FC LIGHTING FCW5806 Installation Instructions Manual

FCW5806 - INSTALLATION INSTRUCTIONS
CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.
GENERAL:
1. Before starting the installation, make sure all electricity has been turned off and electrical breaker has been locked out and tagged out.
corporate
t 800.900.1730 f 630.889.8106
3609 Swenson Ave. St. Charles, IL 60174
2. To ensure the success of the installation, be sure to read these instructions and review the diagrams thoroughly before beginning.
3. All electrical connections must be in accordance with local codes, ordinances, or the National Electrical Code.
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur.
INSTALLATION:
A) Standard Canopy installation Fig. A
1) Remove (3) Set Screws from base of xture to remove base mounting
plate from the Canopy Housing
2) Fasten Mounting Plate to desired surface.
3) Refasten Mounting Canopy to secured Mounting Plate.
4) Adjust xture tilt and swivel to desired light angle.
B) Integral Ballast Box (IBB) Canopy installation Fig. B
1) Fixture comes assembled and only needs to be fastened to mounting
surface.
2) Use 4 holes at the base of the Mounting Plate to fasten xture to
desired mounting surface.
3) Adjust xture tilt and swivel to desired light angle.
Power Cord
5.04 in
A
Fixture
Mounting Canopy
Set Screws
Mounting Plate
[ 2.5 in ]
B
IBB
Integral Ballast Box Mounting Canopy
[ 6.5 in ]
[ ø 6.25 in ]
[ 10.0 in ]
[ ø 6.0 in ]
Adjust Tilt
Adjust Swivel
NOTE: Installing xtures as shown here requires no silicone sealant.
Mounting Plate
Fig. A, xture power cord does not pass through Mounting Canopy. Fig. B, Mounting Canopy and Mounting Plate are rubber gasket sealed.
CONFIDENTIAL
THIS DOCUMENT IS THE PROPRIETARY PROPERTY OF FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED. ©2013 FC LIGHTING, INC.
7.63 in
FCW5806 (Bollard Mount) - INSTALLATION INSTRUCTIONS
CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.
GENERAL:
1. Before starting the installation, make sure all electricity has been turned off and electrical breaker has been locked out and tagged out.
2. To ensure the success of the installation, be sure to read these instructions and review the diagrams thoroughly before beginning.
3. All electrical connections must be in accordance with local codes, ordinances, or the National Electrical Code.
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur.
corporate
t 800.900.1730 f 630.889.8106
3609 Swenson Ave. St. Charles, IL 60174
Fixture
INSTALLATION:
1) Contact local authorities regarding dig location prior to digging.
2) Dig oversized hole to accommodate post and backlling.
3) Pass wiring in through .875” hole on side of bollard and up through the
Bollard Top Plate and Mounting Plate.
4) Lower Bollard post in ground, level post and backll.
NOTE: Regardless of material used to backll hole, continue to check and
level the post during this process.
5) Complete wiring to the xture.
6) Ensure that the Mounting Plate is secured to the Bollard Top Plate.
7) Fasten Mounting Canopy with Fixture to Mounting Plate using Set
Screws provided.
IMPORTANT: Installer must use a bead of silicone caulk to seal around the entire edge of the xture where Mounting Plate meets Mounting Canopy and Bollard Top Plate.
Power Cord
Mounting Canopy
Set Screws
Mounting Plate
Bollard Top Plate
Bollard
24 in (above ground)
60 in
36 in (below ground)
.875 in Hole
CONFIDENTIAL
THIS DOCUMENT IS THE PROPRIETARY PROPERTY OF FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED. ©2013 FC LIGHTING, INC.