Falcon Dominator Plus G3151, Dominator Plus G3151D, Dominator Plus G3150 Installation And Servicing Instructions

Page 1
DOMINATOR
PLUS
G3151 Fusion Range G3150 Fusion Boiling Top
This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to:
Gas Safety (Installation & Use) Regulations Health And Safety At Work etc. Act Local and National Building Regulations Fire Precautions Act
Detailed recommendations are contained in Institute of Gas Engineers published documents: IGE/UP1, IGE/UP/2 BS6173 and BS5440
The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for the Countries, Gas Types and Pressures as stated on the data plate.
WARNING: TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC,
MUST BE EARTHED.
On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference during servicing. Further to this, The Users Instructions should be handed over to the User, having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a licenced waste handler. Units are designed to be dismantled easily and recycling of all material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000 Fax: 01438 369 900
T100850 Ref. 2
Page 2
IMPORTANT INFORMATION Warranty Policy Shortlist
Warranty does not cover :-
• Correcting faults caused by incorrect installation of a product.
• Where an engineer cannot gain access to a site or a product.
• Repeat commission visits.
• Replacement of any parts where damage has been caused by misuse.
• Engineer waiting time will be chargeable.
• Routine maintenance and cleaning.
• Gas conversions i.e. Natural to Propane gas.
• Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted, or are fitted and not maintained.
• Blocked drains
• Independent steam generation systems.
• Gas, water and electrical supply external to unit.
• Light bulbs
• Re-installing vacuum in kettle jackets.
• Replacement of grill burner ceramics when damage has been clearly caused by misuse.
• Where an engineer finds no fault with a product that has been reported faulty.
• Re-setting or adjustment of thermostats when unit is operating to specification.
• Cleaning and unblocking of fryer filter systems due to customer misuse.
• Lubrication and adjustment of door catches.
• Cleaning and Maintenance
• Cleaning of burner jets
• Poor combustion caused by lack of cleaning
• Lubrication of moving parts
• Lubrication of gas cocks
• Cleaning/adjustment of pilots
• Correction of gas pressure to appliance.
• Renewing of electric cable ends.
• Replacement of fuses
• Corrosion caused by use of chemical cleaners.
Page 3
Model kW Btu/hr Open Top 5.3 20,000 Fusion Burner (Nat Gas) 7.5 28.100 Fusion Burner (Propane) 5.5 20,600 900mm Oven 7.1 26,700
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBERS, NETT WEIGHTS
and DIMENSIONS
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
G3151 Fusion Range
900 770 890 129
G3151D Fusion Range
600 770 890 129
G3150 Fusion Boiling Top
900 770 455 70
1.2 SITING
The appliance should be installed on a level, fireproof surface, in a well lit and draught free position.
If the floor is constructed of combustible material, then local fire requirements should be checked to ensure compliance. A clear space of 150mm should be left between rear and side of unit and any combustible wall.
Important
If a unit is to be installed in suite formation with other matching appliances, the instructions for all models must be consulted to determine the necessary clearances to any combustible rear wall or overlying surface. Some models require greater clearances than others and the largest figure quoted in individual instructions will therefore determine the clearance for the complete suite of adjoining appliances.
The oven flue discharges vertically through hob rear. There must be no direct connection of flue to any mechanical extraction system or to the outside air. Open top burners discharge combustion products directly into the room.
Care should be taken not to disturb the air combustion admission nor the combustion products evacuation of appliances fitted with open burners.
1.3 VENTILATION
Adequate ventilation must be provided to supply sufficient fresh air for combustion and allow easy removal of combustion products which may be harmful to health. Recommendations for Ventilation of Catering Appliances are given in BS5440:2.
For multiple installations the requirements for individual appliances should be added together. Installation should be made in accordance with local and/or national regulations applying at the time. A competent installer MUST be employed.
1.4 GAS SUPPLY
The incoming service must be of sufficient size to supply full rate without excessive pressure drop.
A gas meter is connected to the service pipe by gas supplier. Any existing meter should be checked by supplier to ensure it is of adequate capacity to pass required rate for appliance in addition to any other gas equipment installed.
Installation pipe work should be fitted in accordance with IGE/UP/2. The pipe work should be of adequate size but not smaller than unit gas inlet connection, ie. Rp¾ (¾” B.S.P.). An isolating cock must be located close by to allow shut-down during an emergency or servicing.
If flexible tube is used, the gas supply tubing or hose shall comply with national requirements in force. These will be periodically examined and replaced as necessary.
The installation must be tested for gas tightness. Procedure details can be found in IGE/UP/1.
The adjustable governor supplied must be fitted to natural gas appliances.
1.5 ELECTRICAL SUPPLY
Not applicable to this appliance.
1.6 WATER SUPPLY
Not applicable to this appliance.
1.7 HEAT INPUTS - NATURAL and PROPANE
GAS (kW net & Btu/hr gross)
1.7.1 Total Inputs
Model kW Btu/hr G3151/D (Nat Gas) 41.4 154,250 G3151/D (Propane) 39.1 146,750 G3150 (Nat Gas) 34 127,600 G3150 ( Propane) 32 120,100
1.7.2 Individual Inputs (kW nett & Btu/hr gross)
Page 4
1.8 INJECTOR DIAMETERS
Model Natural Propane Open top Ø1.93mm Ø1.2mm Fusion Burner Ø1.0 mm Ø 0.5mm Ovens Ø2.2mm Ø 1.33mm
1.8.1 Fusion Burner pilot Injectors
Natural Gas Propane Gas G27.2 G22.1
1.9 GAS PRESSURE ADJUSTMENT NATURAL and PROPANE GAS
The following supply pressures apply to both all units.
Gas type mbar Natural 20 Propane 37
Pressure test point is located on RH side of gas manifold situated behind the front control panel.
An adjustable governor (¾ BSP) is provided on Natural gas units.. This should be adjusted to achieve an operating pressure at control manifold of 15mbar. For muti-burner systems, approximately half of the
burners should be on when setting governor pressure.
1.10 BURNER ADJUSTMENTS NATURAL and
PROPANE GAS.
1.10.1 Burner Aeration
Open top, fusion and oven burners are fitted with fixed injectors and set aeration apertures.. NO ADJUSTMENT is possible.
1.10.2 Bypass Screw Diameters
Minimum gas flow to burner is governed by size of fixed by-pass screw hole as follows:-
Natural Gas Propane Gas
Model
Marked Marked Open Top 76 51 Oven 93 55
The fusion burner has no bypass screw.
Page 5
SECTION 2 - ASSEMBLY and
COMMISSIONING
Fixings
2.1 ASSEMBLY Note
The following paragraphs should be read as applicable to the unit being assembled.
a) Unpack appliance and place it in position using feet
adjusters to level appliance.
b) Units with castors should be fitted with accessories
supplied according to separate instructions provided.
c) Open oven door, pull out shelves and base panel.
Check burner spark igniter arrangements are correctly located and secured. Ensure ALL packing, etc. is removed from oven. Replace all parts in reverse sequence.
d) Check open top and remove tape, packing, etc. from
hob area and ensure that all burners and pan supports are secured in position. The open top burner heads fit loosely upon aluminium bases of lift-off construction.
2.1.1 Fryplate Accessory
If fryplate (Figure 2) is supplied, refer to user instructions for details. Important note: this should be operated on a low flame setting only.
2.1.2 Flue Accessory
A tall flue is available as an accessory that may be substituted for standard type supplied with unit. Details of the alteration process are indicated in Figures 3 through 6. Remove hob as detailed in Sections 3.2.2 and 3.2.3. Undo and remove fixings at locations shown in Figure 3. Remove fixings at rear detailed in Figure 4. Install replacement flue as detailed in Figure 5 and secure using existing fixings at hob and rear at positions indicated in Figures 5 and 6.
Important Note: It is not possible to fit a splashplate / plateshelf to a unit fitted with a tall flue.
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Fixings
Fixings
Fixings
Page 6
2.2 CONNECTION TO GAS SUPPLY
Connect appliance to gas supply and ensure that the governor supplied is fitted on NATURAL gas installations. Test for gas tightness.
The integral gas supply downstream of gas valve may be checked by applying leak detection spray with burner lit. Appliance inlet connection terminates at upper rear RH side in Rp¾ (¾" BSP female).
2.3 CONNECTION TO ELECTRICAL SUPPLY
Not applicable to these appliances.
2.4 CONNECTION TO WATER SUPPLY
Not applicable to these appliances.
2.5 COMMISSIONING THE APPLIANCE Important
Prior to operation, ensure that ALL packing material has been removed.
2.5.1 Setting the Gas Pressure
a) It is necessary to check gas pressure during
commissioning and a suitable gauge must be connected to test point on RH side of supply manifold
(situated behind front control facia). b) Turn on main gas valve at supply to unit. c) Light three open top burners as detailed in Section
2.5.3. Gas supply pipes may contain air so repeat
procedure until burner lights. d) Adjust governor (Natural gas installations only) at unit
rear to relevant pressure setting found in Section 1.9.
To increase pressure - turn screw clockwise
(or anti-clockwise to decrease). Check again after
15 minutes of operation. e) Disconnect gauge. Replace test point sealing screw
and test for gas tightness.
2.5.2 Checking Performance of the Controls
a) Light open top or oven as detailed in Section 2.5.3.
Check ignition is smooth and without delay.
Repeat operation several times. b) Place a thermocouple at oven centre and select 210°C
setting. Allow oven to heat up and check temperature
is 210°C (+/-10°C). If reading is outwith specified
range, the thermostat may be faulty. In this case, unit
should be serviced (see thermostat replacement and
calibration procedure). Turn gas supply to oven OFF
and allow a sufficient cool-down period before
removing thermostat.
2.5.3 Lighting Sequence Important
Prior to operation, ensure ALL packing material has been removed from appliance.
Open Top
1.
Ensure mains gas is turned on.
2.
To light hob burners, press knob and turn to full flame
position. Ignite burners using taper or match. Hold in knob for 20 seconds and then release. Burner will remain lit. Turn knob to required position.
Oven
1.
Ensure mains gas is turned on.
2.
Open oven doors.
3.
Turn thermostat knob to maximum setting and push in.
This will establish a flow of gas to oven burner.
4.
Continue to press knob in and at the same time, push piezo spark ignitor button situated on control panel to provide a spark at oven burner. Press at 1 sec intervals for 8 times only.
5.
Having established burner flame, maintain pressure on
knob for a further 20 seconds before release.
6.
Burner should remain lit. Should burner fail to remain lit, wait 3 minutes then return to Step 2 and repeat ignition procedure.
7.
When burner remains lit, turn thermostat to required temperature setting.
To Shut Oven OFF
To extinguish oven flame, turn thermostat to OFF position.
2.6 INSTRUCTION TO USER
The installer must ensure that user thoroughly understands the instructions for lighting, cleaning and correct use of unit. It is also important to ensure that gas isolating cock location is known to user and that the procedure to follow in event of emergency is demonstrated.
Page 7
SECTION 3 ­SERVICING AND CONVERSION
Important
BEFORE ATTEMPTING ANY SERVICING, ENSURE ISOLATING COCK IS TURNED OFF AND CANNOT BE INADVERTENTLY TURNED ON. AFTER ANY MAINTENANCE TASK, CHECK APPLIANCE TO ENSURE THAT IT PERFORMS CORRECTLY AND CARRY OUT ANY NECESSARY ADJUSTMENTS AS DETAILED IN SECTION 1.
After carrying out any servicing or exchange of gas carrying component.
ALWAYS CHECK FOR GAS TIGHTNESS!
3.1 GAS CONVERSION CHECK LIST
For All Appliances
CHANGE INJECTORS CHANGE BY-PASS SCREW AND SET LOW RATE . Refer to Section 1.10. CHANGE DATA PLATE
Ensure gas supply is disconnected before commencing. Only reconnect gas supply after all conversion work has
been completed.
Natural to Propane
Remove governor from appliance inlet pipe-work.
Propane to Natural
Fit governor to appliance inlet pipe-work and follow details in Section 2.5.
3.1.2 Open Top Low setting Screw - To Replace (Figure 7)
a) Remove control panel. b) Unscrew and remove existing low position screw from open top tap. c) Insert replacement screw into open top tap and
secure. Repeat for all taps.
d) Refit control panel.
3.1.3 Oven Burner - To Replace Injector
a) Remove oven shelves and base plate. b) Disconnect Gas supply pipe. c) Unscrew and remove existing injector. d) Insert and screw in replacement injector.
e) Re-connect Gas supply pipe.
3.1.4 Thermostat - To Replace Bypass Screw (Figure 7)
a) Remove control panel. b) Unscrew and remove existing bypass screw from
thermostat.
c) Insert replacement bypass screw and secure into
thermostat.
d) Re-assemble in reverse order.
3.1.1 Open Top Burners - To Replace Injector
(Figure 8)
a) Remove pan supports. b) Remove burner heads and burner bezels. c) Remove pressed hob by pulling upwards.(Do not
remove screws in hob.)
d) Leaving injector holders in situation, unscrew existing
injectors. e) Remove injectors. f ) Insert replacement injectors and secure. Repeat for all
taps g) Refit removed parts.
Open top low setting screw
Thermostat bypass screw
Figure 7
Open top injector
Figure 8
Page 8
3.1.5 Solid Top Burner - To Replace Injector
(Figure 9)
a) Remove solid top castings. b) Release pilot assembly from burner. c) Remove burner. d) Unscrew and remove existing injector. e) Insert and screw in replacement injector. f) Refit burner and ensure burner aeration adjustment. (see Section 1.10)
Pilot injector
a
) Remove pilot pipe from pilot assembly. b) Remove existing pilot injector from pilot pipe. c) Fit replacement injector over pipe
d) Refit pilot pipe to pilot assembly.
e) Refit pilot assembly to burner. f) Leave solid top castings off to allow manometer to be
fitted to burner test point.
3.1.6 Resetting Low Rate Screw (Figure 10)
a) Remove control panel. b) Fit manometer to burner test point. c) Connect replacement gas supply to appliance. d) Light solid top burner. e) While burner is ignited turn solid top tap to the low
flame position.
f ) Turn screw until manometer reading is stated in the
table indicated in Section 1.10.2. g) Refit control panel. h) Remove manometer from burner test point, ensuring
no gas leaks. Reassemble solid top castings.
Ensure data plate with correct information is fitted after conversion.
3.2 REMOVAL OF CONTROL PANELS
Various panels are removed as follows:
3.2.1 To Remove Facia Panel
Remove control knob(s). Open oven doors and undo fixings along underside and top. Pull facia panel forward while slightly easing bottom edge upward to remove.
3.2.2 To Remove Open Top Hob Components
Remove pan supports and burner heads complete with aluminium bezels and venturi that sit loosely upon injector holder. The hob is retained by ballstud fixings at each corner. Lift hob clear to access burner support brackets.
3.2.3 To Remove Hob
Remove fixings that secure front hob support and fixings that secure flue to back panel. Lift full hob area ­including flue - clear of unit.
3.3 REMOVAL OF DROP-DOWN DOOR
Open door completely and insert a suitable pin into marked hole on both hinges.
Hinge hole
The action of closing door will result in the hinge pulling out of bracket to allow door to be removed.
Due to hinge springs being under tension, do not disturb pins while door is removed from range.
Replace in reverse order.
3.4 BURNERS
3.4.1 Open Top
Remove hob components as Section 3.2.2. Undo burner pipe compression fitting. Undo injector holder fixings. Withdraw burner body. Replace in reverse order.
3.4.2 Oven
Open oven doors and remove base panel. Undo Gas connection. Remove tie wrap, pull back insulated sleeving and disconnect igniter lead at spark electrode end. Undo FFD thermocouple at burner. Undo fixings that secure burner feet to base panel. Remove oven burner. Replace in reverse order, ensuring correct dimensions for Spark electrode and FFD Thermocouple. (fig 12)
3.5 CLEANING
3.5.1 Burners
Burners should be cleaned daily to maintain maximum performance. Open top burners should be cleaned as detailed in User Instructions. Additional burners are best cleaned with a wire brush; port blockage should be freed using a metal broach, any loose material being shaken out via burner shank.
Ensure burners are dry and free from any cleaning material before replacing.
Check adjustment as detailed in Section 1.
Figure 9
Solid top pilot pipe
Page 9
Solid top low flame adjustment screw
Solid top burner test point
3.5.2 Injectors
Injectors are best cleaned with a wooden splinter or soft fuse wire. Metal reamers may distort or increase orifice size and their use should be avoided.
3.6 THERMOCOUPLES and
FLAME FAILURE DEVICE (FFD)
3.6.1 Open Top Flame Failure Device Magnet Unit
To remove and replace FFD magnet unit, the following procedures must be followed. Isolate Gas supply. Remove hob components as detailed in Section 3.2.2. Undo FFD thermocouple at rear of tap, undo FFD section at tap rear and withdraw. Replace in reverse order.
3.6.2 Open Top Thermocouple
Remove hob as detailed in Section 3.2.2. Remove nut that secures thermocouple to burner support bracket and pull thermocouple through support bracket from underside. Undo thermocouple connection at FFD section of gas tap and carefully remove thermocouple. Replace in reverse order, taking care to position tip correctly in relation to burner ports. Thermocouple tip should be 35mm above support bracket. Ensure thermocouple does not touch any part of burner when fully re-assembled. (Fig 11)
3.6.3 Oven Flame Failure Device Magnet Unit
The oven FFD magnet unit is an integral thermostat part. Remove hob components as detailed in Section 3.2.2 to gain access to FFD. Isolate Gas supply. Undo FFD thermocouple at thermostat rear. Undo rear FFD section and withdraw. Replace in reverse order.
Figure 12
3.6.4 Oven Thermocouple To Remove Thermocouple
Remove facia panel as detailed in Section 3.2.1. Remove hob fitments. See Sections 3.2.2 or 3.2.3 as required. Remove RH side panel. Undo thermocouple nut at thermostat rear. Open over doors. remove shelves and base plate. Undo nut that secures thermocouple to burner bracket. Remove sensor from burner bracket. Release thermocouple from clips in oven chamber. Remove Thermocouple by feeding through slot in oven side panel. Replace in reverse order, taking care not to over tighten, ensure side wall insulation around thermocouple access slot is undamaged then ensuring position as indicated in Figure 12.
3.7 OVEN IGNITERS and ELECTRODES
Igniter is piezo spark type and contains no batteries. Unit comprises piezo spark igniter, lead and electrode assembly. Lead and earth lead are push-fit at igniter end. Oven igniter electrode, Thermocouple, and burner ports should be aligned as indicated in Figure 12.
3.7.1 Oven Igniter
Remove facia panel as detailed in Section 3.2.1. Disconnect igniter earth wire and . Pull back insulated sleeve and remove igniter lead connection from spark igniter.
Undo nut that secures igniter in position. Remove Igniter. Replace in reverse order,
3.7.2 Oven Electrode
Remove oven shelves and base plate. Remove tie wraps and pull back insulated sleeve.
Disconnect igniter lead from electrode. Undo fixing that secures electrode to burner bracket. Remove electrode and replace in reverse order ensuring position is as indicated in Figure 12.
Note: Care should be taken not to damage electrode Important: if spark is present but burner will not light, ensure gas is present and dimensions are as (Fig 12)
Figure 11
Page 10
3.8 OVEN THERMOSTAT
Remove control knobs and fascia panel as detailed in Section 3.2.1. Remove hob fitments as detailed in Sections 3.2.2 and
3.2.3 as appropriate. Undo thermocouple connection at thermostat rear. Disconnect oven burner pipe. From inside oven, release clips that secures thermostat capillary to oven side wall. Undo fixings that secure thermostat to manifold. Remove thermostat by carefully feeding capillary and phial through crown plate. Replace all parts in reverse order. Renew manifold gasket if necessary.
3.8.1 Thermostat Calibration
The thermostat should not be calibrated. If temperature is outwith specified tolerances, replace thermostat and return faulty thermostat to Falcon Quality Department.
3.9 OPEN TOP and SOLID TOP GAS TAPS Note Plugs and bodies are machined in pairs and are therefore not interchangeable. Always clean one tap at a time.
3.9.1 Service - Isolate from gas supply.
Remove control knobs and fascia panel as detailed in Section 3.2.1.
Remove fixings from front of tap body. Withdraw spindle and niting arrangement to allow plug to be eased out. Clean gas tap plug with a soft rag and regrease using an approved high temperature lubricant. Take care not to over-grease as surplus may cause gasway blockage. Replace parts in correct order and check gas tightness.
3.9.2 Removal – isolate from gas supply.
Remove control knobs and fascia panel as detailed in Section 3.2.1.
Remove hob fitments as detailed in Sections 3.2.2 and
3.2.3 as appropriate. Disconnect thermocouple connection at gas tap rear.
3.10 GOVERNOR (Natural Gas Models Only)
The governor supplied is maintenance free. Check that blue dust cap is covering vent and in good condition as this protects the breather hole.
When checking for gas leaks around governor, be aware that unburned gas may be vented occasionally to release pressure on diaphragm. This should not be confused with a gas leak.
3.11 FAULT CHECK LIST If a flame is not established on any burners (hob or oven), follow this check list.
1.
Check mains gas is ON.
2.
Check pressure at test point to ensure gas is flowing to
unit.
3.
If pressure does not register then check governor is fully operational or check for line blockage.
4.
If gas is present, check burner injector for blockage.
5.
If injector is OK then check FFD is engaging and passing gas.
6.
OVEN ONLY - Check for spark at spark electrode.
7.
OVEN ONLY - If there is no spark then check spark d i m e n s i o n s ( f i g 1 2 ) and HT lead connections. Also check igniter.
8.
OVEN ONLY – Note: Spark may be present but will still not light burner unless dimensions relative to burner are as Fig 12.
Note: If after adjusting the electrode to the correct dimensions (fig 12), a spark is not present, or is present but will not light burner, check the following:
Check Spark lead and return earth wire connections at piezo spark igniter body.
Check for clean contact between burner fixing feet and oven base, using spring washers under screw heads.
9.
If flame is still not present, then re-check from start.
If flame is established but not maintained, follow this check list.
1.
Check thermocouple is positioned correctly in burner flame. (fig 12) Burner ports must be clean.
2.
Check thermocouple is not damaged and is secured to gas valve FFD section to allow FFD to energise.
3.
Check FFD is energising and maintaining flame.
4.
If, after carrying out the above, burner is still not maintaining flame then re-check from start.
SECTION 4 - SPARES and
ACCESSORIES
When ordering spare parts, always quote appliance type and serial number.
This information will be found on data badge attached to base plate.
Loading...