Fanimation The Odyn FPD8148, Odyn FPD8149BN Owner's Manual

Model No. FPD8148**
OWNER'S MANUAL
READ AND SAVE THESE INSTRUCTIONS
Ceiling Fan
Net Weight 32.14 lbs (14.58 kg)
The Odyn
Important Safety Instructions
WARNING: To avoid fire, shock and serious personal injury, follow these instructions.
1. Read your owner’s manual and safety information before installing your new fan. Review the accompanying assembly diagrams.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not insert anything into the fan blades while the fan is operating.
Additional Safety Instructions
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The fan base must be securely mounted and capable of reliably supporting at least 35 lbs. (fan and accessories not to exceed 35 lbs. or 15.88 kgs.). See page 5 of owner’s manual for support requirements. Consult a qualified electrician if in doubt.
4. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
5. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not have adequate electrical knowledge or experience, have your fan installed by licensed electrician.
6. Suitable for use with solid-state speed controls.
WARNING
:
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS FAN MUST BE INSTALLED WITH A GENERAL USE,
ISOLATING WALL CONTROL/SWITCH.
WARNING
:
This product is designed to use only those parts supplied with this product and/or accessories designated specifically for use with this product. Using parts and/or accessories not designated for use with this product could result in personal injury or property damage.
WARNING
:
To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the
WARNING
:
Mount to an outlet box marked acceptable for fan support.
brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
LIMITED LIFETIME WARRANTY
Extends to the original purchaser of a Fanimation Fan
1. LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship
during the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned to our national service center. Proof of purchase is required. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement.
2. ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due
to defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center. Purchaser will be responsible for labor charges after this one-year period. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement.
3. If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or
workmanship, we will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.
4. Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting,
corroding, tarnishing, or peeling.
5. This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to
extremes of heat or humidity, or as a result of any modification to the original product.
6. All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that
sold the fan or Fanimation.
7. Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this
warranty.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. If the intentional radiator can be classified as a Class B digital device or a PC peripheral, then shall include the following or equivalent: Note: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Note: For a Class A digital device, statements of 15. 105(a) must be included when appropriate for the device in question.
5. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be
supervised to ensure that they do not play with the appliance.
7. For supply connections, if the conductor of a fan is identified as a grounded conductor, then it should be connected to a grounded conductor power supply. If the conductor of a fan is identified as an ungrounded conductor, then it should be connected to an ungrounded conductor power supply. If the conductor of a fan is identified for equipment grounding, then it should be connected to an equipment-grounding conductor.
LIMITED LIFETIME WARRANTY
Extends to the original purchaser of a Fanimation Fan
9. It is understood that any repair or replacement is the exclusive remedy available from Fanimation. There is no other
expressed or implied warranty. Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law. Some states do not allow limitations on implied warranties. Fanimation will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, except as may otherwise be accorded by law. This warranty gives you special legal rights and you may also have other rights that vary from state to state.
10.A certain amount of wobble is normal and should not be considered a problem or a defect.
Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Energy Efficient Use of Ceiling Fans . . . . . . . . . . . . . . . . . . . . .5
Electrical and Structural Requirements . . . . . . . . . . . . . . . . . .5
How to Assemble Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . .7
How to Hang Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . .9
How to Wire Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . 10
How to Install Your Canopy Housing . . . . . . . . . . . . . . . . . . . 11
How to Assemble the Ceiling Fan Blades . . . . . . . . . . . . . . . .
How to Assemble Your Light Kit Assembly or Cap. . . . . . . .
How to Operate Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . .13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
How to Clean Your Ceiling Fan Blades. . . . . . . . . . . . . . . . . . .13
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Exploded-View Illustration . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Table of Contents
8. Under no circumstances may a fan be returned without prior authorization from Fanimation. The receipt of purchase must
accompany authorized returns and must be sent freight prepaid to Fanimation. The fan to be returned must be properly packed to avoid damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.
.12
11
1. Check to see that you have received the following parts:
NOTE:
If you are uncertain of part descri ption, refer to
exploded view illustration.
4
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
Do not install or use fan if any part is damaged or missing. This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Fanimation. Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage.
 )an 0otor $ssePEly  +anger %racket $ssePEly  'ownrod+anger %all $ssePEly  Ceiling Canopy  Canopy 6crew Cover $ssePEly  0otor Coupling Cover $ssePEly  %lade Cover 6et  %lade +older 6et
 %lade 6et  /ight 3late $ssePEly  /(' $ssePEly  6teel Cap $ssePEly  *lass 
+and +eld 5ePote
+ardware Eags:
– 7wentyeight Ý [  PP
Elade to Elade holder 3an +ead 6errated 6crew
– 1ineteen Ý [  PP
Elade holder to Potor 3an +ead 6crew
– 3hillips 6crewdriver Ý – )our :ire Connectors – %alance .it
Ceiling Canopy
Hanger Bracket
Assembly
Downrod/ Hanger Ball Assembly
Motor Coupling
Cover Assembly
Fan Motor Assembly
Hardware Bag
Hand Held Remote
Glass
Steel Cap Assembly
Blade Holder Set
Blade Set
Blade Cover Set
Canopy Screw Cover Assembly
Light Plate Assembly
%ag $ssePEly 6afety CaEle
This manual is designed to make it as easy as possible for you to assemble,
install, operate and maintain your ceiling fan
Tools Needed for Assembly
2ne 3hillips head screwdriver
One stepladder
7hree wire connectors supplied
,nstalled :ire /ength
:ire 6i]e $:*/
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 10). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
One wire stripper
8p to  ft
 ft

One ´ Elade screwdriver
Materials
:iring outlet Eo[ and Eo[ connectors Pust Ee of type reTuired Ey the local code 7he PiniPuP wire would Ee a conductor wire with ground of the following si]e:
NOTE:
Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing contact your local retailer.
LED Assembly
5
Energy Efficient Use of Ceiling Fans
Ceiling fan performance and energy savings rely heavily on theproperinstallation and use of the ceiling fan. Here are a few tips to ensure efficient product performance.
Choosing the Appropriate Mounting Location
Ceiling fans should be installed, or mounted, in the middle of the room and at least 7 feet above the floor and 18 inches from the walls. If ceiling height allows, install the fan 8 - 9 feet above the floor for optimal airflow. Consult your Fanimation Retailer for optional mounting accessories.
Turn Off When Not in the Room
Ceiling fans cool people, not rooms. If the room is unoccupied, turn off the ceiling fan to save energy.
Using the Ceiling Fan Year Round Summer Season: Use the ceiling fan in the counter-
clockwise direction. The airflow produced by the ceiling fan creates a wind-chill effect, making you “feel” cooler. Select a fan speed that provides a comfortable breeze, lower speeds consume less energy. WinterSeason:Reverse the motor and operate the ceiling fan at low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down into the occupied space.Remember to adjust your thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step!
Electrical and Structural Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 HZ, 15 Amp Circuit. Electrical code requires use of a fan-rated outlet box to support the extra weight and motion associated with a ceiling fan. A fan-rated box will be labeled as such and typically supports up to a 70lb ceiling fan. Fan-Rated Outlet Boxes vary in ratings and design. Ensure the ratings of your ceiling fan outlet box meet the requirements for the ceiling fan being installed. Figure 1, Figure 2 and Figure 3 depicts different structural configurations that may be used for mounting the outlet box.
Low profile usage diagram idea (Figure 1)
A 1»2-in.-deep pancake box is meant to be screwed to a joist or block. It’s used if only one cable is coming into the box. It is also available in a saddle-mount configuration.
CEILING
2" x 4"
CEILING JOIST
OUTLET BOX
Figure 1
Figure 2
2" x 4"
CEILING JOIST
CEILING
OUTLET BOX
Deeper profile usage diagram idea (Figure 2)
A 2-1»-in.-deep box can be attached to blocking between joists and is roomy enough to handle more than one cable.
6
Electrical and Structural Requirements (Continued)
If your fan is to replace an existing light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National an d Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marke d acceptable for fan support of 15.88 kg (35 lbs) or less. Use screws supplied with outlet box. Most outle t boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
No blocking (Figure 3)
Paired with a deep box, this hanger is meant to span between two joists and takes the place of wooden blocking.
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
Figure 3
CEILING JOIST
CEILING
OUTLET BOX
7
How to Assemble Your Ceiling Fan
1. Remove the hanger ball portion from the downrod/ hanger ball assembly by loosening the set screw in the hanger ball until the ball falls freely down the downrod. Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstal­lation in Step 6. (Figure 1)
Downrod
Set Screws (2)
Downrod
Black, White and safety cable wires
Set Screw
Pin
Hanger Ball
Figure 1
Figure 2
Figure 3
3. Loosen the two set screws in the downrod support
of the motor assembly. Route the black, white and safety cable wires through the downrod. (Figure 3)
4. Slide downrod into the downrod support on top of the motor. Install the clevis pin by aligning the holes in the downrod support with holes in the downrod. Secure clevis pin with hairpin clip. Tighten the two set screws with nuts in the downrod support. (Figure 4)
WARNING
It is critical that the clevis pin in the downrod support is properly installed and the set screws and nuts are securely tightened. Failure to do so could result in the fan falling.
2. Remove the hairpin clip and clevis pin from the
bottom of the downrod. Retain the pin and clip for reinstallation in Step 4. (Figure 2)
Hairpin Clip
Clevis Pin
Downrod
Set Screws and
Locking Nuts (2)
Hairpin Clip
Clevis Pin
Figure 4
Figure 5
5. Route wires through Motor Coupling Cover, Canopy
Screw Cover and Ceiling Canopy. (Figure 5)
Motor Coupling Cover
Ceiling Canopy
Canopy Screw Cover
8
How to Assemble Your Ceiling Fan (continued)
7. Cut off excess lead wire approximately 6 to 9 inches above top of the top of the downrod. Strip insulation off 1/2 inch from the end of each lead wire. (Figure 7)
NOTE:
All set screws must be checked, and retightened
where necessary, before installation.
6. Reinstall the hanger ball on the downrod as follows. Route the two 80 in. wires and safety cable through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin. Securely tighten the set screw in the hanger ball. A loose set screw could create fan wobble. (Figure 6)
Figure 6
Figure 7
9
How to Hang Your Ceiling Fan
NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advise, as it must be grounded for safe operation.
WARNING
The fan must be hung with at least 7’ of clearance from ƀoor to blades. (Figure 2)
WARNING
To avoid possible ſre or shock, be sure electricity is turned off at the main fuse box before hanging. (Figure 1)
1. Securely attach the hanger bracket to the outlet box using the outlet box screws and washers supplied with the outlet box. (Figure 3)
2. Drill a ¼” pilot hole into the building structure to prevent splitting or cracking with installation of the lag
bolt. Using the
” x 2” lag bolt and at washer, attach safety cable to ceiling joist or wood structural member. The lag bolt will pass through the at washer, safety cable loop, and into the building structure. (Figure 3)
NOTE: Ceiling support cable cannot be secured to
junction box only, it must be directly secured to ceiling joist or structural member using the
” x 2” lag bolt
CPFƀCVYCUJGT(KIWTG
3. Make sure the electrical supply wires, including the hanger bracket grounding wire and safety cable are pulled through the downrod, between the hanger
bracket and the junction box so that electrical connections can be made later.
Figure 2
CEILING
FLOOR
NO LESS
THAN
7 FEET
Figure 1
MAIN FUSE BOX
WOOD MEMBER (2” X 4” APPROX.)
CEILING JOIST
CEILING
JUNCTION
BOX
HANGER BRACKET
CEILING SUPPORT
CABLE
Figure 3
WARNING
The outlet box must be securely anchored. Hanger bracket must seat ſrmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and /or outlet box are not securely attached, the fan could wobble or fall.
4. Carefully lift the fan and seat the downrod/hanger ball assembly on the hanger bracket that was just attached to the outlet box. Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 4)
WARNING
Failure to seat tab in groove coul d cause damag e to electrical wires and possible shock or ſre hazard.
WARNING
To avoid possible shock, do not pinch wires between the hanger ball assembly and the hanger bracket.
5. Attach the safety cable to ceiling support cable. Slide cable clamp and washer onto safety cable (from fan). Place the end of cable through the loop of ceiling support cable. Pull as much cable through loop as possible. Feed end of cable into clamp hole and rmly tighten screw (Figure 4).
X 1
X1
HARDWARE USED:
Figure 4
TAB
NOTE: SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY
DOWNROD/HANGER BALL ASSEMBLY
ATTACH SAFETY CABLE TO CEILING SUPPORT CABLE
CEILING SUPPORT CABLE CLAMP W/SCREW
FLAT WASHER Ø14 x Ø 5 x 1 mm
10
How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before hanging (Figure 1).
WARNING
MAIN FUSE BOX
Figure 1
NOTE:
If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
Figure 2
1. Connect the green grounding lead from the
downrod/hanger ball assembly and the green grounding lead from the hanger bracket to the supply
grounding conductor (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors. Securely connect the white fan motor wire to the white supply (neutral) wire using wire connector. Securely connect the black fan motor wire to the black supply wire using wire connector (Figure 2).
Green Wire from Supply (Ground)
White Wire from Supply
White Wire from Fan
Green Wire from Hanger Bracket (Ground)
Green Wire from Hanger Ball (Ground)
Listed Outlet Box
Household Supply
Black Wire from Supply
Black Wire from Fan
x 3WIRE
CONNECTORS
HARDWARE USED:
NOTE:
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors except for the ground wire. Do not operate fan until the blades are in place. Noise and motor damage could result.
WARNING
Figure 3
Green Wire from Supply (Ground)
White Wire from Supply
White Wire from Fan
Green Wire from Hanger Bracket (Ground)
Green Wire from Hanger Ball (Ground)
Listed Outlet Box
Household Supply
Black Wire from Supply
Black Wire from Fan
2. After connections have been made, turn leads
upward and carefully push leads into the outlet box, with the white and green leads to one side of the box and the black leads toward the other side. (Figure 3)
11
How to Install Your Canopy Housing
2. Securely attach and tighten the canopy screw cover
over the shoulder screws in the hanger bracket utilizing the keyslot twist-lock feature. (Figrue 2)
1. Remove one of the two shoulder screws in the hanger bracket. Loosen the second shoulder screw without fully removing it. Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket. Tighten shoulder screw. Fully assemble and tighten second shoulder screw that was previously removed. (Figure 1)
WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the canopy housing and not pinched between the housing and the ceiling.
NOTE: This step is applicable after the neccessary wiring is completed.
Canopy Screw Cover
How to Assemble the Ceiling Fan Blades
Do not connect fan blades until the fan is completely installed. Installing the fan with blades assembled may result in damage to the fan blades.
CAUTION
HARDWARE USED:
x 18
1/4˝-20 x 11 mm
Pan Head Screw
NOTE: Periodically check blade holder hardware and
resecure if necessary.
2. Secure the blade holders to the flywheel using the 1/4Ý-20 x 11 mm screws through the holes located on the bottom of the flywheel. (Figure 2)
To reduce the risk of personal injury, do not bend the blade holders when installing, balancing the blades or cleaning the fan. Do not insert foreign objects in between the rotating blades.
WARNING
!
To reduce the risk of electric shock, disconnect the electrical supply circult to the fan before installing light kit.
CAUTION
x 273/16˝-24 X 13 mm Pan Head Serrated Screw
HARDWARE USED:
Figure 2
Blade Holder
1/4Ý-20 x 11 mm Pan Head Screw
(2 per assembly)
1. Lay flat side of blade holder on a flat surface with the inside of the blade holder arm facing up. This is the side with the threaded posts and pitched foot. Position the blade over the blade holder with the threaded posts showing. Make sure the bottom edge of the blade is fully seated against the blade holder. Place blade cover on top of the blade, positioning the holes over the threaded posts. With a Phillips screwdriver, thread three screws into the posts but do not fully tighten.Prior to final tightening, position the centerline of the blade holder with the center of the end of the blade. Tighten three screws to secure the blade. (Figure 1)
Figure 2
Ceiling Canopy
Figure 1
Figure 1
3/16Ý-24 x 13 mm Pan Head Serrated Screw (3 each per blade)
Blade
Blade Cover
Blade Holder
12
How to Assemble Your Light Kit Assembly or Cap
1. Remove one of the three screws in the support bracket at the bottom of the motor assembly. Slightly loosen the remaining two screws. Assemble the light plate assembly to the support bracket using the two key slots in the socket plate. Replace the third screw and securely tighten all three screws. (Figure 1)
LED Assembly
Glass
Steel Cap Assembly
2 (Option A--for use with light kit)
Connect the 2 single-pin connectors from the LED assembly to the 2 single-pin connectors from motor assembly. (Figure 2A)
2 (Option B--for use with steel cap)
If you want to install the steel cap and not the light kit. Assemble the steel cap to the light plate assembly by twisting in a clockwise direction. (Figure 2B)
Light Plate Assembly
Light Plate Assembly
Light Plate Assembly
SCREWS (3)
Figure 1
Figure 4
Figure 2A Figure 2B
To reduce the risk of electric shock, disconnect the electrical supply circult to the fan before installing light kit.
CAUTION
NOTE:
If you have installed your fan with the steel cap,
skip steps 3 and 4.
LED Assembly
Light Plate Assembly
Figure 3
3. Remove three screws in the light plate assembly.
Assemble the LED assembly to the light plate assembly using the two key slots. Replace the third screw and securely tighten all three screws. (Figure 3)
4. Secure the glass to light plate assembly by twisting in a clockwise direction. Do not over-tighten. (Figure 4)
The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair.
CAUTION
Loading...
+ 26 hidden pages