XL4600DL
NOTE: Owners manual not to be
removed by anyone but the occupant.
AN FBX COMPANY 100
Owners Manual
Engineers
(516) 582-6161 = (800) MS-5430
Road, Hauppauge, New York 11788
NEW YORK
OUT OF STATE
12524 6190
01990, FBX
1 l ’ KEYPAD LAYOUT
The keypad is the arming station for the STAR XL46OODL. Three different versions
are available, a metal plate flush mounted version (XL4600RM), a plastic cased
surface mount version, and an LCD (liquid crystal display) version containing a two line !
readout. The keypads have the following appearance and contain the following Hems;
XL 4600 RP
Keypad
i
2-
I3
5/
\.
,
‘
L
-
-
-
1) ZONE STATUS INDICATORS - displays the current zone status as follows;
ALARM Fast blinking.
BYPASS
Slow blinking low intensity.
TROUBLE Slow pulse
NOT READY Solid ON
2) ARM/DISARM INDICATOR -Shows whether the system is currently armed (ON) or
disarmed (OFF).
3) STAY- shows the system has been armed with the interior zones bypassed.
4) INSTANT - shows whether the system has been ARMED with all delay zones
instant.
5) AC/LOW BATTERY - shows whether the system is running on AC (ON) or backup
battery (OFF).
6) READY Indicates whether the system is ready for arming.
7) NUMERICAL KEYPAD operates in a similar manner to a calculator or telephone
with the digits 0 - 9 and l # clearly marked.
6) DISPLAY AREA- This section of the LCD keypad displays the current system status
in this two line by sixteen character display. The second line of this display can be
programmed by your installer to contain customized descriptors for the areas of
protection within your location.
Throughout this users manual the following conventions are used to display the
keystrokes required to perform the functions.
BYPASS Key labeled BYPASS on keypad.
INSTANT Key labeled INSTANT on keypad.
STAY Key labeled STAY on keypad.
CODE Key labeled CODE on keypad
[USER]
Four digit user code.
2. ARMING THE SYSTEM
ARMING the system will activate all portions of your Security System. Arming can
only be performed if all zones are READY. For example, if a protected door is open the
system cannot be armed.
SYSTEM READY
The system is ready to be armed if the READY indicator light ON.
On LCD keypads the following display will appear:
If the system is ready, ARMING can be performed as follows;
ARMNG PROCEDURE:
1. Enter your four digit user code into the keypad:
IUSEW
The ARMED indicator light will now be lit and if you are leaving the home you may
exit through a door designated by your installer as an exit/entry zone for a fixed time
period known as the exit delay.
The entry exit times for your system are as follows;
ENTRY:
LCD keypads will display the following message;
NOTE: The system can be armed without the backup battery being connected.
BYSTEYREADY ‘.
seconds- EXIT:
f3my
seconds
‘C
SYSTEM NOT READY
If the system is not ready to be armed the READY indicator will be OFF. On LED
based keypads the zone indicator lights will display the zones which are currently not
ready. The condition of each zone indicator reflects what the status of each zone as
follows;
ALARM
BYPASS
TROUBLE
NOT READY
The LCD keypad a display will appear indicating that the system Is not ready followed
by displays showing the zone number and description of the zone or zones which are
not ready. For example:
Fast blinking.
Slow blinking low intensity.
Slow pulse
Solid ON
/
PYSTEMNOTREADYl
In this example, the front door is not ready (Zone 1).
In order to make the system ready determine which zones are not ready by observing
the zone indicator lights, or the display section of the LCD keypad. From the zone
number you can find out which area of protection is not ready.
For example, assume the zone 1 is not ready. Typically this might mean thp?
protected door or window is open.
>>
Once the problems with each zone has been resolved the READY light will
appear and the system can be armed.
To ARM the system when the system is NOT READY one of the following actions
are necessary;
\ ,