Faster, Easier, Stronger
than 1⁄2" lags.
The fi rst fastener engineered
to attach deck ledger boards
to a wooden house structure
with no predrilling.
•
Stronger design shear
values than 1⁄2" lags
•
IBC/IRC code compliant.
ESR# 1078
•
Built-in washer head design
eliminates the need for
additional washer
•
Proprietary three-step coating
process protects against
corrosion, even in pressure
treated wood. ACQ approved
•
Free 5⁄16" driver bit in
every package
Note: Not designed for use in
masonry or concrete
Photograph should not be used as a reference for
fastening patterns.
For more information or free samples,
call FastenMaster at 800.518.3569.
FASTENMASTER, 153 BOWLES ROAD, AGAWAM, MA 01001 WWW.FASTENMASTER.COM
INSTALLATION PROCEDURE
LedgerLok should be installed using a high torque, 1⁄2" variable speed drill (at least 18V if cordless).
Choose the proper length LedgerLok so that threads fully engage the main member (i.e., rim joist). Bring
washer ush to side member – do not countersink.
Lateral Design Values (in pounds per Fastener)
for single shear connections loaded perpendicular to grain
Nails Lags
16D 20D
3
⁄8"
1
⁄2"
Wood
Specic
Gravity**
FastenMaster
LedgerLok
Red Oak 0.67 373 184 222 160 280
Southern Pine 0.55 290 154 185 140 230
Doug. Fir-L, SCL* 0.50 255 141 170 130 200
Doug. Fir-S 0.46 233 131 157 120 190
Hem. Fir 0.43 216 122 147 120 180
E. Spruce, W. Cedar 0.36 179 104 126 100 150
PRODUCT FEATURES
5
⁄16" HEX
WITH OVERSIZED
WASHER HEAD
MADE OF HEAT
TREATED STEEL FOR
DRAMATICALLY
INCREASED
STRENGTH AND
DRIVABILITY
* SCL=Structural Composite Lumber (LVL,PSL and LSL)
Wood species identied typically have average specic gravity similar to the values shown on this table.
**
All design values based on 11⁄2" side member thickness and penetration into main member as follows:
LedgerLok 2", Nails 10x diameter, Lags 8x diameter. Design values may be subject to adjustment factors
(section 10.3 in NDS) based on conditions existing during installation as well as those expected during
service life.
The lag screw and nail design values included in these tables are compiled directly from the 2005
National Design Specication for Wood Construction (2005 NDS).
For correct fastening patterns and complete installation procedures when attaching the deck ledger to
rim joist, consult our Deck Ledger to Rim Joist Technical Bulletin at www.FastenMaster.com. In some ledger
board connections, LedgerLok may not be a one-to-one replacement for
For use of LedgerLok in non-ledger applications, please consult a design professional for designing all
connections, which include the number and location of all fasteners to meet the national and local code
requirements.
Ledger Board Attachment Comparative Data
The statement “Faster, Easier, Stronger than
values in ICC-ES Report #1078 and
For complete design values and engineering data, available through ICC-ES, see report
ESR #1078 at www.icc-es.org.
For technical assistance or questions regarding proper use of this fastener, please contact FastenMaster
Technical Support at 800.518.3569 or visit www.FastenMaster.com.
1
⁄2" lag screws” refers to the comparison of LedgerLok design
1
⁄2" lag screws as published in the current NDS.
1
⁄2" lag screw patterns.
Item # Screw Length Quantity per Pack
FMLL358-12 35⁄8" 12
FMLL005-12 5" 12
FMLL358-50 3
FMLL005-50 5" 50
FMLL358-250 3
FMLL005-250 5" 250
FMLLSHEET (0211)
5
⁄8" 50
5
⁄8" 250
MULTI-COATED
FOR GUARANTEED
CORROSION
PROTECTION.
ACQ APPROVED
SUPER-SIZED
THREADS FOR
INCREASED HOLDING
POWER
GIMLET POINT FOR
FAST DRILLING
FASTENMASTER, INC., 153 BOWLES ROAD, AGAWAM, MA 01001
800.518.3569 WWW.FASTENMASTER.COM
FastenMaster® and LedgerLok® are trademarks of OMG, Inc. Copyright
©
2011 OMG, Inc. All rights reserved.