TW40 Wall Control
SPECIFICATION and INSTRUCTION SHEET
DESCRIPTION: One DC Motor Ceiling Fan and Light, 6 Speed, Reversing Remote Control
FAN MODEL USED: See Catalog or visit our website www.fanimation.com for more
information
How to Wire and Operate Your TW40 Wall Control
NOTE: If fan or supply wires are different colors than indicated,
have this unit installed by a qualified electrician.
WARNING
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advise, as it must be
grounded for safe operation.
1. Installing Wall Control (Figure 1):
• With electrical power still disconnected, remove the
existing wall plate and switch.
• Make wiring connections with wire nuts as shown in
Figure 1.
– One black wire from wall control unit to black
(TO MOTOR L).
– One black wire from wall control unit to black wire
leading to ceiling outlet box.
– One green wire from wall control unit to ground wire
leading to ceiling outlet box.
• Attach wall control unit to outlet box using the two
#6-32-19mm screws provided. (Figure 2)
• Attach wall plate to the switch control and using the two
#6-32-9mm screws provided.
• Restore electrical power.
3.
To make fan operational, remove the top panel then install
23A/12V battery (included) in wall control, with fan power off.
Then follow the remote code setting process. (If not used for
long periods of time, remove battery to prevent damage to
transmitter). Store the remote away from excessive heat or
humidly (Figure 3).
4. Remote Control Setting and Speed (RPM) Setting
Process :
1. When powering on your fan, do not press any button(s)
before pressing the “SET” button, otherwise it will fail the
learn procedure. If you press a button before the “Set”
button, please turn the power off then on again, and start
the process again.
2. After installing the unit and restoring power to your fan,
press and hold the “SET” button 1~5 seconds. You must
press the “SET” button within 60 seconds of restoring
power to the fan.
3. The fan will start to run and begin the control setting
process.
4. DO NOT press any button(s) after pressing the SET
button and while the fan is programming or it will fail to
program. The fan will run in both directions for a total of
approximately 5 minutes.
5. When the fan stops after approximately 5 minutes the
control and speed setting process is complete.
BLACK (AC IN L)
)L N
ERIW
LORTNOC
LLAW
I C
A
( KCALB
D
NUORG
NEERG
BLACK (TO MOTOR L)
Check to see that all connections are tight, including ground,
and that no bare wire is visible at the wire connectors,
except for the ground wire. Do not operate fan until the
blades is in place. Noise and fan damage could result.
NOTE: If you want to change the blades: turn
the off→ change the blades →turn the power
on →replay the power setting process.
AC120V 60HZ
BLACK
KCALB
KCALB
BLACK WHITE
BARE
Figure 1
Figure 2
WARNING
Figure 3
INPUT
WHITE (AC IN N)
AC SUPPLY

5. The remote buttons instruct as below:
Fan speed:
I = minimum speed II = low speed
III = medium low speed IV = medium speed
V = medium high speed VI = high speed
Button:
This button turns the fan off.
Reverse button:
This button is to control fan direction.
Light button:
The button is to control light, Infinite light levels
are available by holding the light on/off button
(Figure 4).
6. “D” and “ON” dip switch:
The “ON” selection is the light dimmable selection and is
to be used with all bulbs other than CFL. The “D”
selection is the light on only (no dimming function) and
is to be used with CFL bulbs (as CFL bulbs cannot be
dimmed). The receiver provides the following protective
function: (Figure 5)
Lock position: The DC motor has a built-in safety feature
against blade obstruction against obstruction during
operation. If something obstructs the fan blades the
motor will stop operating after 30 seconds of
interruption. Please remove obstacles and reset.
Over 80W protection: When the receiver detects motor
power consumption which is greater than 80W, the
receiver power will shut down and fan operation will
cease. Disconnect the power supply and after 5
seconds return power on to the fan.
I I I
I I
I
Figure 4
Figure 5
IIV
V
V
10983 Bennett Parkway
Zionsville, IN 46077
(888) 567-2055 • FAX (866) 482-5215
Outside U.S. call (317) 733-4113
Visit Our Website @ www.fanimation.com
Copyright 2017 Fanimation
2017/08 V.01