Fairchild Model 17 Installation, Operation And Maintenance Instructions

Page 1
Fairchild Model 17 Vacuum Regulator
Installation, Operation and Maintenance Instructions
Figure 1. Model 17 Outline Dimension
General Information
The Model 17 is a high accuracy vacuum regulator that provides uniform vacuum regulation independent of vacuum supply changes and flow demand.
Specifications
Flow Capacity 3 scfm @ 25” Hg Supply, 10” Hg setpoint
Sensitivity 1/8” W. C.
Ambient Temperature Limits -40 F to + 200°F, (-40°C to + 93.2°C)
Vacuum Supply Effect Less than 0.1” Hg for 10” Hg change in vacuum supply
Materials of Construction Body & Housing . . . . Aluminum
Trim . . . . . . . . . . . . . . . Brass, Zinc Plated Steel
Elastomers . . . . . . . . . Nitrile
Page 2
Installation
Flow
Process
Vacuum Pump
OUT
IN
Maintenance
Clean all pipelines to remove dirt and scale before installation.
Apply a minimum amount of pipe compound to the male threads of the fitting only. Start with the third thread back and work away from the end of the fitting to avoid the possibility of contaminating the regulator. Install the regulator in the air line.
The inlet and outlet connections are labeled on the un­derside of the regulator with the arrows pointing in the direction of the flow. Tighten connections securely.
Avoid undersized fittings that will limit the flow through the regulator and cause a pressure drop downstream. For more information, see Figure 1. “Outline Dimen­sions”.
NOTE: Oil free air must be applied to the
regulator. Use a filter to remove dirt and entrained liquid in the air line ahead of the regulator. If an air line lubricator is used, it MUST be located downstream of the regulator, to avoid interference with regulator performance.
To clean the Model 10V, use the following procedures:
1. Before assembly, shut off the valve that is supplying air to the regulator. This is to prevent air from escaping. It is not necessary to
remove the regulator from the air line.
2. Remove the two Screws from the bottom of the unit.
3. Pull out the Inner Valve Assembly. Wash the Seat on the Inner Valve Assembly carefully.
4. Wipe off any particles that may be attached to rubber Seat Ring in Body.
5. Replace the assembly carefully.
6. Keep the vent hole in the Bonnet clear for proper regulator operation. Lubricate the adjusting screw with Molycote “G”.
NOTE: Avoid such solvents as acetone,
carbon tetrachloride and trichorethylene.
Trouble-Shooting
Problem Solution
Leakage Body Screws
Tightness. Diaphragms.
Valve Seal Ring Chatter lubrication.
LEGAL NOTICE
The information set forth in the foregoing Installation, Operation and Maintenance Instructions shall not be modified or amended in any respect without prior written consent of Fairchild Industrial Products Company. In addition, the information set forth herein shall be furnished with each product sold incorporating Fairchild's unit as a component thereof.
Figure 2. Model 17 Installation Diagram
IS-1000017
Litho in USA
Rev 0108