FBII Omni-KP, Omni-LCD Installation And Setup Manual

)
INSTALLATION AND SETUP GUIDE
Keypad Features
Backlit Display YES YES Built-in Sounder Piezo Speaker
The Omni®-KP and Omni®-LCD are addressable Remote Keypads designed for use with FBII Omni Series control panels. Addresses are set via the keypad keys.
The keys on the keypads are continuously backlit for convenience.
KEYPAD DISPLAYS AND LEDS
The keypads have the following display features:
Model
Fixed Word
Display
2-line
Alpha
Display
Omni-KP X X Omni-LCD X X
2-digit
Zone
Identifier
Descriptors
The following table shows the LEDs and their functions:
LED Function
Red Lights when the system is armed in any mode Green Lights when the system is "ready" to be armed.
Fixed-Word
Custom
Zone
Omni-KP
REMOTE KEYPADS
Omni®-KP & Omni®-LC
ARMED
READY
Omni-KP w/ Protective Cover Removed
Omni-LCD is not available in the U.S.
(
Omni-LCD
2-Line Alpha
STAY
BYPASS
INSTANT
CODE
2
1 4 7
3
5
6
8
9
0
#
K3590-FBIIV1 6/01
omni-KP-001-V0
WIRING AND INSTALLATION
The keypads can be surface-mounted directly to a drywall, or to a single- or double-gang electrical box.
1.
Remove the case back
by sliding the blade of a screwdriver-between the tab and the case back on each side of the keypad as shown in lower diagram at right.
2.
Route wiring from the control panel
through the
opening in the case back.
3.
Mount the case back
to a wall or electrical box.
For wall mounting of the Omni-KP/LCD in the FR, NL and IT versions, secure the ca se ba ck to the wal l, being es pe ci ally careful to secure the parti ally knocked-out tam per switch plunger with its own screw. This assures that separation of the keypad from its mounting will cause the tamper switch to activate. Any attempt to pry the keypad open will also activate the tamper switch in these versions.
4.
Wire directly from the keypad’s terminal block
to the terminal block on the control board. Wire functions are marked next to terminals. Labels are as follows: DI Data In to Control Panel, - Ground, + Aux. Power Plus, DO Data Out of Control Panel. See table on next page.
5.
Reattach the keypad
to its case back.
ARMED
READY
STAY
BYPASS
INSTANT
CODE
2
1 4 7
3
5
6
8
9
0
#
omni-LCD-001-V0
Omni-LCD w/ Protective Cover Removed
TO SEPARATE TOP COVER
INSERT SCREWDRIVER
AND PUSH HERE
ARMED
READY
omni-LCD-002-V0
Separating Case Back From Top Cover
TURNING BACKLIGHT TIMER ON and OFF
Omni-KP
Press and hold down the time for about three seconds. Press the [1] key that toggles a zero or one in the display: 0 = Backlight always on 1 = Backlight on an approximate 120-second timeout
Press [] key to exit this Backlight menu.
INSTANT
and
keys at the same
CODE
Omni-LCD
Press and hold down the time for about three seconds.
Press the [1] key to toggle the display between: 0 = Backlight always on and 1 = Backlight on an approximate 120-second timeout.
Press [] key to exit this Backlight menu.
INSTANT
and
keys at the same
CODE
SETTING THE KEYPAD ADDRESS
The keypad can be set for an address of 1-8. The keypad's default address is 8.
To change the keypad's address, do the following:
1. Enter Address mode: Power up the keypad. Within 60 seconds of powerup, press and hold down th e the same time for 3 seconds. If unable to enter Address mode (address is not flashi ng), power down, then power up and tr y again.)
The current keypad address will be displayed. Select keys 1-8 to
change the keypad address. If 10 seconds have passed with no key entry, the keypad automatically exits Address mode.
2. If the panel does not send a valid command to the keypad, the display will remain blank.
3. Exit Address mode: Press [] key to save the displayed address and exit Address mode.
STAY
and
CODE
keys at
VIEWING THE KEYPAD ADDRESS
Press and hold down the for about 3 seconds. The current address is displayed. No key entry is allowed. Press exit viewing mode.
[]
key to exit or wait 10 seconds to automatically
STAY
and
keys at the same time
CODE
TURNING THE SOUNDER ON/OFF
Chime will not operate if keypad sounder is disabled (off).
NOTE:
USING THE SOUNDER MENU (Omni-LCD only)
Press the BYPASS and CODE keys at the same time and hold down for two seconds. This accesses the Sounder Menu.
1. Press the [1] key to toggle through the following four modes and stop at desired mode. On - Normal Sounder Keys (all sounds on) Key - Only Key Clicks Fire - Only Fire Sounder (temporal sounder – not supported by all panels) Off - No Sounds at all
2. Press the [2] key to toggle through the sounder volume
choices (high or low appears on the display).
3. Press the [3] key to adjust the sound of the key acknowledge
(Ack H or L appears on the display).
4. Press the [✱] key to exit the Sounder Menu.
SPECIFICATIONS
Physical:
Omni-KP: 5"H x 6-1/2"W x 1-5/16"D Omni-LCD: 5-5/16"H x 7-1/2"W x 1-5/16"D
Wiring (all Keypads):
Keypad Terminal Control Panel Terminal
DO or
+
x
GRN
RED – BLK DI or z
YEL
Displays:
Omni-KP: Fixed-Word LCD (backlit). Omni-LCD: 2 x 16 alpha-numeric supertwist LCD, backlit.
Sounder:
Omni-KP: Piezo-electric (fire alarm is loud, pulsing single
tone; (all Keypads) burglary alarm is loud,
Omni-LCD: Speaker.
continuous, dual tone).
Current:
Omni-KP: In alarm ................................70mA
Standby (Backlight off/on).....28mA/45mA
Omni-LCD: In alarm ................................130mA
Standby (Backlight off/on).....35mA/81mA
Omni-KP:
Press the hold for two seconds until you hear a beep. Press any key to toggle sounder on and off. Press
BYPASS
[] to exit and save this setting.
and
keys at the same time and
CODE
0=Sounder off, 1=Sounder on