Fairford HFE-30 Basic Manual

Page 1
Hfe
Digital Soft Starters
FAIRFORD
ELECTRONICS
HFE-30 30 Amp @ 110-230 Volts
APPLICA TION
HFE Energy Saving soft starters are designed to control single phase AC motors. Operation is fully automatic, a low starting voltage is applied to the motor as soon as the supply is switched on. The internal automatic ramp control immediately takes over and raises the voltage progressively, causing the motor to accelerate smoothly.
At the end of the ramp period, the motor is operated in Energy Saving mode and the HFE continuously regulates the voltage to match mechanical load.
Energy consumption at light loads is reduced, motor winding and case temperatures are lowered, motor life is extended, noise levels are reduced and power factor is improved.
The LED in the unit indicates when the unit is ENERGY SAVING. As energy consumption is reduced the ENERGY SAVING LED flashes at a slower rate.
The HFE remains in circuit until the supply is discon­nected. The HFE automatically resets and is ready for the next start.
Soft Starters and Energy
Optimising Soft Starters
Safety at Work
ISOLATE FROM THE SUPPLY BEFORE WORKING ON THE UNIT OR MOTOR
It is the responsibility of the installer and user to ensure that this equipment is installed, operated and maintained in accordance with the Health and Safety at Work Act in the United Kingdom and all applicable legislation, regulations and codes of practice relevant to your location.
Only qualified personnel should install this equipment, after first reading and understanding this document. The installation instructions must be followed, and any questions or doubt must be referred to the supplier of the equipment.
The system may be configured to allow for auto restart controlled from contacts on the motor side of the unit. Users and operators must always take all necessary precautions to prevent damage to equipment and especially to prevent the risk of injury to personnel working on or near the motor and driven equipment.
The manufacturer does not assume any liability, express or implied, for any consequences resulting from inappropriate, negligent or incorrect installation, application, use or adjust­ment of the product or circuit design, or from mismatching of a soft starter to a motor.
page 1 M-2025-F 081007
Page 2
Mechanical Details HFE-30
195
215
MOUNTING
The module must be fixed to a vertical surface. To ensure free air movement a minimum clearance of 40mm must be maintained above and below the unit.
228
25
Three off Ø21mm holes for cable glands
40.2 40.2
97.5
59.2
L, N,
M M N, L
mm
1
2
AWG mm Nm lbs-inch mm
1.5-25 12 - 4 13 2 18 0.8 x 4
MM
LN
NL
- Supply Live
- Supply Neutral
- Motor Neutral
- Motor Live
Earth/Ground M5 Screw
LED
indicator
ML MN N L
Ramp time
Optimise link, J1
“fridge mode link, J4”
page 2 M-2025-F 081007
Page 3
WIRING
The soft starter is normally inserted into the circuit between the motor and whatever switchgear is normally used for isolation or switching. The unit can also be fitted before switchgear so that it can be installed in the supply to equipment which has it’s own mechanical control.
This feature allows for easy installation on equipment such as refrigeration where the need to disturb internal wiring is avoided.
Supply Neutral
Earth/Ground
Earth/Ground
Supply Live
Motor Neutral
Motor Live
T ypical connection for the HFE.
Extra starting torque may be needed for loads which have a particularly ‘sticky’ starting characteristic. This can be achieved by rearranging the internal connection of the starting capacitor, bringing the connection out and to the supply side of the starter as shown.
Earth/Ground Neutral Live
110/230V~
Motor connected for Capacitor Start - Run
NL MM
Auxiliary
winding
NL
Main
winding
Connect Start Capacitor to Supply live for High Torque or Heavy starting
Centrifugal or voltage switch controls
Star t
start Capacitor
Cap
Run Cap
The terminations are made with industry standard cage clamp screw terminals directly onto the circuit board on all units.
The incoming power supply is connected to the terminals marked ‘L’ and ‘N’. For EMC compli­ance it is important that the line circuit is connected to L and the neutral circuit to N. Outgoing connections from the HFE are taken from the terminals marked ‘LM’ and ‘NM’ to the motor or load input terminals (see diagram). Ensure that a good connection is made to the earth termi­nals provided.
Fuses or other type of short-circuit protection are required for protection against a cable or motor terminal box fault. These must be fitted externally and on the supply side of the unit. See “Specifications” section for recommended fuse type and cut-out device.
Operation
Set the ramp time potentiometer to midway to approx 2 seconds and start the system. If the motor turns instantly when the soft starter is energised and accelerates satisfactorily then no further adjustment is required. If the rate of acceleration is too great stop the unit and turn the ramp time potentiometer clockwise then restart. Adjust anti–clockwise for a shorter ramp time setting to increase the rate of acceleration. The motor should turn instantly when the soft starter is energised. If not, rearrange the connection of the starting capacitor as shown in fig 1
page 3 M-2025-F 081007
Page 4
STARTING
Rating T able
Model Utilisation
Category
AC53a
Allowed start current (X Ie)
HFE-30
The rated
operational
Amps (Ie)
30
Continuous connection
DutyStartLoad
Current
(Amps)
Time
(Secs)
90 3 99% 60
Allowed start
time (S)
time on load (%)
Up to
Starts/Hr
Equally spaced
starts/Hr
current
30A : AC–53a : 3–3:99–60
SPECIFICATIONS
Pedestal Voltage Fixed at ~15%. Start Time: Continuously variable from ½S -5S. Terminations: Cage clamp terminals suitable for 1.5mm2 (12awg)
to 25mm2 (4awg) Ambient Temperature: 0°C to 40°C without derating. Enclosure: IP30 with standard cover: Rated Operational Voltage: Ue: 110 to 230V ac (–15% +10%), 50/60Hz Recommended cut–out device: 32A rated MCB, Trip Characteristic “C“, Form 1. Rated insulation voltage: Ui: 300V. Rated impulse withstand voltage: Uimp: 4kV (1.2/50µs). Short circuit co–ordination: Type 1 , Iq: 5kA when protected by recommended Fuse Fuse Type: Bussmann 170M3113 or Ferraz 6,6 URD 30 D08A 0125. Design standards: IEC 60947–4–2: “AC Semiconductor Motor Controllers and Starters”.
Fairford Electronics Limited, Coombe Works, Derby Road, Kingsbridge, Devon TQ7 1JL, UK
TEL: + 44 (0) 1548 857494 FAX: + 44 (0) 1548 853118
EMAIL: sales@fairford.co.uk WEB: www.fairford.co.uk
Document No. FD202504-F page 4 M-2025-F 081007 ©