO WEEKS: Clean the filter.
E
15
Air filter
1. Turn Power OFF.
. Remove the air filter by grasping the top corners and pulling
2
it up and out of the unit. (Fig. 15)
. Wash in hot soapy water, rinse and shake dry.
3
4. Replace the filter with the front of the filter toward you.
5. To dry the filter thoroughly, run your unit in fan mode for a
few minutes. Remember, only a clean filter works properly
nd delivers top efficiency at every setting.
a
Note: Failure to keep air filter clean will result in poor air
irculation. DO NOT operate without filter. This can render the
c
unit inoperative.
Proper use and care of your air conditioner will help ensure
longer life of the unit. It is recommended to have a
professional annually inspect and clean the coils and
condensate water passages. Expense of annual inspection is
the consumer’s responsibility.
Troubleshooting Guide
OccurrencePossible CauseSolutions
Air conditioner will not operate• Wall plug disconnected.• Push plug firmly into wall outlet.
• House fuse blown or circuit breaker tripped.• Replace fuse with time delay type
or reset circuit breaker.
• Power control in OFF position.
• Unit accidentally turned off by moving the • Wait approximately 3 minutes.
thermostat to a higher temperature and thenListen for the compressor to start.
immediately turned back to a colder position.
• Unit turned off and then on too quickly.
• Thermostat set too low for cooling.
• Turn power control to ON.
• If air conditioner is turned off,
wait 3 minutes before restarting.
• Adjust thermostat to higher setting for cooling.
Decorative front
Air from unit does not • Selector in fan position.• Set mode to cool position.
feel cold enough• Thermostat set too warm.• Set thermostat to colder temperature.
• Room temperature below 70°F.• Cooling may not occur until room
temperature rises above 70°F.
Air conditioner cooling,• Outdoor temperature below 70°F.• To defrost the coil, set selector to FAN position.
but room is too warm —Then, set thermostat to warmer position.
ice forming on cooling coil• Dirty air filter — air r
behind decorative frontTo defrost, set selector to FAN.
• Thermostat set too cold for nighttime cooling.• To defrost the coil, set selector to FAN position.
Air conditioner cooling,• Dirty air filter — air restricted.• Clean air filter. Refer to“Cleaning the air filter”
but room too warm — section (above).
NO ice forming on cooling coil• Thermostat set too warm.• Set thermostat to colder setting.
behind decorative front• Fan selector set on LOW.• Set fan speed selector to HIGH
Noise when unit is cooling• Air movement sound.• The sound of rushing air is normal. If too loud,
• Sound of fan hitting water-moisture • This is normal when humidity is high.
emoval system.
r
indow vibration — poor installation.
• W
Water dripping inside• Improper installation.• Tilt air conditioner slightly to the outside to
when unit is coolingallow water drainage. Refer to installation
ater dripping outside
W
when unit is coolingfr
emoving large quantity of moistur
• Unit r
om humid r
oom.
estricted.
• Clean filter
turn selector to lower fan setting.
• Refer to installation instructions —
e
• This is normal during excessively humid days.
. See “Cleaning the Air Filter” section.
for maximum cooling.
Close doors, windows and r
check with installer.
instructions — check with installer.
egisters.
11
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.