Falcon Pro-Lite LD32, Pro-Lite LD36, Pro-Lite LD35, Pro-Lite LD33, Pro-Lite LD38 Installation And Servicing Instrucnions

...
Installation and Servicing Instructions
for
LD32, LD33, LD35, LD36, LD38 and LD39 DRY BAINS MARIE
LD34, LD37 and LD43 WET BAINS MARIE
Important Installation Information
The installer must ensure that installation of the unit(s) is in conformity with regulations in force at the time. For the UK, particular attention requires to be paid to:-
The unit has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltage stated on the data plate.
WARNING: THIS APPLIANCE MUST BE EARTHED!
Preventive Maintenance Contract
In order to obtain maximum performance from the equipment, we would recommend that a maintenance contract be arranged with
AFE Serviceline.
Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation for this service will be provided upon request. Contact
AFE Serviceline
as detailed below
:-
Tel: 01438 363 000 Fax: 01438 369 900
Falcon Foodservice Equipment
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland. e-mail: info@afefalcon.com
T100330 Ref. 2
C = Countertop Unit B = Base Unit
F = Freestanding Unit S = Stand Mounting Unit
Power Ratings at 230V AC
Type Width Depth Height Vertical Clearance Side/Rear Cl. Power Rating Fuse Rating
LD32 Dry Bain Marie
Model
C 300mm 600mm 285mm 600mm 150mm 0.48kW 3 amp
LD33 Dry Bain Marie
C 300mm 600mm 285mm 600mm 150mm 0.48kW 3 amp
LD34 Wet Bain Marie
C 350mm 600mm 285mm 600mm 150mm 1kW 5 amp
LD35 Dry Bain Marie
C 450mm 600mm 285mm 600mm 150mm 0.75kW 5 amp
LD36 Dry Bain Marie
C 450mm 600mm 285mm 600mm 150mm 0.75kW 5 amp
LD37 Wet Bain Marie
C 450mm 600mm 285mm 600mm 150mm 1kW 5 amp
LD38 Dry Bain Marie
C 300mm 600mm 285mm 600mm 150mm 0.48kW 5 amp
LD39 Dry Bain Marie
C 600mm 600mm 285mm 600mm 150mm 0.75kW 5 amp
LD43 Wet Bain Marie
C 600mm 600mm 285mm 600mm 150mm 2kW 13 amp
Weight
12kg
12kg
15kg
13kg
13kg
18kg
12kg
14kg
20kg
Technical Installation Information Table
Note
* 13A Fuse Rating:
The unit must be protected by a 13 amp fuse if a 13 amp plug is used.
If another type of plug is used, a 15A fuse requires to be used in the plug,
adaptor or distribution board.