Fantech RIL-150SW, RIL-200SW, RIL-150T, RIL-200T Installation & Maintenance Instructions Manual

Installation (cont)...
2.5. Mount the base in the desired position using the fasteners supplied.
2.6. Replace the fan body in-between the spigots and tighten the two retaining clamps or clamp screws.
Fan Maintenance
3.1. Inspect the fan at least once every 12 months to ensure that the motor and fan blades are clean. Any build up of dust should be removed using a non-abrasive cleaner.
3.3. Bearings are of the ‘sealed for life’ type and will not need a detailed inspection.
Wiring Diagram
In-Line
Duct Mounted Fan
RIL-150SW
Contact Us
RIL-200SW
INSTALLATION & MAINTENANCE
INSTRUCTIONS
Part No: INST-RIL-SW 11/12
Specification
Dimensions
Model
RIL-150SW 112 60 100 80 295 147 200 225 236 2.7
RIL-200SW 124 94 108.5 100 302 198 217 235 265 4.9
Model
RIL-150SW HIGH ( II ) 2500 0.22 50 LOW ( I ) 1950 0.19 44
RIL-200SW HIGH ( II ) 2500 0.50 120 LOW ( I ) 2000 0.45 100
A B C D E F G H J
Electrical
Speed Speed r/min
FLC Amps Input W
Data
To select high or low speed, switch the speed selector fitted to the side of the unit’s junction box to either “II” for high speed or “I” for low speed.
Weight
kg
1.5 This product is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for their safety. Children should be supervised to ensure that they do not play with the product.
1.6 Precautions must be taken to avoid back-flow of gases into the room from the open flue of gas or other fuel burning appliances.
1.7 A minimum of one (1) metre of duct is to be fitted to the fan inlet and discharge spigots.
1.8 To avoid a hazard, a damaged supply cord must be replaced by the manufacturer.
Installation
Warning: The fan must be isolated from the power supply during installation and maintenance.
2.1. Upon receipt, the fan should be inspected for any damage.
2.2. Check the details on the rating plate to ensure that the correct power supply is available
2.3. Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring regulations.
2.4. Remove the fan body from the spigots that are attached to the base by releasing the two retaining clamps (RIL-150SW, see diagram), or the two clamp screws (RIL-200SW).
General
1.1. It is important that these Installation and Maintenance Instructions are fully adhered to.
1.2. All electrical installations must be carried out by a suitably qualified and competent personnel in accordance with all statutory requirements.
1.3. The fan is designed for use in an ambient temperature of up to 40°C. It is not suitable for corrosive or explosive atmospheres.
1.4. The installer should provide easy access to the fan to facilitate future
maintenance, and ensure that the fan is adequately supported.
Loading...