Falcon EFS 200, EFS 400, EFS 402 Installation And Operating Instructions Manual

EFS 200, EFS 400, EFS 402 FRYERS
Installation and Operating Instructions
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to -
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the Data Plate.
WARNING - THIS APPLIANCE MUST BE EARTHED
On completion of the installation these instructions should be left with the Engineer-in-Charge for reference during servicing. Further to this, The Users Instructions should be handed over to the User, having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be arranged with FALCON SERVICE LINE. Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation will be given upon request to the FALCON SERVICE LINE contact numbers below.
Falcon Catering Equipment Head Office and Works
PO Box 37, Foundry Loan, Larbert Stirlingshire, Scotland FK5 4PL
Service Line Contact
PHONE - 01438 751111 FAX - 01438 369900
1. Models and variants
Models EFS200 - Single Pan (200mm wide) EFS400 - Single Pan (400mm wide) EFS402 - Double Pan (400mm wide)
2. Technical Specifications
Model
Oil Capacity (minimum)
Oil Capacity (maximum)
Weight
EFS 200 7 litres 9 litres 34 kg EFS 400 15 litres 18 litres 49 kg EFS 402 2 x 7 litres 2 x 9 litres 52 kg
Cable Length - 2 metres (without plug)
Power Ratings
EFS 200 - 7.5 kW EFS 400 - 15 kW EFS 402 - 2 x 7.5 kW (15 kW)
Dimensions
Height ex factory: 900 mm By adjustment of the feet: 850 mm Spec. execution of feet: 800 mm (To place the fryer under the working suface)
3. Installing The Appliance
3.1 Free standing fryers
When installing the unit please observe the following instructions (refer to diagramm below):
a) Ensure that the fryer is level by means of the two feet with adjustable screws (27 mm fork wrench). To change the height from 900 mm to 850 mm or vice versa:
b) Minimum distances to be observed between the fryer and the wall or other units; at the rear: 30 mm.
c) The fryer should not rest on an inflammable surface. Observe the local security and building regulations.
d) The fryer position should be fixed. The castors are only intended to facilitate servicing or cleaning of the unit. When installing a fryer equipped with four castors, the two front castor brakes must be locked.
Warning
The EFS 200 model cannot be left without any form of permanent fixture and should be secured by means of the two plates supplied.
100 - 150
850 - 900
200
400
400
57
750
EFS 200 EFS 400
EFS 402
Flat plate for Variants 1 and 2
Perforation for folding to 90
0
Angular plate for
variants 3 and 4
Adjustment of height:
- Lift of lay down fryer
- Unscrew screws
- Adjust to desired height
- Put back screws and tighten
900 (Standard height)
850
Various Fixing Methods:
1 - From one fryer to another (view from the back) 2 - To a kitchen cupboard (view from the back) 3 - To the wall (view from top) 4 - To the floor
4. Electrical connection
Connection and initial unit start-up should be carried out by a qualified person who can ensure that the installation meets the required standards.
Proceed as follows:
a) Check if the specification of the electrical mains corresponds to the information given on the data plate located on the control panel inside the door.
b) Connect according to IEC or CEI 335-1 standards and local regulations, i.e.:
Fit a mains plug to the connection cable which corresponds to the power of the rated current. Plug into the mains socket. For permanent installation: connect to a main switch with all the poles isolated; minimum distance of the contacts: 3 mm. The connection cable should at least be an H05RN-F type.
Fuse Sizes
* denotes 2 cables ** denotes 1 cable
5. Control Elements
1 Switch / temperature selector 0 - 190°C 2 Fat melting cycle. Temperature up to 100°C
machine in operation » 4 Light « overheating » Oiltemperatur >215ºC 5 Light « fat melting cycle » and stand-by position 6 Light « heater operating » 7 Startbutton for the pump ( Option )
Model EFS 200 EFS 400 EFS 402 Rating 7.5 kW 15 kW 2 x 7.5 kW
Supply Fuse
3N˜400 16A
3N˜400 25A
3N˜400
16A*/25A** Supply Fuse
3N˜230 20A
3N˜230 40A
3N˜230
20A*/40A**
cupboard
1
2
3
4
bend to ''L''
1 2
3 4
5
L1L2L3NPE
4.1 System of Connection
a) Normal power supply: 3NAC 400V, 50Hz 3L+N+PE
1 2
3 4
5
L1 L2 L3
PE
1 2
3 4
5
L1 L2 L3
PE
b) Special power supplies 3AC 400V, 50Hz, 3L+PE
3AC 230V, 3L+PE
AC 230V, L+N+PE
1 2
3 4
5
L1L2L3NPE
0
140°
150°
160°
180°
170°
190°
1
2
3
4
5