Falcon Dominator Plus E3441, Dominator Plus E3481, Dominator Plus E3441R, Dominator Plus E3481R Installation And Servicing Instructions

DOMINATOR
PLUS
E3441, E3441R, E3481, E3481R GRIDDLE PLATES
INSTALLATION and SERVICING INSTRUCTIONS
CAUTION - READ THESE INSTRUCTIONS BEFORE INSTALLING, COMMISSIONING OR USING THIS APPLIANCE!
The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to:
BS7671 IEE Wiring Regulations Electricity at Work Regulations Health And Safety At Work Act Fire Precautions Act
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.
WARNING: THIS APPLIANCE MUST BE EARTHED.
On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference during servicing. Further to this, The Users Instructions should be handed over to the User, having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
Upon receipt of the instruction manual, the installer must notify the responsible person(s) with regard to correct operation and maintenance of the unit. This equipment is ONLY INTENDED FOR PROFESSIONAL USE and to be operated by QUALIFIED PERSONS.
It is the responsibility of the Supervisor or equivalent to enure that any user wears SUITABLE PROTECTIVE CLOTHING. Attention should also be drawn to the fact that some parts of the unit will, by necessity, become VERY HOT to the extent that burning could occur if these are touched accidentally.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a licenced waste handler. Units are designed to be dismantled easily and recycling of all material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000 Fax: 01438 369 900
T100825 Ref. 3
IMPORTANT INFORMATION Warranty Policy Shortlist
Warranty does not cover :-
• Correcting faults caused by incorrect installation of a product.
• Where an engineer cannot gain access to a site or a product.
• Repeat commission visits.
• Replacement of any parts where damage has been caused by misuse.
• Engineer waiting time will be chargeable.
• Routine maintenance and cleaning.
• Gas conversions i.e. Natural to Propane gas.
• Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted, or are fitted and not maintained.
• Blocked drains
• Independent steam generation systems.
• Gas, water and electrical supply external to unit.
• Light bulbs
• Re-installing vacuum in kettle jackets.
• Replacement of grill burner ceramics when damage has been clearly caused by misuse.
• Where an engineer finds no fault with a product that has been reported faulty.
• Re-setting or adjustment of thermostats when unit is operating to specification.
• Cleaning and unblocking of fryer filter systems due to customer misuse.
• Lubrication and adjustment of door catches.
• Cleaning and Maintenance
• Cleaning of burner jets
• Poor combustion caused by lack of cleaning
• Lubrication of moving parts
• Lubrication of gas cocks
• Cleaning/adjustment of pilots
• Correction of gas pressure to appliance.
• Renewing of electric cable ends.
• Replacement of fuses
• Corrosion caused by use of chemical cleaners.
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBERS, NETT WEIGHTS
and DIMENSIONS
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3441 400 770 455 59
E3441R 400 770 455 59
E3481 800 770 455 98
E3481R 800 770 455 98
1.2 SITING
The appliance should be installed on a level, fireproof surface, in a well lit and draught free position.
If floor is constructed of combustible material, local fire requirements should be checked to ensure compliance. A clear space of 150mm should be left between rear and side of unit and any non-combustible wall.
If this is not possible these surfaces should be clad in a suitable non-combustible, heat-insulating material. Close attention be paid to fire regulations.
1.3 ELECTRICAL SUPPLY
The units are suitable for AC supplies only. The E3441/E3441R models are for use on single phase supplies only. E3481/E3481R models can be operated on single phase or alternatively on a 2 phase supply.
WARNING - THIS APPLIANCE MUST BE EARTHED
1.4 SUPPLY CONNECTION
A suitable mains input cable should be fitted that conforms to code designation 60245 IEC 57, cable type H07RN-F.
A suitably rated isolating switch with contact separation of at least 3mm in all poles must be installed and wiring executed in accordance with relevant regulations.
Access to mains terminal block is gained by removing control panel.
E3481/E3481R
Links should be inserted as detailed in Figure 1 to convert from two phase to single phase supply. Consideration must be given to required draw of current.
Figure 1
1.5 ELECTRICAL RATINGS
Electrical loading is as stated in table below and also on appliance data plate.
The location of mains isolating switch should be identified for use in any event of an emergency or during cleaning.
1.5.1 E3441/E3441R
Connection Amps (A)
L1 14.97
1.5.2 E3481/E3481R
Connection Amps (A)
L1 14.97 L2 14.97
SECTION 2 - ASSEMBLY and
COMMISSIONING
Note
The following information should be read as applicable to the unit being assembled.
2.1 ASSEMBLY
a) Position unit. Level it using feet adjusters. To mount
unit upon a purpose built stand, refer to details supplied with stand.
b) Unit is supplied with terminals for connection to a
suitable mains supply. All wiring must be in accordance with local regulations.
c) To gain access to terminals, remove control panel and
proceed as follows: d) Remove fat drawer. Undo and remove upper fixings. e) Undo fixings below control panel. Remove panel
carefully and set aside. f) Terminals are now accessible and supply cables can
be fed through rear of unit. g) After connecting mains supply, replace control panel
and fat drawer.
2.2 CONNECTION TO AN ELECTRICAL SUPPLY
Connect as detailed in Sections 1.3 and 1.4.
2.3 STARTING UP
Switch on mains supply, red neon will light. Click on/off switch to ON. Amber neon will light.
2.4 INSTRUCTION TO USER
After installation and commissioning is completed, please hand User Instructions to user.
Ensure that person(s) responsible understand correct operation and cleaning of appliance.
SECTION 3 - SERVICING and
MAINTENANCE
BEFORE ATTEMPTING ANY MAINTENANCE, ISOLATE APPLIANCE AT MAIN SWITCH AND TAKE STEPS TO ENSURE THAT IT IS NOT INADVERTENTLY SWITCHED ON.
Warning
Since the plate is very heavy, care must be exercised when lifting it up to carry out maintenance. The initial lifting points are through side holes of splash guard. A suitable batten of wood should be inserted between plate and front hob rail to support the weight.
Rest plate upon a batten and take a strong grip below plate front edge. Raise to the desired angle for access.
Place a wooden prop to support the weight below plate. Ensure prop is secured to prevent accidental slipping.
Ensure unit base, which is considerably lighter than plate, cannot move during lifting.
When ordering spares, please quote model number, serial number and voltage as stated on data plate.
3.1 CONTROL PANEL - To Remove
a) To gain access to terminals, remove control panel and
proceed as follows: b) Remove fat drawer. Undo and remove upper fixings. c) Undo fixings below control panel. Remove panel
carefully and set aside.
3.2 THERMOSTAT - To Replace
Remove control panel as detailed in Section 3.1. Undo element tail connections before lifting plate.
Remove fixings that secure plate in position within control compartment top. Raise plate from front.
Prop it up with a suitable piece of wood. Take care not to strain thermostat capillary tube.
Undo clamping plate fixings to release phial. Pull off thermostat connections, noting the locations
according to wire numbers. Pull off thermostat knob and remove fixings below to release control from panel.
Feed capillary tube and phial forward through rear of control compartment and remove assembly.
Replace in reverse order, taking care to fit insulating sleeving over capillary before fitting thermostat. (Refer to
Figure 2)
Ensure earth bonding connection is replaced behind thermostat fixing lug. After fitting thermostat, test unit using a low setting. Check amber light goes out when set temperature is reached.
Loading...