C M I Series IIX Software Release - Revision 19
Several new features have been added to release version 19.
* Page I General Interface MIDI configuration setup can be saved as a preset
file on disk.
* Page 2 and L display the new Page I MIDI configuration file.
* Page 7 Control Parameters allows patching KEY NUMber to FILTER~. Filter
response can be further modified by a function curve.
* Page S Screen Print has selectable Baud rate, and keyboard commands to toggle
Auto Form Feed and Inversion.

C M I Series IIX Software Release - Revision 19 (continued)
PAGE I
Page I MIDI setup can be saved to disk as a .MC file allowing instant recall of
complex MIDI patches. Some SMPTE parameters are saved also. These are:
time code reader frame rate
time code generator frame rate
drop frame switch rate
jam sync switch rate.
To save a MIDI setup, type
SAVE FILENAME.MC<return>
When the file has been saved, its name will appcar in the CFG: box at the bottom
lefthand of screen. Note that you must type the .MC part of the filename.
Otherwise, it will be assumed that filenameis a voice and will probably display
the error message FILENAME NOT LOADED.
To load a previously saved MIDI file, type
LOAD FILENAME.MC<return>
The filename will appear in the CFG: box as previously described. Whenever you
load a .MC file, it will turn off the time code reader and generator.
To reset Page I, save the default (normal) setting as a file. Thcn, later on,
loud that same file when you want to reset Page 1.
Page I MIDI configuration files (ending in.MC) can only be loaded or saved from
Page I.
Page 2 and Page L can display files with the .MC suffix.