Fastron Parts VISION Series General Manual

VISION Series
Vertical Oven Controller with Shelf ID
231-60230-03
Programming Guide
Toll-Free Technical Support
24 Hours A Day, 365 Days A Year
1-800-243-9271
This document contains confidential
information. The dissemination, publication,
copying, or duplication of this document or
the software described herein without prior
written authorization is strictly prohibited.
w
w
w
.
f
a
s
t
i
n
c
m
.
o
c
F
-
0
0
8
-
1
the time is right.
N
O
R
T
S
A
$5.00 USD
Important Notices
FAST is not liable for any use
of product not in accordance with its installation and operating instructions.
Before using this equipment, or for any questions on the opera­tion of the appliance, consult and follow all instructions and safety warnings found in the appliance operator’s manual supplied from the manufacturer of the appli­ance.
Not all features are available on some models.
Controller Operating Environment
Cleaning the Controller
Using a clean damp cloth, wipe down your controller daily.
Do not allow oil to build up on any part of the controller.
NEVER use chemical or abrasive cleaners on your controller. The controller’s overlay may be damaged.
The solid state components in this controller are designed to operate reliably in a temperature range up to 158°F/ 70°C. Before installing this controller, it should be verified that the ambient temperature at the mounting location does not exceed 158°F/ 70°C.
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior written authorization is strictly prohibited.
2
Vision Vertical Oven Controller
www.fastinc.com 1-800-243-9271
229-51337D © 2007-2010 FAST
Programming the Controller
Recipe Programming—1724
Entering Programming and Changing Recipes
Press and hold the “P” for 3 seconds.
Product Cnt will be displayed. Press the down arrow.
Programming will be displayed, then press the “P” key.
ENTER CODE will be displayed.
From ENTER CODE, type in 1724, then press the “P” key.
Display will show RECIPE. Press the “P” key and all product LEDs will light up and the display will
read Select Product To Program.
Press the Product key you would like to program.
NOTE: Some controls have different options than what are listed.
ALL will be displayed.
NOTE: Depending on the model of the unit, you can either press the “P” key to change all of the programmable settings or you can scroll using the arrow Up or Down keys to any of the specific options.
Stage X Temp will be displayed with the current set temp XXXF. To change temperature, type in your
new temperature. Then press the “P” key.
Stage X Timing will be displayed, then either STRAIGHT, FLEX or SENSITIVITY. Use the left or right
arrow keys to change between the 3 settings. Then press the “P” key.
Stage X Sens will be displayed with the current sensitivity setting 0-9. To change the sensitivity
setting, type in your new setting. Then press the “P” key.
Stage X Fan Spd will be displayed, then either HIGH or LOW. Use the left or right arrow keys to change
between the 2 settings. Then press the “P” key.
Stage X Fan Cyc will be displayed, then either FULL, HEAT, or PULSE. Use the left or right arrow keys to
change between the 3 settings. Then press the “P” key.
If PULSE is selected: Stage X Fan ON will be displayed with the current time XX:XX. To change the Fan ON time, type in a
new time. Then press the “P” key.
Stage X Fan OFF will be displayed with the current time XX:XX. To change the Fan OFF time, type in a
new time. Then press the “P” key
From ALL being displayed press the “P” key.
Product Name will be displayed. To scroll through the Library, use the arrow Up or Down keys or you can use the letters on each key to start a word from the Library. Once you have chosen your word, press the “P” key.
Shelf Cook NO will be displayed. Use the Left or Right arrow keys to change from YES or NO for Shelf Cook. Then press the “P” key. NOTE: If YES is selected, you will not be given an option for extra stages.
Stage X Time will be displayed with the current set time XX:XX. To change, type in a new time, then
press the “P” key.
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior written authorization is strictly prohibited.
Vision Vertical Oven Controller
www.fastinc.com 1-800-243-9271
NOTE: Each product key can be programmed with up to 10 stages. If no additional stages are required, set the time to zero, and press the “P” key to continue to Alarm Time.
Alarm X Time will be displayed with the current time XX:XX. To change the alarm time, type in a
new time. Then press the “P” key.
Alarm X Name will be displayed with the current name. To scroll through the Library, use the arrow Up or Down keys or you can use the letters on each key to start a word from the Library. Once you have chosen your word, press the “P” key.
Alarm X Done will be displayed along with either AUTOMATIC or MANUAL. Use the left or right arrow
keys to change between the 2 settings. Then press the “P” key.