Quick Reference
TO ARM THE SYSTEM
1. Check to make sure the system is ready. (Green READY light is lit).
2. Enter your 4-digit (or 6-digit) user code.
The ARMED light will light.
3. Exit through a door designated by your installer as an exit/entry door.
NOTE: If you DO NOT EXIT during the exit time and your system installer has
programmed your system for Auto-Stay, the system will arm in the Auto-Stay
mode.
TO DISARM THE SYSTEM
1. Enter through a door designated by your installer as an exit/entry door.
2. Enter your 4-digit (or 6-digit) user code.
3. The system ARMED light will go out.
TO ARM THE SYSTEM AND STAY INSIDE
1. Check to make sure the system is ready (Green READY light is lit).
2. Press
3. Enter your 4-digit (or 6-digit) user code.
The ARMED light and the STAY light will both light.
REMEMBER: Unless the Quick Exit feature is enabled, you must disarm the
system if you want to open a premises entry/exit door after the exit time has
passed.
TO ARM THE SYSTEM IN INSTANT MODE, AND STAY INSIDE
1. Check to make sure the system is ready (Green READY light is lit).
2. Press
3. Press
Enter your 4-digit (or 6-digit) user code.
4.
The ARMED light, the INSTANT light, and the STAY light will all be on.
TO RESET SMOKE DETECTOR
1. Enter your 4-digit (or 6-digit) user code twice.
STAY
INSTANT
STAY
.
.
.
- 4 -
Page 5
Quick Reference (Cont’d)
The following table lists the “Quick Commands” available with this control.
Key Description Keypads Comments
#
1
#
2
BYPASS
nn (zone no.)
#
3
#
4
#
50
#
51
#
52
#
53
#
54
#
55
#
57
#
58
#
6
#
8
#
9
Quick Arm
Force Arm
zones
Quick Bypass
Set Time and Date
Zone Directory
Quick Help
Show Time and Date
Show Auto Arm Time
User Event Log View
Set Auto Arm Time
Display Firmware Version
Door Strike
Change/View Pager Number
Display/Toggle Chime Mode
User Page Toggle
User On-line
– if system is ready
– bypasses faulted
* 2-line alpha display
All keypads Allows you to arm the system without
requiring your user code . U se r code is
always needed to disarm the system.
All keypads Allows you to arm the system even if
some zones are faulted. These zones will
be automatically bypassed and will be
unprotected.
All keypads If not enabled, re quires user code with
authority 1, 2, or 3.
All keypads May require user code.
LCD* only Lists each zone with its descriptors. Mode
terminates after last enabled zone.
LCD* only Provides a listing of all quick commands
available in the system.
LCD* only May also require code.
LCD* only May also require code.
LCD* only Also needs user code with authority level
1 or 2.
All keypads May also require co de.
LCD* only Displays panel’s revision.
All keypads Activate doorstrike or trigger. May
require certain user code.
All keypads For keypad, only LCD* shows phone
number. May also require code.
All keypads LCD* displays current state first, then
offers to toggle. All others just toggle the
state.
All keypads Toggles if users should send page for
Open/Close.
All keypads Connects to downloader while on line,
disconnects home phone.
- 5 -
Page 6
Introduction
Congratulations on your decision to protect your home or business with the
OMNI security system. You have chosen a reliable, state-of-the-art security
system that is remarkably easy to operate. Your system has been professionally
installed by your local Security Company, whose representative can explain the
specifics of your system.
The keypad is the input and display device for your security system. Your
Security Company representative will suggest the model most appropriate for
your premises and your needs. There are three types of keypads that can be used
with this system:
LCD keypad (alpha display), fixed-word keypad (2-digit display), LED keypad.
Since your system may use any of these keypads, the displays of all keypads are
described in this manual.
The OMNI-400 and OMNI-600 are listed by Underwriters Laboratories for
Household Fire and Burglary applications.
Throughout this manual, the following conventions are used to represent the
keystrokes required to perform the following functions.
- 6 -
STAY
BYPASS Press button labeled BYPASS.
INSTANT Press button labeled INSTANT.
CODE Press button labeled CODE.
Please keep your manual in a convenient location so you can refer to it
if needed.
Press button labeled STAY.
Enter 4-digit (or 6-digit) user code.
Page 7
ZONE DESCRIPTIONS
In the following table, enter a description of the area of protection for each
zone.
Example: Zone 1 Windows on north side of building
Zone 4 Main entrance to building
Zone Description
1
2
3
4
5
6
7
8
9*
10*
11*
12*
System Reference
* Zones 09 through 12 are not used in the OMNI-400 or OMNI-
400EU. These zones apply to the OMNI-600 and OMNI-600EU
ONLY.
Entry time ________ Door __________ Exit time ________
Entry time ________ Door __________
Exit time is the same for all designated entry/exit doors.
MONITORING STATION INFORMATION
Account #
Telephone #
- 7 -
Page 8
System Reference (Cont’d)
SEND HELP ALERT
All keypads are equipped with emergency-pair keys. In order to
activate the alert, both keys must be pressed at the same time. The
type of keypad you have installed dictates which keys you press. Your
installer will show yo u how to activate th ese eme rgency ke ys. The emerg ency
keys used for all keypads are shown below.
The following SEND-HELP ALERT is programmed into my system:
KEYS DESCRIPTION
[#] & [✱]
[7] & [9]
[1] & [3]
PAGER ALERT
If programmed, the emergency may also be used to send an alert message to
a pager. Ask your installer if this was done.
USER CODE ASSIGNMENTS
In the following table, enter the names of the individuals assigned to each
user number.
on installer programming. Ask your installer what type of user codes (4- or 6-
6-digit
digit) are being used in your system. When performing system functions, you
must use the appropriate 4 or 6-digit user codes.
- 8 -
User codes can be either 4 digits or 6 digits, depending
Page 9
IS THE SYSTEM READY?
You can arm and disarm the burglar portion of your security system. Before
you can arm the system, it must be “ready.” If you have a protected door
open, or someone is mo ving in view of a motion detecto r, the system will not
display the “READY” message.
The system is ready if the READY light and the display show:
LCD Keypad:
SYSTEM READY
NOTE: If programmed by your installer, you may arm the system if a delay
or interior zone is faulted. However, faulted zones must be restored before
your exit time expires or an alarm or zone bypass will result. Ask your
installer if your system has this feature and if so, if it causes an alarm or
zone bypass.
TO ARM THE SYSTEM AND LEAVE
Enter your user code.
The System ARMED light will go on and the display will show:
LCD Keypad:
ON: AWAY 120s
NOTE: The number 120 shown above for th e LCD and Fixed-Wo rd keypads
indicate a counter that is updated every second and displays the amount of
time remaining to exit without sounding an alarm.
Exit through a door desig nated by your installer as an exit/entry door. Yo u
must leave within the ex it time programmed by your installer. Refer to the
reference sheet for the time th at has been set for your system.
Arming the System
Fixed-Word Keypad:
“Ready” LED lit
Fixed-Word Keypad:
“Armed” LED lit
120
LED Keypad:
“Ready” LED lit
LED Keypad:
“Arm” LED lit
This system can be programmed by the installer for the AUTOSTAY feature,
which automatica lly by p a sse s inte r io r zo n e s if y o u ar m th e syste m and d o n o t
exit through a delay zone during exit time.
- 9 -
Page 10
Arming the System (Cont’d)
WHEN THE SYSTEM IS NOT READY
If the system is not ready to be armed, the READY light will be off and the
display will show which z on e or zones are not re ady. Th e follo wing cond itions
will be indicated by the zone lights (LED keypad) or described on the display:
Fast Blink .................................Alarm or tamper condition
Slow Blink/Low Intensity .....Bypass
Slow Pulse ................................ Trouble or low battery
Solid On .................................... Zone faulted
Example: If the READY light is not lit and the Zo ne 1 lig ht is solid on, an
alarm sensor on Zone 1 is faulted. This might mean that a door is open or
someone is walking in view of a motion sensor. Check all sensors on Zone 1
and resolve the problem. In this example, the display shows the following:
NOT READY
When all sensors are resto red, the READY light will come on and the zone
light will go out.
Determine which zone or zones are not ready, resolve the problem, and arm
the system normally. If the problem cannot be resolved, you may bypass the
zone that is not ready. B ypassing should only be done if the problem on the
zone cannot be resolved, OR if you intentionally wish to leave the zone
disarmed. For example, you would leave the zone disarmed if you plan to
keep the window open for ventilation. Zonesthat are bypassed are not protected when the system is armed. See To Bypass A Zone on the
following page for a description of the procedure.
and
NOT RDY ZN 1
FRONT DOOR
- 10 -
Page 11
TO ARM THE SYSTEM AND STAY INSIDE
To arm the perimeter portion o f your burglar alarm and move around free ly
inside the premises, use the STAY mode.
Check to make sure the system is ready. When it is ready, press:
Arming the System (Cont’d)
STAY
followed by your user code.
When the system has been armed successfully, the ARMED indicator lights
and the following will be displayed:
LCD Keypad:
ON: STAY
REMEMBER:
Fixed-Word Keypad:
STAY
You must disarm the system or press [STAY] to initiate the
LED Keypad:
“Arm” and “Stay” LEDs
lit
“quick exit” if you want to open the door or leave the premises after the exit
time has expired. Quick Exit restarts the exit time without disarming the
system.
TO ARM THE SYSTEM IN INSTANT MODE AND STAY INSIDE
In INSTANT STAY mode, the perimeter portion of your burglar alarm
system is armed but the time delays are eliminated from your normal
entry/exit door(s). All interior protection is disarmed, so you are free to move
around inside.
Check to make sure the system is READY. When it is ready, press:
INSTANT
STAY
When the system has been armed successfully, the ARMED light, the
INSTANT light, and the STAY light will all be on, and th e following will be
displayed:
LCD Keypad:
ON: STAY / INS
followed by
followed by your user code.
Fixed-Word Keypad:
STAY
INSTANT
LED Keypad:
“Armed,” “Stay,” and
“Instant” LEDs lit
- 11 -
Page 12
Arming the System (Cont’d)
TO ARM THE SYSTEM IN INSTANT MODE
In INSTANT mode, all alarm sensors, including doors that no rmally have a
delay to allow yo u to disarm the system, will report an alarm im mediately if
activated. Check to make sure the system is ready. When it is ready, press:
INSTANT
When the system has been armed successfully, the ARMED light and the
INSTANT light will be on, and the following will be displayed:
LCD Keypad:
ON: INSTANT
TO BYPASS A ZONE
The Bypass function excludes a zone of protection from the security system
until it is unbypassed (either by using the unbypass procedure or when you
disarm the system). Bypassing can only be done while the system is
disarmed.
NOTE: 24-hour zones m ay be bypassed, but can only be unbypassed if the
zone is not faulted (condition has been cleared).
Press the BYPASS button. Then enter your user code and the zone number
(01–08; OMNI-400 and 400EU or 01–12; OMNI-600 or 600EU) to be
bypassed, as follows:
BYPASS
†
If the Quick Bypass feature has been enabled by the installer, do not enter
the user code when bypassing zones.
NOTE:
After the bypass command has been accepted, the keypad sounds one long
beep, and the following is displayed:
Bypassed zones are NOT protected when the system is turned on.
LCD Keypad:
BYPASSED: ZN 01
FRONT DOOR
followed by your user code.
Fixed-Word Keypad:
INSTANT
followed by your user code
Fixed-Word Keypad:
BYPASS
zone number displayed
LED Keypad:
“Arm” and “Instant”
LEDs lit
†
+
LED Keypad:
ZONE NO.
Zone LEDs of the
zone(s) bypassed slowly
blink
- 12 -
Page 13
Arming the System (Cont’d)
To Bypass multiple zones, within 10 seconds of the BYPASS + User Code +
Zone No. entry, enter
BYPASS
This command can be repeated for each zone to be bypassed.
TO UNBYPASS A ZONE
Pressing the BYPASS bu tton returns a bypassed zone to normal operation.
To unbypass a zone, the system must be disarmed (also note that 24-hour
zones cannot be unbypassed if they are faulted). To unbypass a zone(s),
repeat the bypass function as follows:
BYPASS followed by your user code
After unbypassing, the zone display will show the state of the zones.
†
If the Quick Bypass feature has been enabled by the installer, do not enter
the user code when unbypassing zones.
ZONE NO.
+
†
+
ZONE NO.
- 13 -
Page 14
Disarming the System
When you disarm the system, you disarm only the burglar portion of your
system; any smoke or heat detectors and panic keys will remain armed. You
must enter through a designated entry door and disarm the system within
the time allowed. You can have different amounts of time for different entry
points. See your system reference sheet for the times established for your
system.
To disarm your system:
Enter your user code.
If no alarms have taken place, the ARMED light will go off, or the display
shows:
LCD Keypad:
SYSTEM READY
If alarms occurred when the system was armed or if a trouble condition
exists, the display shows:
LCD Keypad:
ALM MEM ZN1
Fire alarms will generate a pulsing sound. Burglary alarms will sound a
steady tone at the keypad(s) that lasts until the alarm is cleared or until the
amount of time (alarm timeout) set by your syste m installer has passed. If
the amount of time set by your installer has passed and the alarm has no t
been cleared, the audible alert switches to a pulsing sound that remains
active until the alarm is cleared.
IMPORTANT: If an intrusion has taken place while you were away, do not
enter until the location has been checked. Call for help from a neighbor's
house and wait there for the police.
To clear the display of alarm or trouble conditions and silence the audible
alert:
Enter your user code again.
Fixed-Word Keypad:
“Ready” LED lit
Fixed-Word Keypad:
“Arm” LED lit
“Ready” LED blinks
LED Keypad:
“Ready” LED lit
LED Keypad, zone
LEDs:
Fast Blink = alarm or tamper
Slow Blink = bypass
Slow Pulse = trouble, or low
battery
Solid On = zone faulted
- 14 -
Page 15
TO ADD OR CHANGE A USER CODE
Users can be added or changed directly at the keypad. Your system can have
up to 15 different user codes, with each assigned to one of four authority
levels. The authority level determines the functions that users can perform.
In addition, your system can be set up for 4-digit or 6-digit user codes. Ask
your installer which type of user codes is used in your system.
To add or change a user code, press the following:
CODE [1–4]
e.g., CODE 1 2 3 4 0 8 5 6 7 8 3
Authority Levels
Level Functions Allowed
1 Primary Master: can view log and set time, assign other user codes, all system
functions
2 Secondary Master: same as primary master except cannot change the primary
master’s code
3 User: can arm and disarm only
4 Limited user: same as level 3, except can disarm the system only if it was armed
by another user with level 4 authority (cannot disarm if armed by user of higher
authority level)
Master User Code (01–15) N ew User Code Level
User Codes
User ID Auth.
TO DELETE A USER CODE
To delete a user, press the [CODE] button followed by the 4-digit master user
code. Enter the user number, then press the [#] key to delete. For example, to
delete user 3, do the following:
CODE 0 3
NOTE:
User No. 1, the master user, cannot be deleted but it can be changed
using the ADD OR CHANGE A USER CODE procedure.
Master User Code User ID # Key To Delete
[#]
- 15 -
Page 16
Miscellaneous Commands
TO SEND HELP ALERTS
Your system can be prog rammed fo r 3 separa te key pad Se nd Help alert s that
would send an emergency signal to your central station or trouble signal to a
pager. See the System Reference sheet to see which have been programmed
for your system.
DURESS
Your system can be programmed to send an emergency signal to the central
station if you are forced to enter the premises under threat. If you choose to
include this feature, assign a code to user 15, which is dedicated to this
function, if programmed. Use this code only under a duress circumstance.
QUICK ARMING
If programmed by your installe r, Quick Arming allo ws you to arm th e syste m
in the AWAY mode without entering a user code.
Press
NOTE: Disarming your system always requires a valid user code.
NOTE: This system can be programmed by the installer for the AUTOSTAY
feature, which automatically bypasses interior zones if you arm the system
and do not exit through a delay zone during exit time.
#
then
1
.
QUICK FORCED ARMING
If programmed by your installer, Qu ick Forced Armin g allows you to arm the
system in the AWAY mode by automatically bypa ssing all zones that are not
ready.
Press
NOTE:
UL NOTE:
NOTE:
feature, which automatically bypasses interior zones if you arm the system
and do not exit through a delay zone during exit time.
then
#
A valid user code is still required to disarm the system.
This feature is disabled on UL installations.
This system can be programmed by the installer for the AUTOSTAY
QUICK BYPASS
If you have Quick Bypass programmed for your system, you can bypass zones
without entering your user code. The Quick Bypass procedure is:
BYPASS
- 16 -
plus 2-digit Zone No. (e.g., 01 for zone 1)
2
.
Page 17
NOTE: Bypassed zones are not protected when the system is armed. After
the bypass command has been accepted, the keypad sounds one long beep.
The zone light of the bypassed zone(s) slowly blinks, or the display shows:
LCD Keypad:
BYPASSED: ZN1
NOTE: Temporary users (i.e., babysitters, housekeepers, etc.) should not be
shown the Bypass procedure.
QUICK EXIT
Quick Exit restarts exit delay time if the system is already armed. This
allows someone to leave after the system has been armed, without having to
disarm the system first. To restart the exit delay time, press:
TO TURN CHIME ON/OFF
Chime is an optional feature that causes the keypad to beep when selected
doors are opened while the burglary protection is disarmed.
Only your installer can program a zone for the Chime feature, but once
programmed, you can turn Chime on or off to meet your daily needs.
To turn Chime on or off, press:
Miscellaneous Commands (Cont’d)
Fixed-Word Keypad:
Bypass LED lit
STAY
then
#
[6]
LED Keypad:
Zone light of the
bypassed zone(s) will
slowly blink
TO VIEW QUICK COMMAND LIST (LCD Keypads Only)
To view a display of available quick commands, press:
To step through the available quick commands, press # .
To exit the quick command list, press ✳ .
TO SET AUTO-ARM TIME
Auto-Arm Time lets you set the time your system automatically arms.
To set the Auto Arm Time, press:
[5] [4] [user code*] [hour 00–23] [minute 00–59]
#
*The user code is not required if so programmed by installer.
The keypad will prompt you for the required entries.
then [5] [0].
#
- 17 -
Page 18
Miscellaneous Commands (Cont’d)
TO VIEW AUTO-ARM TIME (LCD Keypads Only)
To view the auto-arm time, press:
authority level 1 or 2.
AUTOARM TIME:
05:00PM
*The user code is not required if so programmed by installer.
DOOR STRIKE
To activate door strikes, press:
If programmed, certain user cod es (10–14) can also be used to open a door.
See your installer for door numbers.
TO VIEW TIME (LCD Keypads Only)
To view the system time, press:
follows:
Jan 27, 2001
08:15A
TO SET TIME
To set the time, press:
programmed by installer), then follow the prompts (on LCD keypads only)
and enter the hour, minute, month, day, and year. All entries are 2-digit
entries. Additionally, if your system installer has set your system to use an
internal crystal real-time clock, you will be promted to enter a crystal
adjustment. If your clock has been keeping the proper time, respond to the
crystal adjustment prompt by pressing [1] followed by [0][0] when the system
prompts you for an adjustment value. If the clock has not been keeping time
correctly, when the crystal adjustment prompt is displayed, proceed as
follows:
1. Enter 0 (Adjust up - Clock slow) or 1 (Adjust down - Clock fast). The
adjustment value prompt is displ ayed.
2. Determine how far off the clock is (in seconds) from the correct time.
3. Determine the number of days since the last time the clock was set.
4. Divide the number of seconds that the clock is off by the number of days
since the last time the clock was set.
#
then [5] [2] then user code* with
#
then [5] [7], then Door No.
#
then [5] [1]. A typical display is as
#
[3] then user code (not required if so
- 18 -
Page 19
Miscellaneous Commands (Cont’d)
5. Enter the result of step 4 as the adjust value. Valid entries are 00 for no
change, 1–29 for seconds to add (per day), or 1–29 for seconds to subtract
(per day). If the value entered is valid, an acknowledgement is sounded. If
the value entered is not within the valid range, an error is sounded.
TO DISPLAY ZONE DIRECTORY (LCD Keypads Only)
#
To view a list of the zones, press:
The zones will automatically scroll.
USER LOG VIEW (LCD Keypads Only)
[4].
To view the system log, pres s:
the display will show the most recent event.
Pressing either the
other key advances to the next valid log entry.
ON-LINE DOWNLOAD
If enabled by your system installer, an on-line download allows you to initiate
a remote communications session with the Central Station (CS) Downloading
computer from the control panel location. Typically, the CS initiates a remote
communications session. On-line Downloading allows you to call the office
(from the same telephone line as the panel), discuss the action requ ired, and
allow the CS operator to complete the request while on-line; no additional
telephone call is needed. Note that the office number that is dialed should be
the phone line that the downloadi n g computer is attached to. On-line
connection can be made as follows:
1. Uses the home telephone to dial the CS Downloading modem telephone
line. Connection is made with a person at the CS Downloading computer
and the account to be downloaded will be verbally identified.
2. Enter
received a request for a remote communications session, and to look for
the standard panel-to-CS protocol.
3. Once the standard connection is made, the necessary remote
communications sessions can take place (upload, download, remote
commands).
4. Hang up the telephone to prevent interference that may affect
upload/download data. The downloader software will automatically
terminate the connection after remote communications end.
# 9
[5] [3]. When the command is accepted,
#
STAY
. This will cause the control panel to react as if it
or
✱
keys exits this mode. Pressing any
- 19 -
Page 20
Using a Pager
If so progra mmed, the system can sen d messages to a pager. The messages
are displayed as follows:
ACCT E XX
where:
"ACCT" = the 4-digit central station No. 1 account number set by
"E" = the event code. There are 4 event types: alarms, troubles,
Openings = 0, Closings = 1, Alarm or Trouble = 9
If multiple events occur, only the signal for the highest-priority event is sent.
Events ranked from highest to lowest priority are alarm, trouble, open, and
close.
"XX" = the zone (01–08; OMNI-400 and 400EU or 01–12; OMNI-
your system installer. We suggest that you obtain the
number from your system installer and record it here.
"ACCT" =
openings, and closings. These event codes are as follows:
600 or 600EU) or user (01–15) designation, depending on
the event.
CHANGING THE PAGER PHONE NUMBER (FOLLOW-ME)
You can change your pager follow-me phone number as follows if your
installer enabled this feature:
1. Access pager number programming by pressing the following keys in
sequence:
[#], [5], and [8]
An acknowledge ment tone sounds to indicate pager numbe r programming
has been accessed.
The [#], [5], [8] command is accessible only while the system is disarmed and
the dialer, dialer delay, and bell are not active.
In pager phone number programming mode, only the LCD keypad provides
- 20 -
visual display of the numbers already programmed or numbers that are being
changed. The LED and fixed-word style keypads provide no visual keypad
display of these numbers.
Page 21
Using a Pager (Cont’d)
2. Enter your new pager phone number. Your new pager phone number may
consist of up to 16 characters (1–9, 0). It may be necessary to add time to
allow the pager to answ er before dialin g your pager num ber. To enter a 2second pause, press the [CODE] key. (Entering a 2-second pause is
optional and is not required to enter your pager phone number.) If you
pressed the [COD E] key, it counts as one ch aracter. The keypad w ill emit
a single acknowledgement chirp as ea ch number is pressed.
3. Press the [#] key after you have made your pager phone number changes.
Pressing
remaining locations. An acknowledgement tone sounds.
the [#] key saves your new pager number and nulls out the
To exit without sav ing chan ges, pr ess the [
programming. An acknowledgement tone sounds to indicate pager number
programming has been exited.
If you press the [
phone number, the system exits the pager phone number programming mode
without saving the changes.
If no key is pressed within 10 seconds, the pager phone number programming
mode times out and exits automatically without saving any information entered.
✱
] key without first pressing the [#] key to save your new pager
] key to exit pager phone number
✱
TURN PAGER REPORTING ON/OFF FOR OPEN/CLOSE
You can turn on/off the pager open–close reporting feature by entering the
following: [#] [8]
The display prompts you to toggle the feature on/off with the [#] key. To exit,
enter the [
✱] key.
- 21 -
Page 22
Testing the System
SYSTEM TEST
We recommend that you test your system once a week using the
following procedure:
NOTE:
perform this test.
1. Arm your security system.
2. Wait until your exit time is over. Then activate the system by opening a
protected zone (for example: a window or door).
3. Confirm that the alarm sounding device (bell or siren) sounds. If your
system is connected to a central station, the keypad will sound the
ringback tone to confirm that the signal was received.
4. Disarm the security system.
5. Call the central station to tell them you are finished testing.
BATTERY TEST
We recommend that you test your battery once a month. In order to test your
backup/standby battery, the following procedure should be followed:
1. Disconnect AC power to the system.
2. Observe that the A C indicator light on the keypad goes off.
3. Activ ate your alarm by performing the above SYSTEM TEST. Remember
to contact your central station if your system is monitored.
4. Reconnect AC power to the system.
The National Fire Protection Association publishes a standard for fire
warning equipment (NFPA publication #72). Further information can be
obtained by contacting: NFPA Public Affairs Dept., Batterymarch Park,
Quincy, MA 02269.
If your system is monitored, contact your central station before you
- 22 -
If you have any further questions about the operation of your system, please
contact your alarm company.
Page 23
DINING
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
BEDROOM
BDRM
BDRM
DINING
LIVING ROOM
TV ROOM
KITCHEN
BEDROOM
BEDROOM
TO
BR
LVNG RM
BASEMENT
KTCHN
.
CLOSED
DOOR
GARAGE
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
Recommendations on Smoke Detectors
With regard to the number and placement of smoke/heat detectors, we
subscribe to the recommendations contained in the National Fire Protection
Association’s (NFPA) Standard #72 noted below.
Early-warning fire detection is best achieved by the installation of fire
detection equipment in all rooms and areas of the household as follows: A
smoke detector installed outside of each separate sleeping area, in the
immediate vicinity of the bedrooms and on each additional story of the family
living unit, including basements and excluding cra wl spaces and unfinished
attics.
In addition, the NFPA recommends that you install heat or smoke detectors
in the living room, dining room, bedroom(s), kitchen, hallway(s), attic,
furnace room, utility and storage rooms, basements, and attached garages.
- 23 -
Page 24
•
FRONT
•
BACK
•
BATH
BEDROOM
KITCHEN
BACK DOOR
1 FLOOR
ST
BEDROOM
2 FLOOR
ND
BATH
BEDROOM
PORCH
CLOSET
BEDROOM
BEDROOM
Emergency Evacuation
Establish and regularly practice a plan of escape in the
event of fire. The following steps are recommended by the
National Fire Protection Association:
1. Position your detector or your interior and/or exterior
sounders so that they can be heard by all occupants.
2. Determine two means of escape from each room. One
path of escape should lead to the door that permits
normal exit from the building. The other is an
alternative route, such as through a window, should
your normal escape path be unpassable. Station an
escape ladder at such windows if there is a long drop to
the ground.
3. Sketch a floor plan of the building. Show windows,
doors, stairs, and rooftops that can be used to escape.
Indicate escape routes for each room. Keep these
routes free from obstruction and pos t copies of the
escape routes in every room.
4. Assure that all bedroom doors are shut while you are
asleep. This will prevent deadly smoke from entering
while you escape.
5. Try the door. If the door is hot, check your alternate
escape route. If the door is cool, open it cautiously. Be
prepared to slam the door shut if smoke or heat rushes
in.
6. When smoke is present, crawl on the ground. Do not
walk upright, since smoke rises and may overcome you.
Clearer air is near the floor.
7. Escape quickly; don’t panic.
8. Establish a common meeting place outdoors, away from
your house, where everyone can meet an d then take
steps to contact the authorities and account for those
missing. Choose someone to assure that nobody
returns to the house — many die going back.
- 24 -
Page 25
Glossary
AC/LB:
ALARM:
ARMED/DISARMED:
ARMED INDICATOR:
ARM-STAY:
AWAY:
BURGLARY/FIRE:
Small yellow LED on a LED keypad. When lit, the system is running
on primary power; when not lit, the system is running off the backup
battery; when flashing, the backup battery is low.
Sound from keypad or other horn/siren indicates a burglar alarm, fire
alarm, or other condition you should be alerted to.
These terms refer to the burglary portion of your security system.
There are several levels of opera tion that allow you to protect part of
your premises while you remain inside. Fire sensors and other
emergency and en vironmental features are always active and ready
(armed); they are not affected in any way by arming or disarming the
burglary portion of your security system. See ARMED-INSTANT,
ARMED-STAY, and STAY.
Red light in the upper portion of the keypad labeled "Armed." When
lit, some part of the burglar alarm system is armed; when not lit, the
burglary portion of the system is disarmed.
A system setting that turns on the perimeter protection of the
building but allows movement throughout the interior.
A system setting that protects the premises while it is unoccupied. All
burglary sensors are active.
The two major functions of a security system. Fire protection is
always armed and cannot be disarmed. The burglary sensors protect
against unauthorized entry into your premises. The burglary
protection can be armed and disarmed and programmed for special
levels of access and notification.
BYPASS FEATURE:
BYPASS BUTTON:
The Bypass feature allows you to exclude a selected zone or zones
from the burglar alarm protection.
A button on the keypad used to activate the Bypass feature.
- 25 -
Page 26
Glossary (Cont’d)
CENTRAL STATION:
CHIME FEATURE:
DISARMED:
DURESS:
ENTRY DELAY:
EXIT DELAY:
INTERIOR ZONE:
KEYPAD:
PANIC BUTTON:
The signal monitoring center contacted by your security s yst em over
the telephone and/or other communication channels when alarms are
activated if your system is programmed to communicat e alarms off
site. The central station will follow their procedures and your
instructions for contacting the proper authorities when a signal is
received.
An optional feature that causes the keypad to chime for one second
when selected doors are opened when the bu rglary protection is off or
disarmed. Once programmed by your installer, you can turn Chime
on and off by pressing [#] + [6].
See ARMED/DISARMED.
Duress is a system feature that you may have programmed into your
system. If someone forces you to disarm your system, entering the
special Duress user code disarms the system and sends a silent
duress emergency signal to the central station so personnel there can
respond appropriately.
The period of time allowed between opening a designated entry/exit
door and disarming the alarm system before the system will register
an alarm condition. This is determined at the time of installation.
Your system supports two entry times, allowing you to have a
different length of time for different doors.
The period of time allowed between arming the system and leaving
through a designated exit/entry door before the system will register
an alarm condition. This is determined at the time of installation.
An interior zone is a group of points that protect the interior of your
premises. You may want to arm the perimeter port ion of your system
while leaving the interior zones disarmed to allow you to open
interior doors and pass interior motion detectors without causing an
alarm.
A keypad is your link into your system. It displays alarm and trouble
messages, shows faulted zones and allows you to arm/disarm the
system by using the buttons. Your system will have one or more
keypads.
A push button that allows you to signal the central station that you
need immediate assistance. Your system has programmable Keypad
Send Help Alerts that can also serve as Panic buttons.
- 26 -
Page 27
Glossary (Cont’d)
PERIMETER ZONE:
SENSOR:
SILENT CONDITION:
SYSTEM:
A perimeter zone is a group of points that protect the exterior of your
premises. Your outside doors and windows would be programmed as
a perimeter zone.
The actual alarm sensor, detector, or device installed to detect an
intrusion, fire, or environmental problem. Examples include: door
contacts, window contacts, motion sensors, glassbreak sensors, smoke
detectors, rate-of-rise heat detectors, temperature sensors,
flood/water sensors, and carbon monoxide gas detectors.
Most types of alarms and troubles alert you with the keypad sounder
and the sirens, horns, or speakers l ocated in your premises. The
intent is to advise you of the alarm or trouble and allow you to
respond promptly. The audible sounds also let an intruder know that
he has been detected and will hopefully scare him away. In some
circumstances, an audible alarm might put your life in danger. For
that reason, those alar ms are programmed as silent conditions. For
an example, see DURESS.
Your security system is composed of three main parts: 1) the control
panel, which functions as the system br ain and the link to the
monitoring agency (central station); 2) the keypad(s), which provide
you with system status and allow you to input commands; 3) security
sensors such as door and window contacts, motion sensors, smoke
detectors and other sensors as required to detect intrusion, fire, and
other conditions for your premises.
USER CODE:
ZONE:
A user code is a 4- or 6-digit code that is required to operate the
system. The system supports up to 15 separate user codes. The
system supports one master user who can a dd/delete other user
codes. Two of the user codes may be dedicated to special functions as
defined by your alarm company at the time of installation. (See User Code Assignments in this manual)
A zone is a collection of sensors with common characteristics grouped
together for your operating convenience. The system will support 6
zones or groupings.
- 27 -
Page 28
RADIO FREQUENCY EMISSIONS STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
INDUSTRY CANADA
This Class B digital apparatus complies with Canadian ICES-003.
Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
TELEPHONE/MODEM INTERFACE STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68
This equipment complies with Part 68 of the FCC rules . On the front cover of this equipment is a label that
contains the FCC registration number and Ringer Equivalenc e Number (REN). Y ou must provide this inform ati on
to the telephone company when requested.
This equipment uses the following USOC jack: RJ31X
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is
subject to state tariffs. This equipment is hearing-aid compatible.
INDUSTRY CANADA
: The Industry Canada Label identifies certified equipment. This certif ication means that the equipment
NOTICE
meets telecommunications network protective, operational and safety requirements as prescribed in the
appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the
equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilit ies of the
local telecommunications company. The equipment must also be installed using an acceptable method of
connection. The customer should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment s hould be coordinated by a rep resentat ive des ignated by the suppl ier. Any repairs
or alterations made by the user t o this equipment, or equipm ent malfunctions, may give the telecommunications
company to request the user to disconnect the equipment.
Users should ensure for their own protection t hat the electrical ground connecti ons of the power utility, telephone
lines and internal metallic water pipe system, if present, are connected together, This precaution may be
particularly important in rural areas.
Caution:
inspection authority, or electrician, as appropriate.
Users should not attempt to mak e such connecti ons themselves but should contact appropri ate elect ric
RINGER EQUIVALENCE NUMBER NOTICE
The
Ringer Equivalence Number
maximum number of terminals allowed to be connec ted t o a tel ephone i nterfac e. The t ermi nation on an interf ace
may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence
Numbers of all the devices does not exceed 5.
(REN) assigned to each terminal device provides an indication of the
- 28 -
Page 29
INDUSTRIE CANADA
L’étiquette d’Industrie Canada identifie l e matériel homologué. Cette étiquette certifie que le matériel est
AVIS:
conforme aux normes de protection, d’exploitation et de sécurité des réseaux de téléc ommunications, comme le
prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère
n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utili sateur.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de
l’enterprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode
acceptée da raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions
énoncées ci-dessus n’empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur.
L’entreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à la suite de
réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit s’assurer que tous l es fils de mise à la terre de la source d’energie
électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sont raccordés ensemble.
Cette précaution est particulièrement importante dans les régions rurales.
Avertissement:
service d’inspection des installations électriques, ou à un électrici en, s el on le cas.
AVIS: L’indice d’équivalence de la sonnerie
maximal de terminaux qui peuvent être rac cordés à une interface. La terminaison d’une int erface téléphonique
peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme d’indices
d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.
L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un
(IES) assigné à chaque dispositif terminal indique le nombre
TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems , disconnect the control by remov ing the plug from the RJ31X wal l
jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the
system. Do not disconnect the phone connection inside the control/c ommunicator. Doing so will result i n the loss
of your phone lines. If the regular phone works correct ly after the control/communicator has been disconnected
from the phone lines, the control/communicator has a problem and should be returned for repair. If upon
disconnection of the control/communicator, there is still a problem on the line, notify the telephone company that it
has a problem and request prompt repair service. The user may not under any circumstances (in or out of
warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized service
agency for all repairs.
This control unit was manufactured under rigid quality standards and complies with all UL requirements
for its intended use. Maintenance is best performed by your installing company with trained service
personnel.
O560 DECLARATION OF CONFORMITY
OMNI-400, OMNI-400EU, OMNI-600, and OMNI-600EU are in conformity with the
essential requirements as described in Directive 1999/ 5/EC and satisfy all the
technical regulations applicable to the product within this directive
EN 50081-1:1992 EN 50130-4:1998 EN 60950:1992 TBR 21
This apparatus has been assessed for connection to the following circuits
Public Switched Telephone Networks (PSTN) -non DDI
Private Branch Exchange (PBX)
- 29 -
Page 30
Limitations of This Alarm System
While this system is an advanced design security system, it does not offer guaranteed
protection against burglary, fire, or other emergency. Any alarm system, whether
commercial or residential, is subject to compromise or failure to warn for a variety of
reasons. For example:
Intruders may gain access through unprotected openings or have the technical
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other
sensing devices will not work without batteries, or if the batteries are not put in
properly. Devices powe red solely by AC will not work if their AC power supply is cut
off for any reason, however briefly.
Signals sent by wireless tra nsm itte rs may b e blo cked or re fle cted b y metal before the y
reach the alarm receive r. Even if the signal path has been re cently checked during a
weekly test, blockage can occur if a metal object is moved into the path.
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detecto rs have pla yed a ke y role i n reducing re siden tial fire deaths , they
may not activate or provide early warning for a variety of reasons in as many as 35%
of all fires. Some of the reasons smoke detectors used in conjunction with the System
may not work are as follows: Smoke detectors may not sense fires that start where
smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the
other side of closed doors. Smoke detectors also may not sense a fire on another level
of a residence or building. A second-floor detector, for example, may not sense a firstfloor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke
detector can sense every kind of fire every time. In general, detectors may not always
warn about fires caused by carelessness and safety hazards like smoking in bed,
violent explosions, escaping gas, improper storage of flammable materials, overloaded
electrical circuits, children playing with matches, or arson. Depending on the nature
of the fire and/or the location of the smoke detectors, the detector, even if it operates
as anticipated, may not provide sufficient warning to allow all occupants to escape in
time to prevent injury or death.
Passive Infrared Motion Detectors can detect intrusion only within the designed
ranges as diagrammed in their Installation Manual. Passive Infrared Detectors do not
provide volumetric area protection. They do create multiple beams of protection, and
intrusion can only be detected in unobstructed areas covered by the beams. They
cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed
doors, glass partitions, glass doors or windows. Mechanical tampering, masking,
painting or spraying, of any material on the mirrors, windows or any part of the
optical system can reduce their detection ability. Passive Infrared Detectors sense
changes in temperature; however, as the ambient temperature of the protected area
approaches the temperature range of 90º to 104º Fahrenheit (32º to 40º Celsius), the
detection performance can decrea se.
- 30 -
Page 31
Limitations of This Alarm System
Alarm warning devi ces such as sire ns, bells or horn s may not ale rt people or wake up
sleepers who are located on the other side of closed or partly open doors. If warning
devices sound on a different level of the residence from the bedrooms, then they are
less likely to waken or alert people inside the bedrooms. Even persons who are awake
may not hear the warning if the alarm is muffled by noise from a stereo, radio, air
conditioner, other appliances, or by passing traffic. Finally, alarm warning devices,
however loud, may not warn hearing-impaired people or waken deep sleepers.
Telephone lines needed to transmit alarm signals from a premises to a central
monitoring station may be out of service or temporarily out of service. Telephone lines
are also subject to compromise by sophisticated intruders.
However, even if the system responds to the emergency as intended, occupants may
have insufficient time to pro tect themselves from the emerge ncy situati on. In the case
of a monitored alarm system, authorities may not respond appropriately.
This equipment, like other electrical devices, is subject to component failure. Even
though this equipment is designed to last as long as 20 years, the electronic
components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire
occurs is inadequate maintenance. This alarm system should be tested weekly to make
sure all sensors are working properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm
system is not a substitute for insurance. Homeowners, property owners and renters
should continue to act prudently in pro tecting themselves and continue to insure their
lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe
it to themselves and their loved ones to learn about these developments.
(Cont’d)
- 31 -
Page 32
LIMITED WARRANTY
Fire Burglary Instruments, Inc., a subsidiary of Pittway Corporation, and Pittway Corporation, its divisions,
subsidiaries and affiliates ("Seller"), 180 Michael Dri ve, Syosset, New York 11791, warrants its security equipm ent
(the "product") to be free from def ects in material and work manship for one year from dat e of original purchas e,
under normal use and service. Seller's obligation is limit ed to repairi ng or replac i ng, at i ts option, free of charge for
parts, labor, or transportation, any product proved to be defec tive in materials or work manship under normal use
and service. Seller shall have no obligat ion under thi s warrant y or otherwis e if the product is al tered or improperly
repaired or serviced by anyone other than the Seller. In case of defect, contact the security professional who
installed and maintains your security equipment or the Seller for product repair.
This one-year Limited Warranty is in lieu of all other expressed warranties, obligat ions or liabilities. THERE ARE
NO EXPRESS WARRANTIES THAT EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED WARRANTIES,
OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS PRODUCT, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, ARE LIMITED IN DURATI ON TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL
PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE BROUGHT WITHIN 60 MONTHS FROM DATE OF
ORIGINAL PURCHASE. IN NO CASE SHALL SELLER BE LI ABLE TO ANYONE FOR A NY CONSEQUENTIAL
OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED,
OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED
BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Some states do not allow limitation on how long an implied
warranty lasts or the exclusi on or limitation of incidental or consequential damages , so the above limitation or
exclusion may not apply to you.
Seller does not represent that the product may not be compromised or circumvented; that the product will prevent
any personal injury or property loss by burglary, robbery, fi re or otherwise; or that the product will in all cases
provide adequate warning or protec tion. Buyer understands that a properly ins talled and maintained alarm may
only reduce the risk of a burglary, robbery, f ire or other events occurring without provi ding an alarm, but it is not
insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a
result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY
DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAIL ED TO GIVE WARNING. HOWEVER,
IF SELLER IS HELD LIABLE, WHETHER DIRECT LY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING
UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S
MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT,
WHICH SHALL BE THE COMPLETE AND EXCLUSI VE REMEDY AGAINST SELLER. This warranty gives you
specific legal rights, and you may also have other rights, which vary from state to state. No increas e of alteration,
written or verbal, to this warranty is authorized.