Fairchild Semiconductor LM79L05A Datasheet

www.fairchildsemi.com
MC79LXXA/LM79LXXA
3-Terminal 0.1A Negative V oltage R egulator
Features
• Output Current up to 100mA
• No External Components
• Internal Thermal Over Load Protection
• Internal Short Circuit Current Limiting
• Output Voltage of -5V, -8V, -12V, -15V, -18V, -24V
Internal Block Diagram
Description
These regulators employ internal current limiting and thermal shutdown, making them essentially indestructible.
TO-92
1
1.GND 2.Input 3.Output
8-SOP
1
1. Output 2.3.6.7. Input 5. GND 4.8. NC
SOT-89
1
D3
D2
R23+R21
Q16
R28
R24 R25
©2002 Fairchild Semiconductor Corporation
R22
Q15
Q13Q14
R18
Q10
Q11
Q5
R29
Q17
R7
Q6
Q9
C1
R16
Q12
R26
R17
Q8
Q7
Q1
Q4
R27
R1 R2
R6
R3
D1
R4
R15
Q2
R
Q3
GND
Output
R5
Input
Rev. 1.0.2
MC79LXXA/LM79LXXA
Absolute Maximum Ratings
Parameter Symbol Value Unit
Input Voltage (for V (for V (for V
= -12V to -18V)
O
= -24V)
O
= -5V to -8V)
o
Operating Temperature Range T Storage Temperature Range T
V
I
OPR STG
-30
-35
V
-40
0 ~ +125 °C
-65 ~ +150 °C
Electrical Characteristics(MC79L05A/LM79L05A)
(VI = -10V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤T
Parameter Symbol Conditions Min. Typ. Max. Unit
Output Voltage V
Line Regulation (Note1) ∆V
TJ = +25°C -4.8 -5.0 -5.2 V
O
TJ =+25°C
O
+125°C, unless otherwise specified)
J
-7.0V V
-20V - 15 150 mV
I
-8V VI ≥ -20V - - 100 mV
Load Regulation (Note1) ∆V
Output Voltage V
Quiescent Current I
Quiescent Current Change
With Line ∆I With Load ∆I
Output Noise Voltage V Ripple Rejection RR Dropout Voltage V
Note:
1. Load and line regulation are specified at constant junction temperature. Change in V into account separately. Pulse testing with low duty is used.
TJ =+25°C
O
O
-7.0VV V
= -10V, 1.0mA ≤ I
I
-20V, 1.0mA IO ≤ 40mA -4.75 - -5.25 V
I
TJ =+25°C-2.05.5
Q
Q Q
N
= +125°C--6.0
T
J
-8V V
1.0mA I
≥ -20V - - 1.5 mA
I
O
TA = +25°C,10Hz ≤ f ≤ 100kHz - 30 - µV f = 120Hz, -8V V
T
= +25°C
J
TJ = +25°C-1.7-V
D
1.0mA I
1.0mA I
70mA -4.75 - -5.25 V
O
40mA - - 0.1 mA
-18V
I
100mA - 20 60 mV
O
40mA - 10 30 mV
O
mA
41 60 - dB
due to heating effects must be taken
O
2
MC79LXXA/LM79LXXA
Electrical Characteristics (MC79L08A)
(VI = -14V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤T
(Continued)
+125°C, unless otherwise specified)
J
Parameter Symbol Conditions Min. Typ. Max. Unit
Output Voltage V
Line Regulation(Note1) ∆V
Load Regulation (Note1) ∆V
Output Voltage V
Quiescent Current I
Quiescent Current Change
With Line With Load 1.0mA ≤ I
I
Output Noise Voltage V Ripple Rejection RR Dropout Voltage V
TJ = +25°C -7.7 -8.0 -8.3 V
O
≥ -23V - - 175 mV
I
≤ 100mA - - 80 mV
o
≤ 40mA - - 40 mV
o
O
O
O
TJ = +25°C
TJ = +25°C
-10.3V V V
= -14V, 1.0mA ≤ I
I
-23V, 1.0mA Io ≤ 40mA -7.6 - -8.4
I
-10.3V V
-12V VI ≥ -23V - - 125 mV
1.0mA I
1.0mA I
70mA -7.6 - -8.4
o
Tj = +25°C--6.0
q
T
= +125°C--5.5
j
-11.7V V
Q
Tj = +25°C,10Hz ≤ f ≤ 100kHz - 50 - µV
N
f = 120Hz, -11V ≥ V T
= +25°C
j
Tj = +25°C-1.7-V
D
≥ -23V - - 1.5 mA
I
≤ 40mA - - 0.1 mA
o
-21V
I
39 55 - dB
V
mA
Note:
1. Load an d lin e re gul ation ar e sp ecifi ed at con sta nt ju nct ion t empe rat ure . Chan ge i n V into account separately. Pulse testing with low duty is used.
due to heating effects must be taken
O
3
MC79LXXA/LM79LXXA
Electrical Characteristics(MC79L12A)
(VI = -19V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤T
(Continued)
+125°C, unless otherwise specified)
J
Parameter Symbol Conditions Min. Typ. Max. Unit
Output Voltage V
Line Regulation (Note1) ∆V
Load Regulation (Note1) ∆V
Output Voltage V
Quiescent Current I
Quiescent Current Change
With Line ∆I With Load ∆I
Output Noise Voltage V Ripple Rejection RR Dropout Voltage V
TJ = +25°C -11.5 -12.0 -12.5 V
O
≥ -27V - - 250 mV
I
≤ 100mA - - 100 mV
O
≤ 40mA - - 50 mV
O
O
O
O
TJ = +25°C
TJ = +25°C
-14.5V > V V
= -19V, 1.0mA ≤ I
I
> -27V, 1.0mA IO ≤ 40mA -11.4 - -12.6 V
I
-14.5V V
-16V VI ≥ -27V - - 200 mV
1.0mA I
1.0mA I
70mA -11.4 - -12.6 V
O
TJ = +25°C--6.0
Q
T
= +125°C--6.5
J
-16V V
Q
1.0mA I
Q
TA = +25°C,10Hz ≤ f ≤ 100kHz - 80 - µV
N
f = 120Hz, -15VV T
= +25°C
J
TJ = +25°C-1.7-V
D
≥ -27V - - 1.5 mA
I
≤ 40mA - - 0.1 mA
O
-25V
I
37 42 - dB
mA
Note:
1. Load and line regulation are specified at constant junction temperature. Change in V into account separately. Pulse testing with low duty is used.
due to heating effects must be taken
O
4
Loading...
+ 8 hidden pages