1 l ’ KEYPAD LAYOUT
The keypad is the arming station for the STAR XL46OODL. Three different versions are available, a metal plate flush mounted version (XL4600RM), a plastic cased surface mount version, and an LCD (liquid crystal display) version containing a two line ! readout. The keypads have the following appearance and contain the following Hems;
XL 4600 RP
Keypad
i
2-
I3
5/
\.
, ‘ L
-
-
-
1) ZONE STATUS INDICATORS - displays the current zone status as follows; ALARM Fast blinking.
BYPASS
Slow blinking low intensity. TROUBLE Slow pulse NOT READY Solid ON
2) ARM/DISARM INDICATOR -Shows whether the system is currently armed (ON) or disarmed (OFF).
3) STAY- shows the system has been armed with the interior zones bypassed.
4) INSTANT - shows whether the system has been ARMED with all delay zones instant.
5) AC/LOW BATTERY - shows whether the system is running on AC (ON) or backup battery (OFF).
6) READY Indicates whether the system is ready for arming.
7) NUMERICAL KEYPAD operates in a similar manner to a calculator or telephone with the digits 0 - 9 and l # clearly marked.
6) DISPLAY AREA- This section of the LCD keypad displays the current system status in this two line by sixteen character display. The second line of this display can be programmed by your installer to contain customized descriptors for the areas of protection within your location.
Throughout this users manual the following conventions are used to display the
keystrokes required to perform the functions.
BYPASS Key labeled BYPASS on keypad. INSTANT Key labeled INSTANT on keypad. STAY Key labeled STAY on keypad. CODE Key labeled CODE on keypad [USER]
Four digit user code.
2. ARMING THE SYSTEM
ARMING the system will activate all portions of your Security System. Arming can only be performed if all zones are READY. For example, if a protected door is open the system cannot be armed.
SYSTEM READY
The system is ready to be armed if the READY indicator light ON. On LCD keypads the following display will appear:
If the system is ready, ARMING can be performed as follows; ARMNG PROCEDURE:
1. Enter your four digit user code into the keypad: IUSEW
The ARMED indicator light will now be lit and if you are leaving the home you may exit through a door designated by your installer as an exit/entry zone for a fixed time period known as the exit delay. The entry exit times for your system are as follows;
ENTRY:
LCD keypads will display the following message;
NOTE: The system can be armed without the backup battery being connected.
BYSTEYREADY ‘.
seconds- EXIT:
f3my
seconds
‘C
SYSTEM NOT READY
If the system is not ready to be armed the READY indicator will be OFF. On LED based keypads the zone indicator lights will display the zones which are currently not ready. The condition of each zone indicator reflects what the status of each zone as follows;
ALARM BYPASS TROUBLE NOT READY
The LCD keypad a display will appear indicating that the system Is not ready followed by displays showing the zone number and description of the zone or zones which are not ready. For example:
Fast blinking. Slow blinking low intensity. Slow pulse Solid ON
/
PYSTEMNOTREADYl
In this example, the front door is not ready (Zone 1).
In order to make the system ready determine which zones are not ready by observing the zone indicator lights, or the display section of the LCD keypad. From the zone number you can find out which area of protection is not ready.
For example, assume the zone 1 is not ready. Typically this might mean thp?
protected door or window is open.
>>
Once the problems with each zone has been resolved the READY light will
appear and the system can be armed.
To ARM the system when the system is NOT READY one of the following actions
are necessary;
\ ,