The information contained herein is the property of FALCON® ELECTRIC. This information is proprietary,
confidential, and not to be disclosed, disseminated or used except for the purpose provided by
FALCON®Electric, Inc.
OM 48009 D9/03
TABLE OF CONTENTS
Important Safety Instructions(READ FIRST)..1
Chapter 1.
ED Series UPS Overview....2
Model Cross Reference Table....2
Block Diagram......3
Selection Guide......4
Chapter 2.
Installation ......5
Inspecting the Equipment....5
UPS Setup .......5
Chapter 3.
Controls, Displays & Functions ...6
Front Panel Diagram & Description...6
Front Panel LED Functions....6
Rear Panel Diagram & Description...7
Chapter 4.
Communications Interface....8
Signals & Interfacing.....8
Chapter 5.
Operation......9
Step By Step Operating Procedure...9
Operational Mode Table .....10
Chapter 6.
Maintenance & Technical Support..11
Care & Maintenance.....11
Battery Life vs. Temperature....11
Battery Replacement.....11
Storing the UPS and Batteries ....12
FCC Considerations.....12
Technical Support & RMA Procedure ...13
Requesting Technical Information or Support..13
FALCON Web Support.....13
Warranty........14
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions which must be followed during the
installation, operation and maintenance of this UPS and its batteries. Please read all
instructions before operating this equipment and save this manual for future
reference.
CAUTION
All of the models presented herein are designed for installation and use in a
controlled environment free of contamination.
CAUTION
This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble.
This unit contains no user replaceable parts. Refer all servicing to Falcon Electric,
Inc.
CAUTION
This UPS is not intended to be used in conjunction with life support or operating
room equipment.
CAUTION
Always unplug this UPS prior to cleaning and never apply liquid or spray detergent
on the UPS.
CAUTION
Never attempt to service batteries. High voltage exists within the unit, which could
cause electrical shock. Servicing of batteries should be performed or supervised
by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing the UPS batteries, use the
same number and type of batteries.
IMPORTANT
Allow at least 24 hours, after the UPS is first installed and turned on, to fully charge
the internal battery and assure the maximum backup time is available.
DO NOT
DO NOT plug this UPS into its own output as this may damage the UPS.
DO NOT remove or unplug the input cord when the UPS is turned on. This
removes the safety ground from the UPS and the equipment connected to the UPS.
This UPS contains its own energy source (batteries). The output receptacles
may carry live voltage even when the UPS is not connected to an AC source.
CAUTION
1
ED Series UPS - Overview
Congratulations! You have selected the highest quality protection for your
computer today. The FALCON®ED Series UPS offers a quiet and compact
package with superior performance you can depend on. You now own a
member of the ED family which is a proud part of the very reliable and versatile
FALCON®products.
This User’s Guide is provided with your new ED unit. It will enhance your
understanding of the product and its functions. Read this handbook carefully in
the order it is presented prior to operating your unit. This will save you time and
effort in your installation and application. The illustrations will also familiarize
you with the ED's operating modes and indications. Always operate the unit
within the guidelines and specifications given to maximize the unit's efficiency
and lifetime. Also, your understanding of the product is essential in providing
you years of service for your back-up power requirements.
Refer to the cross-reference table below to understand which unit with its power
capability corresponds to your particular model number.
CHAPTER 1
CHAPTER 1
CROSS REFERENCE TABLE
MODEL NUMBER
ED-1000-1 1000
ED-1500-1 1500
ED-2000-1 2000
OUTPUT POWER (VA)
The FALCON®ED Series represents one of the smallest and most compact
units of the FALCON®UNINTERRUPTIBLE POWER SYSTEM (UPS) product
line. In the tradition of all FALCON®products, it maintains the highest reliability
and the most complete on-line, sinewave power protection available. An online, sinewave UPS is the only total solution to virtually any power problem. It
effectively provides just what it says, UNINTERRUPTIBLE POWER. There is
no break, transient or glitch in source transfer during a power failure because
THERE IS NO TRANSFER.
The FALCON®ED SERIES is engineered with the latest MOSFET/PWM
technology for high efficiency and reliability.
2
Refer to the simplified block diagram, Figure 1, for a system description. The
EMERGENCY
EMERGENCY
AC source is rectified and provides energy for the DC + Choppers and a float
charge to a standby battery. These DC Choppers then supply the power to
operate the DC/AC Inverter.
During a utility power-loss, the AC rectification and battery charging capabilities
of the UPS become inactive. The fully-charged battery, however, supplies the
necessary power requirement to maintain the remaining system blocks.
The FALCON®ED on-line topology is unique to other on-line system because it
is designed to meet the needs of non-linear loads. Your computer, with its
switching power supply, is considered a non-linear load which can be very
abusive to most power protection equipment and could decrease its lifeexpectancy. The FALCON®ED unit is specially devised to accept these loads
and protect them efficiently without any of the output waveform degradation
common to other UPS.
Referring again to the figure below, you will notice a built-in safeguard. If the
unit inadvertently experiences an extreme over-temperature situation that
causes inverter malfunction, it will switch over to a filtered emergency bypass
line to ensure continuous power to the computer load. In the event the UPS is
overloaded for 15 seconds, it will shutdown completely.
INPUT
FILTER
FIGURE 1: FALCON ED SERIES BLOCK DIAGRAM
BYPASS LINE
RECTIFIER
CHARGER
+ DC
CHOPPERS
STANDBY
BATTERY
DC/AC
INVERTER
BYPASS
SWITCH
OUTPUT
FILTER
COMPUTER
(LOAD)
3