FASTflo WH42, WH56, WHX56, LWH56, LWHX56 Installation Design Manual

Working towards a cleaner future
FASTflo
Installation Design Guide
This manual must be kept with the appliance October 2010
Part No E835
Continuous Flow Wall Hung Balanced Flue Water Heaters for Natural Gas and Propane
WH42, WH56, WHX56, LWH56, WHX56, LWHX56
Reproduction of any information in this publication by any method is not permitted unless prior written approval has been obtained from Andrews Water Heaters.
Andrews Storage Water Heaters have been designed and manufactured to comply with current international standards of safety. In the interests of the health and safety of personnel and the continued safe, reliable operation of the equipment, safe working practices must be employed at all times. The attention of UK users is drawn to their responsibilities under the Health and Safety Regulations 1993.
All installation and service on Andrews Water Heaters must be carried out by properly qualified personnel and, therefore, no liability can be accepted for any damage or malfunction caused as a result of intervention by unauthorised personnel.
Andrews Water Heaters’ policy is one of continuous product improvement and, therefore, the information in this manual, whilst completely up to date at the time of publication, may be subject to revision without prior notice.
Further information and assistance can be obtained from:
Andrews Water Heaters Wood Lane, Erdington, Birmingham B24 9QP
Tel: 0845 070 1055 Fax: 0845 070 1059 Email: andrews@baxigroup.com Website: www.andrewswaterheaters.com
THE ANDREWS WATER HEATERS COVERED IN THIS GUIDE ARE FOR USE WITH NATURAL GAS OR PROPANE ONLY
Copyright Andrews Water Heaters 2010
Andrews Installation Design Guide for WH and WHX Model Water Heaters
Fig No. DESCRIPTION
1 Typical Installation - Single Heater
2 Typical Installation - Single Heater with Secondary Return
3 Typical Installation - Two Heaters
4 Typical Installation - Two Heaters with Quick Connect Cord
5 Typical Installation - Three Heaters with Secondary Return
6 Typical Installation - Four Heaters with Electronic System Controller Kit
7 Technical Note - Water Flow Rates and Performance Chart
8 Typical Installation - Electronic System Controller Kit
9 Technical Note - Unvented System Kits
10 Typical Installation - Single Heater with ST Range Storage Cylinder
11 Typical Installation - Two Heaters with ST Range Storage Cylinder,
Quick Connect Cord and Secondary Return
12 Typical Installation - Three Heaters with ST Range Storage Cylinder
and Secondary Return
13 Technical Note - Flow Rate Head Loss and Pump Sizing
14 Technical Note - Pump Curves
15 Heater Dimensions - WH56 and LWH56
16 Heater Dimensions - WHX42, LWHX42, WHX56 and LWHX56
17 WH42, LWH42, WH56 and LWH56 Pre-assembled dual manifold unit dimensions
18 WH42, LWH42, WH56 and LWH56 Pre-assembled triple manifold unit dimensions
19 WHX56 and LWHX56 Pre-assembled dual manifold unit dimensions
20 WHX56 and LWHX56 Pre-assembled triple manifold unit dimensions
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Remote controller kit (part no. B285)
Gas
HWS flow
Hot Outlets
Water Supply Pressure
Min 1.0 bar Max 10.0 bar Min flow 3.5 ltrs/min
1. Stop cock
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1
Andrews WH and WHX Single Water Heater Installation Without Secondary Return
Fig No.1
Cold Supply
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Remote controller kit (part no. B285)
Gas
HWS flow
Hot Outlets
Cold Supply
1. Stop cock
2. Strainer
3. Pressure reducing valve
4. Non return valve
5. Expansion vessel
6. Expansion valve + tundish
7. Andrews bronze pump c/w ball valve unions (part no. B249)
Water Supply Pressure
Min 1.0 bar Max 10.0 bar Min flow 3.5 ltrs/min
Bronze secondary return pump see Fig. No’s. 13 and 14
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1
2
3 4
5
6
7
Andrews WH and WHX Single Water Heater Installation with Secondary Return
Fig No.2
Remote controller kit (part no. B285)
Gas
HWS flow
Where output may be below 7 ltrs/min see Fig. No. 4
Cold Supply
1. Stop Cock
Water Supply Pressure
Min 1.0 bar Max 10.0 bar
Gas rate for NG units
WH42 - 5.1 m
3
/hr
WH56, WHX56 - 6.5 m
3
/hr
Gas rate for Propane units
LWH42 - 1.9 m
3
/hr
LWH56, LWHX56 - 2.5 m
3
/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1
Andrews WH and WHX Multiple Water Heater Installation without Secondary Return
Fig No.3
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Andrews WH and WHX Multiple Water Heater Installation with Quick Connect Cord Kit
Fig No.4
Single remote controller
Gas
HWS flow
Hot Outlets
Cold Supply
1. Stop Cock
Water Supply Pressure
Min 1.0 bar Max 10.0 bar
Quick Connect Cord Kit (part no. B286)
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Andrews WH and WHX Multiple Water Heater Installation with Secondary Return
Fig No.5
Remote controller kit (part no B285)*
*An Electronic System Controller Kit
can be used as an alternative when manifolding up to six units. (see Fig. No’s 6 and 8)
Gas
HWS flow
Hot Outlets
Cold Supply
Bronze secondary return pump see Fig. No
’s. 13 and 14
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1 2 3 4
7
5
6
4
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
1. Stop cock
2. Strainer
3. Pressure reducing valve
4. Non return valve
5. Expansion vessel
6. Expansion valve + tundish
7. Andrews bronze pump c/w ball valve unions (part no. B249)
Andrews WH56 and WHX56 Multiple Water Heater Installation with System Controller Kit
Fig No.6
Single remote controller
System Controller in unit No. 1 (see Fig. No. 8)
Gas
HWS flow
Hot Outlets
Cold Supply
Gas rate per NG units
WH42 - 5.1 m
3
/hr
WH56, WHX56 - 6.5 m
3
/hr
Gas rate for Propane units
LWH42 - 1.9 m
3
/hr
LWH56, LWHX56 - 2.5 m
3
/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1
1. Stop Cock
Water Supply Pressure
Min 1.0 bar Max 10.0 bar
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Andrews WH and WHX Water Flow Rates
Performance Chart
Fig No.7
Andrews Model
Temperature Temperature Temperature Temperature Temperature Temperature
Reference
Rise 25
ºC Rise 35
ºC Rise 45ºC Rise 55ºC Rise 65ºC Rise 75ºC
L sec L min L sec L min L sec L min L sec L min L sec L min L sec L min
WH42,LWH42 0.40 24.0 0.29 17.4 0.22 13.2 0.18 10.8 0.15 9.2 0.13 8.0
WH56, LWH56 0.53 31.8 0.38 22.8 0.30 18.0 0.24 14.4 0.20 12.3 0.18 10.6
WHX56,LWHX56 0.53 31.8 0.38 22.8 0.30 18.0 0.24 14.4 0.20 12.3 0.18 10.6
The flow rate will vary dependant upon the temperature selected at outlet and the incoming water temperature. The flow rate can be calculated using the following formula or by reference to the charts above.
In addition to the above the maximum flow through each heater is pre-set independent of temperature, maximum flow rate for the WH42 is 24 L/min and maximum flow rate for the WH56 and WHX56 is 31.8 L/min.
WH42, LWH42 = 42 kW output WH56, LWH56 = 55.8kW output WHX56, LWHX56 = 55.8 kW output
(heater output) kW
Δt (temperature rise) x 4.2 specific heat
Flow rate L/S =
Water flow at different temperature rises
Andrews System Controller Kit
(Part No. B287) for WH56, LWH56, WHX56
Fig No.8
P C B
P C B
P C B
P C B
P C B
P C B
The System Controller Kit can be used as an alternative to the Quick Connect Cord Kit (two unit installation) or for controlling up to six manifolded water heaters. The master unit (No.1) contains the System Controller module and includes plug connectors to enable the control cords from the other units to be connected up to the master unit. In addition the System Controller incorporates the following standard features, BEMS fault indication, Remote ‘Power On’ indication, Primary Pump connection via cylinder thermostat, Secondary Circulation Pump connection and Remote Switching. A comprehensive installation manual is available from our sales department.
Single remote controller
System controller Kit (Part No. B287)
Typical installation
System operation
The control panel randomly selects some heaters at the ready stage and some at the standby stage, and heaters will start depend
ent upon
water flow and temperature settings. The system rotates the lead and standby units after every eight hours operating time. As t
he flow rates
increases additional units will fire thus maintaining the required system flow temperature. The remote controller must be conne
cted to Unit No. 1 and temperature settings on this controller will be communicated to the other manifolded heaters on the system. The System Controller is not required when the installation incorporates a storage cylinder/ buffer vessel or if a constant large volume of hot water
is required.
Unit No.1
Unit No.2Unit No.3
Unit No.4Unit No.5Unit No.6
Andrews WH & WHX Unvented System Kits
Fig No.9
If continuous flow water heaters are used on circulation systems or linked to a storage cylinder/buffer vessell an unvented system kit is required to allow for expansion of the hot water system. The kit includes the necessary safety devices required to conform to the current building regulations.
Three sizes of kit can be supplied and each contains a combined strainer/pressure reducing valve set to 3.5 bar, check valve, expansion valve set to 6.0 bar, tundish, 5 litre expansion vessel, wall bracket and hose.
When the system includes a storage cylinder/buffer vessel, a combined temperature/pressure relief valve must be sized to suit the total input of all the water heaters installed (see table below). This valve must be located at the top of the storage unit (see Fig. No. 10). In addition the size of the expansion vessel must also be increased to suit both the storage cylinder plus the contents of the system pipework (see expansion vessel table).
Unvented System Kit
Part No. Size B235
3
/
4 inch dia.
B234 1 inch dia. B276 11/
4 inch dia.
Expansion Vessel
Part No. Size C782 25 litre, 3.5 bar C789 40 litre, 3.5 bar E047 60 litre, 3.5 bar C890 80 litre, 3.5 bar
Temperature and pressure Relief Valves Tundishes
Part No. Total Output Quantity & Size of Valves Part No. Size
C380
Up to 56kw 1 x 1 inch
C384 1 inch - 11/
4 inch
E242 Up to 112kw 1 x 11/
2 inch E326 1 1/2 inch - 2 inch
E242+C456 Up to 126kw 1 x 11/
2 inch + 1 x
3
/
4 inch E497 2 inch - 2
1
/
2 inch
E291 Up to 168kw 1 x 2 inch E497 2 inch - 21/
2 inch
E291+C380 Up to 224kw 1 x 2 inch + 1 x 1 inch E497+C384
2 inch - 21/
2 inch+ 1 inch - 1
1
/
4 inch
Andrews WH and WHX Single Water Heater Installation with ST Range Storage Cylinder
Fig No.10
Remote controller set to 70ºC
Gas Supply
Pump (See Fig. No’s. 12/13)
HWS flow
Storage cylinder
Tank thermostat kit (part no.
C927) set to 65ºC
Cold Supply NB. Size mains pressure group to suit building design flow rate
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1 2 3 4
5
6
7
1. Stop cock
2. Strainer
3. Pressure reducing valve
4. Non return valve
5. Expansion vessel
6. Expansion valve + tundish
7. Andrews bronze pump c/w ball valve unions (part no. B249)
8. Combined temperature and pressure relief valve + tundish
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
Hot Outlets
8
Andrews WH and WHX Multiple Water Heater Installation with ST Range Storage Cylinder, Quick Connect Cord Kit and Secondary Return
Fig No.11
Remote controller set to 70
ºC
Gas Supply
Pump (See Fig. No’s. 12/13)
Quick connect cord kit (part no. B286)
HWS flow
Storage cylinder
Tank thermostat kit (part
no. C927) set to 65ºC
Bronze secondary pump
Cold Supply NB. Size mains pressure group to suit building design flow rate
Gas rate for NG units
WH42 - 5.1 m
3
/hr
WH56, WHX56 - 6.5 m
3
/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m
3
/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1 2 3 4
5
6
7
1. Stop cock
2. Strainer
3. Pressure reducing valve
4. Non return valve
5. Expansion vessel
6. Expansion valve + tundish
7. Andrews bronze pump c/w ball valve unions (part no. B249)
8. Combined temperature and pressure relief valve + tundish
Hot Outlets
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
8
Andrews WH and WHX Multiple Water Heater Installation with ST Range Storage Cylinder and Secondary Return
Fig No.12
Gas Supply
HWS flow
Hot Outlets
Storage Cylinder
Tank thermostat kit (part
no. C927) set to 65ºC
Bronze secondary pump
Cold Supply NB. Size mains pressure group to suit building design flow rate
Gas rate for NG units
WH42 - 5.1 m3/hr WH56, WHX56 - 6.5 m3/hr
Gas rate for Propane units
LWH42 - 1.9 m3/hr LWH56, LWHX56 - 2.5 m3/hr
Dynamic Pressure
NG 20 mbar Propane 37 mbar
1 2 3 4
4
5
6
7
1. Stop cock
2. Strainer
3. Pressure reducing valve
4. Non return valve
5. Expansion vessel
6. Expansion valve + tundish
7. Andrews bronze pump c/w ball valve unions (part no. B249)
8. Combined temperature and pressure relief valve + tundish
When using multiple units in conjunction with a storage vessel the full output of all heaters is required to provide maximum recovery volume. In this case the primary pump must be sized to give 8 litres/min for each heater. See Fig No’s. 12 and 13.
Pump (See Fig. No’s. 12/13)
Remote controller kit (part no B285)*
*An Electronic System
Controller Kit can be used as an alternative when manifolding up to six units. (see Fig. No’s 6 and 8)
Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details
6
8
Flow Rate Head Loss and Pump Sizing
Fig No.13
The WH and WHX units will operate within a water inlet pressure range from 1.0 bar to 10.0 bar. When a pump is used with a storagae system or for secondary return circulation only bronze or stainless steel pumps must be used.
The pump must be sized to give a minimum flow rate of 8 L/min through each heater.
The head loss through the FASTflo range of products is due to the friction generated when the water flows through the heat exchanger and associated components.
Water Flow (litres/minute)
Head Loss (bar)
0
2.5
2
1.5
1
0.5
0
5
10 15 20
25 30
A suitable 3 speed bronze pump kit with ball valve unions to 28mm cu. can be supplied by Andrews, part no.B249 (see Fig No. 14)
Pump Selection using multiple heaters (pump required for first unit only)
Number of units Flow rate required Approximate head Speed setting
1 8 l/min - 0.13 l/sec 50 kPa 2
Pump selection using multiple heaters (flow through all units)
2 16 l/min - 0.27 l/sec 50 kPa 2
3 24 l/min - 0.40 l/sec 60 kPa 3
4 32 l/min - 0.53 l/sec 60 kPa 3
5 48 l/min - 0.67 l/sec 60 kPa 3
6 48 l/min - 0.80 l/sec 60 kPa 3
Pump Curves for Andrews 3 Speed Bronze Circulating Pump. Part No.B249
Fig No.14
0
P1
(W)
200
0 0.2
1
160
120
80
40
0
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Q(1/s)
2
3
4
5
6
7
8
(m)
H
SPEED 3
SPEED 2
SPEED 1
Dimensions WH42/LWH42/WH56 and LWH56
Fig No.15
Dimensions WHX56 and LWHX56
Fig No.16
WH42, LWH42, WH56 and LWH56 Pre-assembled dual manifold unit dimensions
Fig No.17
WH42, LWH42, WH56 and LWH56 Pre-assembled triple manifold unit dimensions
Fig No.18
WHX56 and LWHX56 Pre-assembled dual manifold unit dimensions
Fig No.19
Note: Pipework covers are optional
WHX56 and LWHX56 Pre-assembled triple manifold unit dimensions
Fig No.20
Note: Pipework covers are optional