E3914i Range
Line L1 L2 L3
Current 38A 38A 38A
Cooking Zone 5kW (x 4)
Oven 6kW
Total Rating 26kW
After installation, the engineer should check satisfactory
operation and demonstrate method of use to kitchen staff.
Location of mains isolating switch should be identified for
use in the event of an emergency or during cleaning.
SECTION 2 - ASSEMBLY and
COMMISSIONING
NOTE: Users MUST be made aware that individuals
fitted with a pacemaker should consult their doctor if
in close proximity to this unit. This induction unit
emanates a 18 - 22Khz output that may effect older
types of pacemaker.
2.1 ASSEMBLY
a) Unpack and level appliance
b) Ensure fan intake filter is fitted and secured in position
below RH front panel.
2.2 CONNECTION TO AN ELECTRICAL SUPPLY
Connect as detailed in Sections 1.3 and 1.4.
2.3 STARTING UP
a) Switch all four cooking zones on to Position 10.
b) Ensure all four LEDs light and begin to flash.
c) Place suitable pan (filled with water) upon a zone.
(Pan bases should be constructed of a ferrous
material and not less than Ø120mm)
d) Ensure zone LED stops flashing and remains lit.
e) Remove pan from zone. LED should begin to flash.
This indicates the “pan detection” feature is working.
f) Repeat on all four cooking zones.
g) Leave pots to heat until water boils and switch controls
to maintain simmer.
i) Switch control OFF.
j) Switch oven ON and ensure both fans are running.
k) Push oven light switch and hold. Ensure both lamps
operate correctly.
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE
BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBER, NETT WEIGHT
and DIMENSIONS
1.2 SITING
The appliance should be installed in a well-lit position on
a firm, level, non-combustable floor. Where unit is to be
positioned in close proximity to a wall, partition, kitchen
furniture, decorative finishes, etc., it is recommended that
these be constructed of a non-combustible material.
If this is not possible they should be clad in a suitable
non-combustible, heat-insulating material. Close
attention should be paid to fire egulations.
1.3 ELECTRICAL SUPPLY
The unit is suitable for AC supplies only. Standard
terminal arrangement is a 3 phase / Neutral 5 wire
connection (400V 3N~)
WARNING – THIS APPLIANCE MUST BE EARTHED
Phase 1 BROWN
Phase 2 BLACK
Phase 3 GREY
Neutral BLUE
Earth YELLOW/GREEN
1.4 SUPPLY CONNECTION
The unit must be installed using a mains input connecting
cable of at least 6mm², type HO7RN-F, conforming to
code designation 60245 IEC 57.
A suitably rated isolating switch with contact separation of
at least 3mm in all poles must be installed and wiring
executed in accordance with relevent regulations.
Access to terminal block is gained by removing an
access panel close to cable entry gland on rear panel.
1.5 ELECTRICAL RATINGS
Electrical loading is as stated on appliance data plate.
E3913i Range
Line L1 L2 L3
Current 29A 29A 29A
Cooking Zone 3.5kW (x 4)
Oven 6kW
Total Rating 20kW
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3913i Range 900 820 890 140
E3914i Range 900 820 890 140
3