FDK FT-C21Y, FT-C23Y, FT-C22Y, FT-C24Y, FTC11B User Manual

...
Arm Automatic Blood Pressure Monitor
(Electronic Sphygmomanometer)
User Manual
Thank your for purchasing our product.
Please read this manual carefully before using the product.
Please keep the manual appropriately for future reference.
This User Manual is suitable to the following models: FT-C21Y, FT-C22Y, FT-C23Y,
FT-C11B-V, FT-C12B-V, FT-C11B-UR and FT-C11B-BT.
Table of Contents
(I) General Information
(II) Precaution for Use and Maintenance
(III) Name of Each Part
(IV) Measure Procedure
(V) Troubleshooting
(VI) Model List
I. General Information
Intended Use
Fudakang Arm Automatic Blood Pressure Monitor is intended for use by medical
professionals or at home to monitor and display diastolic, systolic blood pressure and
pulse rate on adult each time, with an air cuff buckled around one's arm according to the
instruction in the user's guide manual.
Indications For Use
Fudakang Arm Automatic Blood Pressure Monitor is for use by medical professionals or
at home and is a non-invasive blood pressure measurement system intended to measure
the diastolic and systolic blood pressures and pulse rate of an adult individual by using a
non-invasive technique in which an inflatable cuff is wrapped around the arm. The cuff
circumference is limited to 8.7 inches to 12.6 inches.
Specification
Product Name
Applied Models
Measurement Principle Oscillography
Bluetooth Version
Bluetooth Modulation Type GFSK
Cuff
Measurable Arm Circumference Range
Measurement Range
Accuracy
Power Supply 4 x 1.5V AA Alkaline batteries 6V
Arm Automatic Blood Pressure FT-C21Y, FT-C22Y, FT-C23Y, FT-C24Y, FTC11B,
FT-C12B, FT-C21Y-V, FT-C22Y-V, FTC23Y-V,
FT-C24Y-V, FT-C11B-V, FT-C12B-V, FT-C11B-UR
and FT-C11B-BT.
Bluetooth 4.0 BLE
Soft cuff, Cuff size 480mm×140mm (+/- 5mm)
18.89 × 5.51 inch (+/- 0.19 inch)
About 220~360mm (8.6 6~ 14.17 inch)
Pressure: 0~280mmHg Pulse: 30~160 times/minute
Pressure: ±3mmHg Pulse: ±5%
Battery Life Approx. 250 times (180mmHg, 1 time/day, 22°C)
Each measurement takes around 60 seconds, and
each memory checking takes about 1 second
Protection against electric shock
Type BF Cuff
IP classification IP21
Temperature: 10~40°C
Working Environment
Humidity: ≤85%RH Pressure: 86~106 kPa
Transport and storage Environment
Temperature: -20~60°C Humidity: 85% RH Pressure: 86~106 kPa
Electric Shock Protection Internal power unit
Memory Capacity
2 Memory sets ; each 90 reading of data including date and time
Inflation Automatic Inflation by internal pump
Deflation
Display
Color Backlight display on LCD (Optional)
Automatic speed deflation system controlled by internal electromagnetic valve.
LCD digital display ; It can show Pressure, Pulse, Date, Time White backlight display when power on Green backlight display when result is normal Red backlight display when result is abnormal
Switch 3(ON/OFF, Memory, SET)
Machine : 5 years or 10000 times
Life Time
Cuff : 10000 times AC Adapter: 50000 hours
-Cuff
Contents
-4 x1.5V AA alkaline batteries 6V (Optional)
-Carrying bag(Optional)
-Instruction Manual
Note:
These specification may be changed without prior notice.
Contraindications:
1. Heart disease
2. High blood pressure or other circulatory disease
3. Arm injury
Patient Populations:
The device is intended to use for adults. DO NOT use this device on infants or small
children..
Cleaning Information:
1. If the device is very dirty, wipe it clean with a cloth moistened with sterilizing alcohol or
a neutral detergent. Then wipe it with a dry cloth.
2. NEVER clean the blood pressure monitor with thinners or benzene, as they may
damage it.
3. To clean the cuff, wipe it with a moist cloth. Avoid hard rubbing as this will cause air
leakages. Take care also not to get water into the air hose.
Maintenance:
This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every five years to ensure proper function and performance. The device doesn’t need to be calibrated in five years of reliable service. Modification of this equipment is allowed except change the batteries.
Protect the Nature Environment:
Please help to protect natural environment by respecting national and/or local recycling
regulations when disposing of the battery and the product at the end of their useful live.
II. PRECAUTION FOR USE AND MAINTENANCE
Precautions for Use:
1. If you suffer from heart disease, high blood pressure or other circulatory disease,
consult your physician before using the device. It is intended for adult indoor use
only. The device is not suitable for public use.
2. The patient is an intended operator. The patient can measure, transmit data and
charge battery under normal circumstances and maintain the device and its
accessories according to the user manual.
3. If the cuff pressure feels abnormal or you experience any other irregularity while using
the cuff, reduce the pressure immediately by pressing the “ON/OFF” switch and then
consult the sales outlet where you purchased the device.
4. If you think the measurement is abnormal or if measurement makes you feel unwell,
discontinue use and consult your physician.
5. Blood pressure measurement may not be possible for anyone with a weak pulse or
arrhythmia.
6. Repeated blood pressure measurement may cause problems such as congestion or
swelling in some people.
7. Frequently repeated blood pressure measurements will not give accurate results.
Allow an interval of about 3 minutes between measurements.
8. If you suffer from a severe problem with blood circulation in your arms, consult your
physician before using the device. Failure to do so could be hazardous to your health.
9. Measurement may not be possible for anyone with insufficient blood flow to the area
where measurements will be taken or who suffers from a frequent irregular heartbeat.
Consult your physician for advice on whether to use the device.
10. DO NOT wrap the cuff around an elbow. DO NOT wrap over a wound.
11. DO NOT wrap the arm cuff around an elbow in which a drip (intravenous infusion) is
inserted or which is being used for blood transfusion as part of medical treatment.
Doing so could result in an injury or a serious accident.
12. DO NOT wrap the cuff on the arm on the side of a mastectomy.
13. DO NOT use the device in the vicinity of flammable gases such as those used for
anesthesia. Doing so could ignite the gases and cause an explosion.
14. DO NOT use the device in enriched oxygen environments such as a hospital’s
hyperbaric chamber or oxygen tent. Doing so could ignite the oxygen and cause a
fire.
15. DO NOT use mobile phones near the device as this could result in a malfunction.
DO NOT use the device with hf surgical equipment.
16. If you use a cardiac pacemaker, consult your physician before using the device.
17. Be sure to use this device only for measuring blood pressure. DO NOT use it for any
other purpose.
18. DO NOT use this device on infants, pregnant women or pre-eclamptic patients.
19. DO NOT use this device for patients that transport outside a healthcare facility.
20. Blood pressure measurement may not be possible for anyone with common
arrhythmias such as arterial or ventricular premature beats or arterial fibrillation.
21. Be careful to strangulation due to cables and hoses, particularly due to excessive length. It will not cause any potential alergic reaction or contact injury. If you are allergic to dacron or plastic, please don’t use this device
Precautions for Maintenance:
1. DO NOT store the blood pressure monitor in locations exposed to direct sunlight, high
temperatures (over 60°C), low temperatures (below -20°C), high relative humidity
(over 85%) or excessive amounts of dust.
2. DO NOT drop the blood pressure monitor or subject it to other shocks or vibration.
3. Remove the batteries if the device will be left unused for a long period.
4. DO NOT attempt to disassemble the device. User can open battery cover for new
battery installation.
DO NOT bend the cuff or air hose excessively.
5. NEVER clean the blood pressure monitor with thinners or benzene, as they may
damage it.
6. DO NOT hard rub when clean the cuff. Take care not to get water into the air hose.
7. DO keep the device out of reach of children, pets and insects.
III. Name of Each Part
Figure 1 - Appearance
MEMORY” Button /Clock Setting
Memory Button /Measured Result recall/ Clock Number
Adjusting
“ON/OFF” Button
LCD Display
Systolic Indicator
Diastolic Indicator
Pulse Indicator
Figure 2 – Display of LCD
Note for LCD display:
(1) Date: Month - Day
(2) Time: Hour – Minute
(3) Systolic Blood Pressure (unit: mmHg)
(4) Diastolic Blood Pressure (unit: mmHg)
(5) Pulse Rate(unit: beat/minute)
(6) WHO Blood Pressure Classification Indicator
(7) Inflation / Deflation Indicator
(8) Blood Pressure Measurement Unit
(9) Battery Symbol
(10) Irregular heartbeat Indicator
(11) Memory Record Number
* Back light display function is optional.
IV. Measure Procedure
Battery Loading
Remove the battery compartment cover by gently pushing down on arrow and sliding
cover forward.
Place batteries with positive “+” and negative “-“ terminals into compartment and make
sure they match the indicated terminals in the compartment.
Loading...
+ 14 hidden pages