family first FFP240VH2 Product Manual

FFP240VH2
240VAC 50 Hz, 40mA
PHOTOELECTRIC SMOKE ALARM
WITH 9 VOLT BATTERY BACKUP &
HUSH BUTTON
SUITABLE AS SINGLE (STAND ALONE) OR INTERLINKING (MULTI-STATION)
MAINS POWER
Operating voltage (Max.): 220-240VAC, 50Hz Operating current (Max.): 40mA
BACKUP BATTERY
Operating voltage (Max.): 9V DC Operating current (Max.): 20mA Battery type: 6F22
IMPORTANT: This manual contains important information about the installation and operation of your smoke alarm. Please read carefully before installation and keep for future reference. Please ensure that this leaflet remains in the household where the alarm is installed.
WARNING: This smoke alarm is designed to alert you to the presence of smoke. It cannot prevent a fire. There are hazards against which smoke alarms may not be effective such as smoking in bed, explosions, etc. The ultimate responsibility for fire protection rests with you. This responsibility includes escape planning, safety checks, and an effective warning system. In case of fire, a well placed, properly looked after smoke alarm may provide a few seconds so that you can escape and call the fire brigade.
LIMITATIONS: Loss of AC power will render this smoke alarm inoperative unless a 9V battery is installed in the unit. Never install a smoke detector where temperatures are less than 5oC or more than 45oC or above 90% relative humidity level. Never paint the smoke alarm. This smoke alarm has a service life of ten years under normal use. We recommend to replace it within no more than ten years to ensure maximum protection. A smoke detector is not a substitute for insurance. You should obtain and maintain insurance on your home and property.
WHERE TO INSTALL YOUR ALARM
For best safety, install smoke alarms in every room: Including hall, bedrooms, living rooms, attics & basement. At the very least, one smoke alarm on every floor.
PRODUCT MANUAL
BEDROOM
HALL
BEDROOM
LIVING ROOM
KITCHEN
BASEMENT
MULTI-STOREY RESIDENCE
KEY:
Minimum required smoke alarm locations
Recommended additional smoke alarm locations
Smoke alarms with hush features recommended for additional protection
DINING ROOM
LIVING ROOM
BEDROOM
BEDROOM
KITCHEN
SINGLE-STOREY RESIDENCE, APARTMENT, MOBILE HOME
N11518
SMOKE ALARM PLACEMENT
Typical single-storey home
Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area or hallway is more than 9 metres (30 feet) long, install a smoke alarm at each end. If there is a basement, install a smoke alarm on the basement ceiling at the bottom of the stairwell.
Typical Multi-storey or split level home
Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area or hallway is more than 9 metres (30ft) long, install a smoke alarm at each end. Please install a smoke alarm on the top of a first-to-second floor stairwell.
RECOMMENDED PLACEMENT OF SMOKE ALARMS
Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are operated in sleeping areas.
Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all the points in the room. Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, wall mounting on an inside partition is preferred to avoid the thermal barrier that may form in the ceiling.
IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION
1. Place as close as possible to the centre of the ceiling as possible or at least no closer than 300mm to any wall or corner.
DO NOT INSTALL SMOKE ALARMS
1. Areas near appliances or where normal combustion regularly occurs (near furnaces, hot water heaters).
2. In areas with high humidity, like bathrooms, near dishwashers or washing machines. Install at least 3 meters (10 feet) away from these areas.
3. Air returns or heating and cooling supply vents. Install at least 900mm (3 feet) away from these areas. The air could blow smoke away from the detector, interrupting it’s alarm.
4. In rooms where temperatures may fall below 5ºC or rise above 45ºC.
5. In extremely dusty, dirty, or insect-infested areas where loose particles interfere with smoke alarm operation.
WARNING: Incorrect orientation will result in a decrease in operational effectiveness.
INSTALLATION AND MOUNTING INFORMATION
IMPORTANT: This alarm must be installed by a
licensed electrician!
The smoke alarm will function correctly either as a stand-alone alarm or inter-connected.
All inter-connected smoke alarms must be supplied from a single power circuit.
DO NOT connect inter-connect wire to live or neutral.
DO NOT connect the smoke alarm to a circuit protected by a Residual Current Device.
Connect and power the smoke alarm with 220-240VAC only.
Solid wires with 1mm2 (or larger) cross-section area are recommended for power supply and inter-connection. Strip the live, neutral and inter-connect wires back to the length of 10mm. Connect the wires to the terminals in the wall mount and ensure the screws are fully tightened.
AS3786
Lic 20124
SAI Global
2. Install a smoke alarm in each room that is divided by a partial wall.
3. Install a smoke alarm in lived-in attics or attics which house electrical equipment like furnaces, air conditioners, or heaters.
300mm
Heat an d smoke
from fir e
Best here
Dead air s pace, Do Not i nstall here
Dead air s pace, Do Not in stall here
300mm minimum
500mm maximum
smoke alarm must
be located between
500 - 1500 of the apex
31 Dunlop Road Mulgrave Victoria 317 0 Ph 03 9538 9200 Fax 03 9538 9299 sales@masterdistributors.com.au www.masterdistributors.com.au
The colours of the wires are: live = brown, neutral = blue and inter-connect = white. The smoke alarms can be inter-connected as many as 12 units in series. Check the connections carefully before closing the junction box. Incorrect connection may damage the unit.
Your smoke alarm is designed for easy mounting on walls or ceilings. Ideally, this smoke alarm is designed for mounting on a standard flush box (84mm mounting centres). Place the mounting bracket on it and locate the screw holes of the flush box. Then attach the bracket directly onto it with the screws provided. Then, check the mounting firmly.
For mounting without standard flush box, place the mounting bracket on the wall or ceiling surface, and use a pencil to mark down two drill hole locations. Usually, the distance between two centres of the drill holes should be 84mm. For wooden surfaces, attach the bracket directly to it with the screws provided. For concrete surfaces or masonry, use drilling machines to drill these two holes onto the surface first. The sizes of the holes are around
5.5mm in diameter and 25-30mm deep. Insert two dowels into the drilled holes before attaching the bracket. Then, check the mounting firmly.
Insert a 9V DC battery. Fold the alarm to wall mount tightly. The alarm cannot be secured if the battery is not installed properly.
The green LED will then light up. Press the TEST button to check that the alarm works. Inter-connected alarms must also be checked. Do not leave installation until the alarms have been checked for correct operation.
During the power up of the unit, several ‘beep’ alarms may sound. This is normal operation for the unit.
WARNING: DO NOT CONNECT TO OTHER INCOMPATIBLE SMOKE ALARMS.
OPERATION, TESTING AND MANTENANCE
Operation
The smoke alarm is operating once the power is connected and turned on (the battery must also be installed). When products of combustion are sensed, the unit sounds a loud alarm which continues until the air is cleared.
False Alarm
Units with the ‘silence’ feature have the capability of temporarily reducing the sensitivity of the alarm circuit for approximately 8 minutes. This feature is to be used only when a known smoke alarm condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm is deactivated by pushing the hush button on the smoke alarm once. The smoke alarm will automatically reduce sensitivity and light up the red indicator for approximately 8 minutes to indicate that the alarm is in the temporary silent condition. It will reactivate after such 8 minutes and sound the alarm if particles of combustion are still present. The ‘silence’ feature may be used repeatedly until the air has cleared.
CAUTION: Before using the alarm’s ‘silence’ feature, identify the source of the smoke and be certain that safe conditions exist.
Testing
Test by pressing the test button on the smoke alarm cover for at least 4 seconds, until the alarm sounds. It activates the self-test program and the alarm sounds if all electronic circuitry, horn and battery are working. When any smoke alarm is tested, all inter-connected units should sound an alarm. It is highly recommended to test the alarm weekly to assure proper operation. In case of no alarm sounds on test, and/or the unit has a defective battery, and then try to replace the battery with a new one. You can also test the alarm by blowing smoke into the unit.
PLEASE DISPOSE OFF THE BAD OR DISCHARGED BATTERIES PROPERLY TO PROTECT OUR ENVIRONMENT.
Maintenance
The smoke alarm is virtually maintenance free. However, under dusty conditions, a vacuum hose may be used to clear dust through the side opening. It is recommended to clean the alarm monthly to keep best performance. Normally, the alarm can be operated up to 10 years without replacement. See the replacing date on the bottom of the alarm unit.
BATTERY REPLACEMENT
The power of this smoke alarm is backed up by one 9V DC battery. The battery should last for at least 1 year under normal operating conditions. The smoke alarm has a low battery indicator, an audible ‘chirp’. It will operate at 30-40 second intervals for a minimum of 7 days. Replace the battery when this indication occurs. Only the following 9V DC batteries (which are available at hardware or electronic parts stores) may be used for replacement.
Carbon-Zinc Type: Eveready #216; Gold Peak #1604P; Gold Peak #1604S; Gold Peak 1604G; Premisafe G6F22.
Alkaline Type: Eveready Energizer #522; Gold Peak #1604A; Duracell #MN1604; Hi-Watt #6LR61X.
Lithium Type: Ultralife U9VL-J; FDK CP-V9J; Gold Peak CR-V9.
CAUTION: Switch off smoke alarm before removing smoke alarm for battery replacement.
WHAT TO DO IN CASE OF A FIRE
If there is a fire in your home, the precautions described will increase your chance of escaping safely. The following rules should always be highlighted during fire drills so that they are remembered in the case of a real emergency.
Stay calm and think clearly about the pre-arranged escape plan.
Leaving the house as soon as possible following the planned escape route. Do not stop to collect personal belongings.
Check doors to see if they are hot. If the door is hot, do not open it - use another escape route.
Keep all doors and windows shut, only open as a means of escaping.
Smoke rises, so keep close to the floor - if necessary crawl.
Take short breaths and if possible, cover your mouth and nose with a wet cloth.
Make your way to the pre-arranged meeting point and call the fire brigade. Give your full name and address.
Never re-enter a burning house. For further information on fire safety and prevention, contact your local fire prevention officer.
WARNING: Do not try to disassemble this smoke alarm, as it may damage or impede the operation. No user serviceable parts inside. The warranty will become void if misuse or abuse is apparent. This 10 year warranty is also conidtional on this unit being installed by a licensed electrical contractor in accordance with local building codes.
10 YEAR WARRANTY
The smoke alarm is warranted to be free from defects in materials and workmanship for ten (10) years from the date of purchase and is not transferable under normal use. The warranty does not cover natural disasters such as fire, flood, hurricanes and tornadoes. The warranty only applies if the smoke alarm is installed by a licensed electrical contractor in accordance with local regulations, is used in the normal way and is serviced regularly. The warranty is also conditional on the smoke alarm not being modified or subject to attempted repairs or contamination. The warranty excludes the battery, incidental and consequential damages. Your statutory rights as a consumer are in no way compromised by this
warranty. Master Distributors Pty Ltd agrees to repair or replace, at it’s option, any defective smoke alarm provided it is returned personally or by prepaid delivery with a copy of proof of purchase. This warranty does not cover damages resulting from lack of reasonable care of the product. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Subject to those non-excluded rights and provisions and the above warranty, Master Distributors Pty Ltd will not be liable for injury to persons, damage to property, or for any direct or indirect or consequential damage as a result of negligence or fault on the part of Master Distributors Pty Ltd or it’s servants, agents, suppliers and contractors or otherwise arising out of or resulting from, wether directly or indirectly, the use, installation or maintenance of the smoke alarm and any warranties or representations are excluded unless given by Master Distributors Pty Ltd in writing. Please leave this document, or a copy, for the end user.