Fbii OMNI-408, OMNI-408EU User Manual

6HFXULW\6\VWHP
011,,
220
011,,((88
220
8VHU*XLGH
N9942-2 1/01
TABLE OF CONTENTS (cont’d)
QUICK REFERENCE.....................................3
System Turn On..........................................3
System Turn Off..........................................3
System Turn On/Stay Inside.......................3
System Turn On/Stay Inside/Instant Mode.3
Smoke Detector Reset................................3
INTRODUCTION............................................5
SYSTEM REFERENCE .................................6
SYSTEM OPERATION ..................................9
To Turn the System On and Leave ............9
When the System is Not Ready................10
To Turn the System On and Stay Inside ..10 To Turn the System On In Instant Mode and
Stay Inside................................................11
To Turn the System On In Instant Mode ..12
To Bypass a Zone.....................................12
To Unbypass a Zone ................................13
Turning the System Off.............................13
USER CODES..............................................15
Adding/Changing a User Code.................15
Deleting a User Code ...............................15
PAGING FEATURE .....................................16
Follow-Me Displays .................................. 16
Changing the Pager Follow-Me Phone
Number.....................................................16
KEYPAD FUNCTIONS.................................18
System Turn On (Maid Code)...................18
Send Help Conditions...............................18
Set Time and Date....................................20
Turn Chime On/Off ...................................20
TESTING THE SYSTEM..............................21
System Test..............................................22
Battery Test ..............................................22
RECOMMENDATIONS ON SMOKE
DETECTORS...............................................22
EMERGENCY EVACUATION ......................23
SYSTEM LIMITATIONS...............................26
– 2 –
GLOSSARY..................................................29
Quick Reference
System Turn On
Check to make sure the system is ready — Green READY LED is lit. Enter your 4-digit User Code (or press the ARM button on your keyfob). The ARMED LED goes on. Exit through a door designated by your installer as an exit/entry door.
System Turn Off
Enter through door designated by your installer as an exit/entry door. Enter your 4-digit User Code (or press the DISARM button on your
keyfob). The ARMED LED goes out.
System Turn On/Stay Inside
Check to make sure the system is ready — Green READY LED is lit.
Press
The ARMED and STAY LEDs light.
You must turn the system off if you want to open the door or leave the premises after the exit time has passed.
System Turn On/Stay Inside/Instant Mode
Check to make sure the system is ready — Green READY LED is lit.
Press
The ARMED, INSTANT, and STAY LEDs are all lit.
Smoke Detector Reset
Enter your 4-digit User Code.
STAY
INSTANT
followed by your User Code.
then
STAY
followed by your User Code.
– 3 –
Quick Reference (cont’d)
The following table lists the “Quick Commands” available with this control
.
Keystroke Quick Command Keypads
#
1
#
2
[BYPASS] + Zone No.
#
3
#
4
#
55
#
56
#
58
#
6
#
7
Quick Arm All keypads If system is ready, allows you to arm the system without
Force Arm All keypads Allows you to arm the system even i f some zones are
Quick Bypass All keypads
Set Time All keypads
Zone Directory LCD only Displays listing of zones in system.
Display Firmware Version LCD only Displays version of your OMNI-408 firmware.
Display Keyfob Battery Status All keypads Allows you to test battery status of your keyfob. Upon entry
Change/View Pager Number All keypads Allows you to redirect pager output to a different pager
Display/Toggle Chime Mode All keypads Allows you to change the status of the chime function.
Display Current Time LCD only Allows you to view the current system time.
Description
requiring your User Code. Your User Code is always needed to disarm the system.
faulted. These zones are automatically bypassed and are unprotected.
Allows you to bypass a specific zone number. Must be enabled by yo ur inst al ler.
Allows entry of the current system time (hours, minutes, month, day, year).
of this mode, press any button on the keyfob and the keypad will display if your battery is low.
number. Phone numbers are displayed only on LCD keypads.
#
– 4 –
8
User Page Toggle All keypads Allows you to turn the pager mode on or off. Keypad
displays the current s ystem status.
Introduction
Introduction
Congratulations on your decision to protect your home or business with the OMNI-408 security system. You have chosen a reliable, state-of-the-ar t secu rity system that i s rema rkably easy to operate. Representatives from your local security company, who can explain the specifics of your system, have professionally installed your system.
The keypad is the input and display device for your security system. Your system can use either the OMNI-KP, OMNI-LCD or OMNI-LED keypads. The OMNI-KP keypad displays the system status with fixed words, the OMNI-LCD keypad displays two lines of text, and the OMNI-LED keypad displays the current zone status, including alarms, bypasses, and f a ults, using LEDs. Each condition causes the LEDs to operate differently.
Throughout this guide, the following conventions are used to display the keystrokes required to perform functions.
BYPASS
INSTANT
STAY
CODE
Please keep your guide in a convenient location so you can refer to it if needed.
Key labeled [BYPASS] Key labeled [INSTANT] Key labeled [STAY] Key labeled [CODE]
Enter your four-digit User Code.
– 5 –
System Reference
System Reference
ZONE DESCRIPTION
1 2 3 4 5 6 7 8
ENTRY TIME 1 DOOR
ENTRY TIME 2
DOOR
EXIT
TIME*
* Exit time is the same for all designated entry/exit doors. The following SEND HELP ALERTS can be programmed into your
system. Both keys must be pressed at the same time to activate the alert. The keys you press depend on which type of keypad you have. Your installer will show you how to activate these emergency keys.
DESCRIPTION KEYS
[#] and [*] [7] and [9] [1] and [3]
See page 7 of this User Guide for pictures of the OMNI-KP, OMNI-LCD, and OMNI-LED keypads.
– 6 –
OMNI-KP KEYPAD
System Reference (cont’d)
ARMED
READY
STAY
BYPASS
INSTANT
CODE
1 4 7
2 5 8 0
3 6 9 #
OMNI-LCD AND OMNI-LED KEYPADS
ARM AC / LB
READY
ARMED
READY
STAY
BYPASS
INSTANT
CODE
OMNI-LCD Alpha Keypad
2
1 4 7
3
5
6
8
9
0
#
OMNI_LCD
STAY
INST TX LB
RF. SPRV.
1 3
2
4 6
5
7 9
8 0
STAY
BYPASS
INSTANT
OMNI-LED Keypad
#
CODE
OMNI_LED
– 7 –
System Reference (cont’d)
USER ID ASSIGNED TO
1 (MASTER USER 1) 2 3 4 5 6 Duress**
* The Master User can add, change, or erase other User Codes. ** If enabled, this User Code will transmit a duress signal to the central station.
MONITORING STATION INFORMATION
Account No. Telephone No.
– 8 –
System Operation
You can turn the burglar portion of your security system on and off. Before you can turn the system on, it must be “ready.” If you have a protected door open, or if someone is moving in view of a motion detector, the system will not display “
The system is ready if the READY LED is lit and the display shows:
System Operation
READY
.”
LCD Keypad:
SYSTEM READY
NOTE:
If programmed by your installer, you may arm the system if a
Fixed-Word Keypad:
READY LED lit
delay or interior zone is faulted. However, faulted zones must be restored before your exit time expires or an alarm or zone bypass will result. Ask your installer if your system has this feature and, if so, if it causes an alarm or zone bypass.
To Turn the System On and Leave
Enter your User Code. The
ARMED
LCD Keypad:
ON: AWAY
LED goes on an d the display shows:
Fixed-Word Keypad:
ARMED LED lit
Exit through a door designated by your installer as an exit/entry door. You must leave within the exit time programmed by your installer. Refer to the reference sheet for the time that has been set for your system.
– 9 –
System Operation (cont’d)
When the System is Not Ready
If the system is display indicates which zone or zones are not ready.
Determine which zone or zones are not ready, resolve the problem, and turn the system on normally. If the problem cannot be resolved, you may bypass the zone that is not ready. Bypassing should only be done if the problem on the zone cannot be resolved, OR if you intentionally wish to leave the zone off. For example, you would leave the zone off if you plan to keep the window open for ventilation. Zones that are bypassed are not protected when the system is on. Refer to the paragraph entitled, “To Bypass a Zone” for a description of the procedure.
To Turn the System On and Stay Inside
To turn the perimeter portion of your burglar alarm on and move around freely inside the premises, use the
Check to make sure the system is ready. When it is ready, press:
STAY
When the system has been turned on successfully, the ARMED LED is on, and the following is displayed:
ready to be armed, the READY LED is
not
STAY
followed by your User Code.
mode.
off
and the
– 10 –
LCD Keypad:
ON: STAY
REMEMBER:
door or leave the premises after the exit time has passed.
You must turn the system off if you want to open the
Fixed-Word Keypad:
STAY
Loading...