FastenMaster LedgerLOK User Manual

Faster, Easier, Stronger than 1⁄2" lags.
The fi rst fastener engineered to attach deck ledger boards to a wooden house structure with no predrilling.
Stronger design shear values than 1⁄2" lags
IBC/IRC code compliant. ESR# 1078
Built-in washer head design eliminates the need for additional washer
Proprietary three-step coating process protects against corrosion, even in pressure treated wood. ACQ approved
Free 5⁄16" driver bit in every package
Note: Not designed for use in masonry or concrete
Photograph should not be used as a reference for fastening patterns.
For more information or free samples, call FastenMaster at 800.518.3569.
FASTENMASTER, 153 BOWLES ROAD, AGAWAM, MA 01001 WWW.FASTENMASTER.COM
INSTALLATION PROCEDURE
LedgerLok should be installed using a high torque, 1⁄2" variable speed drill (at least 18V if cordless). Choose the proper length LedgerLok so that threads fully engage the main member (i.e., rim joist). Bring washer ush to side member – do not countersink.
Lateral Design Values (in pounds per Fastener)
for single shear connections loaded perpendicular to grain
Nails Lags
16D 20D
3
8"
1
2"
Wood
Specic Gravity**
FastenMaster
LedgerLok
Red Oak 0.67 373 184 222 160 280 Southern Pine 0.55 290 154 185 140 230 Doug. Fir-L, SCL* 0.50 255 141 170 130 200 Doug. Fir-S 0.46 233 131 157 120 190 Hem. Fir 0.43 216 122 147 120 180 E. Spruce, W. Cedar 0.36 179 104 126 100 150
PRODUCT FEATURES
5
16" HEX
WITH OVERSIZED
WASHER HEAD
MADE OF HEAT
TREATED STEEL FOR
DRAMATICALLY
INCREASED
STRENGTH AND
DRIVABILITY
* SCL=Structural Composite Lumber (LVL,PSL and LSL)
Wood species identied typically have average specic gravity similar to the values shown on this table.
**
All design values based on 11⁄2" side member thickness and penetration into main member as follows: LedgerLok 2", Nails 10x diameter, Lags 8x diameter. Design values may be subject to adjustment factors (section 10.3 in NDS) based on conditions existing during installation as well as those expected during service life.
The lag screw and nail design values included in these tables are compiled directly from the 2005 National Design Specication for Wood Construction (2005 NDS).
For correct fastening patterns and complete installation procedures when attaching the deck ledger to rim joist, consult our Deck Ledger to Rim Joist Technical Bulletin at www.FastenMaster.com. In some ledger board connections, LedgerLok may not be a one-to-one replacement for
For use of LedgerLok in non-ledger applications, please consult a design professional for designing all connections, which include the number and location of all fasteners to meet the national and local code requirements.
Ledger Board Attachment Comparative Data
The statement “Faster, Easier, Stronger than values in ICC-ES Report #1078 and
For complete design values and engineering data, available through ICC-ES, see report ESR #1078 at www.icc-es.org.
For technical assistance or questions regarding proper use of this fastener, please contact FastenMaster Technical Support at 800.518.3569 or visit www.FastenMaster.com.
1
2" lag screws” refers to the comparison of LedgerLok design
1
2" lag screws as published in the current NDS.
1
2" lag screw patterns.
Item # Screw Length Quantity per Pack
FMLL358-12 35⁄8" 12
FMLL005-12 5" 12
FMLL358-50 3
FMLL005-50 5" 50
FMLL358-250 3
FMLL005-250 5" 250
FMLLSHEET (0211)
5
8" 50
5
8" 250
MULTI-COATED
FOR GUARANTEED
CORROSION
PROTECTION.
ACQ APPROVED
SUPER-SIZED
THREADS FOR
INCREASED HOLDING
POWER
GIMLET POINT FOR
FAST DRILLING
FASTENMASTER, INC., 153 BOWLES ROAD, AGAWAM, MA 01001
800.518.3569 WWW.FASTENMASTER.COM
FastenMaster® and LedgerLok® are trademarks of OMG, Inc. Copyright
©
2011 OMG, Inc. All rights reserved.