Fagor QVR-3G N, QVR-1G N, QVF-1 N, QVR-2 N, QVF-1G N Manual Instructions

...
MARCH 2017
REFRIGERATORS AND FREEZERS
Manual Instructions
Manual instructions
Installation and Operation
Manual de instrucciones
Uso y mantenimiento
ES
EN
DOCUMENT CODE: 602305M0063
2
fagorindustrial.com
INDEX
ENGLISH
SPECIFICATION CHART ...........................................................................................................................4
MACHINE INTRODUCTION ..........................................................................................................................5
1.1 Introduction to machine & models .......................................................................................5
1.2 Important safety information ..................................................................................................5
INSTALLATION .................................................................................................................................................6
2.1 General information .....................................................................................................................6
2.2 Transport, handling, unpacking, location ......................................................................6
2.3 Intended use and restrictions ...............................................................................................7
2.4 Manufacturer’s identification label description .........................................................7
2.5 Installation and assembly ........................................................................................................8
2.6 Connections (electrical) ............................................................................................................8
OPERATION........................................................................................................................................................8
3.1 General information .....................................................................................................................8
3.2 Control panel description .......................................................................................................8
3.2.1 Electronic Control...............................................................................................................8
3.3 Machine settings and programs ............................................................................................9
MAINTENANCE .............................................................................................................................................. 10
4.1 General safety rules................................................................................................................ 10
4.2 Machine cleaning and maintenance routine ................................................................. 10
4.2.1 Cleaning the Condenser Coil ....................................................................................... 10
4.2.2 Cleaning the Gasket .......................................................................................................... 11
4.2.3 Draining the Unit ................................................................................................................ 11
4.3 Machine disposal ........................................................................................................................ 11
TROUBLESHOOTING CHART .................................................................................................................. 12
5.1 Troubleshooting chart ............................................................................................................ 12
3
fagorindustrial.com
ESPAÑOL
INTRODUCCION ............................................................................................................................................ 13
1.1 Introducción a los equipos y modelos ........................................................................... 13
1.2 Información de seguridad ...................................................................................................... 13
INSTALACION ................................................................................................................................................ 14
2.1 Información General ................................................................................................................. 14
2.2 Transporte, manejo, desempaque y localización ...................................................... 14
2.3 Uso y restricciones ................................................................................................................... 15
2.4 Placa de identificación del Fabricante .......................................................................... 15
.......................................................................................................................................................................... 15
2.5 Instalación y Ensamble ........................................................................................................... 16
2.6 Conexiones ...................................................................................................................................... 16
OPERACION .................................................................................................................................................... 16
3.1 Información General ................................................................................................................. 16
3.2 Descripción del panel de control ..................................................................................... 16
3.2.1 Control electronico ......................................................................................................... 16
3.3 Configuraciones del Equipo ................................................................................................. 17
4.1 Reglas de seguridad general .............................................................................................. 18
4.2 Rutina de limpieza y mantenimiento del equipo ........................................................... 18
4.2.1 Limpiando el condensador ............................................................................................. 18
4.2.2 Limpieza del empaque plástico ..................................................................................... 19
4.2.3 Drenado ................................................................................................................................... 19
4.3 Disposición del equipo ............................................................................................................. 19
SOLUCIONANDO PROBLEMAS ............................................................................................................. 20
5.1 Solucionando problemas........................................................................................................ 20
ELECTRIC DIAGRAM / DIAGRAMA ELECTRICO .............................................................................. 21
ANEXOS ............................................................................................................................................................ 24
4
fagorindustrial.com
SPECIFICATION CHART
PREMIUM LINE “N”
NOTES:
__________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ _______________________________________________________________________________________
MODEL
HP
DIMENSIONS
(in) mm
VOLTAGE
(V)
AMP.
(A)
REFRIGERANT
CHARGE
TIPO
REFRIG.
BTUS/
HR
WEIGHT
(LB)
QVR-1 N
1/4
(17 x 31 x 80)
685 x 675 x 1825
115 220
5.0
3.1
11.3 Oz.
R-134a
1660
264 lb
QVR-1G N
1/3
(37 x 27 x 84)
1105 x 812 x 1981
115 220
6.6
3.5
11.3 Oz.
R-134a
2104
440 lb
QVR-2 N
1/3
(55 ¼ x 27 ¾ x 84 ½)
1371 x 812 x 1981
115 220
6.9
3.5
13.4 Oz.
R-134a
2104
476 lb
QVR-2G N
1/3
(17 x 31 x 80)
685 x 675 x 1825
115 220
5.2
3.9
13.4 Oz.
R-134a
1660
264 lb
QVR-3 N
1/2
(27 x 31 x 80)
685 x 812 x 1981
115 220
5.8
3.9
22.2 Oz
R-134a
1666
280lb
QVR-3G N
1/2
(37 x 27 x 84)
1105 x 812 x 1981
115 220
7.2
3.9
22.2 Oz
R-134a
2104
440 lb
QVF-1 N
3/4
(55 ¼ x 27 ¾ x 84 ½)
1371 x 812 x 1981
115 220
9.8
4.5
16.6 Oz.
R-134a
2104
476 lb
QVF-1G N
3/4
(17 x 31 x 80)
685 x 675 x 1825
115 220
9.8
4.5
16.6 Oz.
R-404A
2493
280 lb
QVF-2 N
3/4
(27 x 31 x 80)
685 x 812 x 1981
115 220
11.5
6.5
21.5 Oz.
R-404A
2493
280 lb
QVF-2G N
3/4
(55 ¼ x 27 ¾ x 84 ½)
1371 x 812 x 1981
115 220
11.5
6.5
21.5 Oz.
R-404A
3644
456 lb
QVF-3 N
1
(72 x 27 ¾ x84 ½ ) 2060 x 812 x 1981
115 220
16.0
9.5
33.2 Oz.
R-404A
*
*
5
fagorindustrial.com
MACHINE INTRODUCTION
1.1 Introduction to machine & models
FAGOR Reach Ins feature dual and triple paneL glass door, contributing to energy efficiency and savings. Standard digital control displays precise temperature for customer convenience while LED lights showcase the best out of your products.
Details make this line unique .
New enhanced digital controller and display. Digital controller refrigerators to keep food quality for longer period of
time.
Door alarm and user friendly controls to adapt to different enviroments. Factory balanced refrigeration system, environmentally friendly R-134a /
R-404A.
Stainless steel coved corner floor to meet NSF requirements.
4” castors and door locks standard.
Recessed door handles.
1.2 Important safety information
DANGER: Power must be turned off and disconnected from the power source whenever performing maintenance, repair or cleaning the condensing unit.
If machine still running when power is off, disconnect power at the circuit breaker before unplugging the machine. WARNING: Machine and compressor warranties are void if failure is due to improper electrical installation. Do not introduce hot foods, chemical or corrosive products, drugs, or open beverage bottles.
Notes
____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________
6
fagorindustrial.com
INSTALLATION
2.1 General information
2.2 Transport, handling, unpacking, location.
2.3 Intended use and restrictions.
2.4 Manufacturer’s identification label description.
2.5 Installation and assembly.
2.6 Connections (electric, gas, water)
2.1 General information
You can find in you equipment the following symbols, or stickers to identify some type of warnings or useful information about your equipment.
2.2 Transport, handling, unpacking, location
Upon receiving your new FAGOR REACH IN, check the package and the machine for any damages that may have occurred during transportation. Visually inspect the exterior of the package, if damaged, open and inspect the contents with the
carrier. Any damage should be noted and reported on the delivering carrier’s
receipt.
In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier immediately. Notification should be made verbally as well as in written form. Request an inspection by the shipping company of the damaged equipment. Retain all crating material until inspection has been made. Contact the dealer through which you purchased the unit.
Check the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
7
fagorindustrial.com
2.3 Intended use and restrictions
FAGOR equipment is not designed for personal, family, or household purposes, and its sale for such purposes is not intended. In the event the equipment is so used, this warranty shall be null and void, and the equipment is so used, this warranty shall be null and void, and the equipment shall be deemed to have been sold “as is-where is” without any warranty of any kind, including without limitation any warranty of title, non-infringement, merchant-ability or fitness for a particular purpose.
The equipments are conforms to UL and NSF- 7 standards.
If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual.
2.4 Manufacturer’s identification label description
The data plate is located inside the cabinet, near the top front, left corner. Under no circumstances should the data plate be removed from the unit. The data plate is essential to identify the particular features of your machine and it is of great benefit to installers, operators, and maintenance personnel. It is recommended that, in the event the data plate is removed, you copy down the essential information in this manual for reference before installation. Removal of data plate will void the warranty.
Model
Refrigerant
Type
Electricals
Serial Number
(8 digits and ends in “M”)
Code
Serial Number
8
fagorindustrial.com
2.5 Installation and assembly
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the unit and contents. For the most efficient operation, be sure to provide good air circulation inside and outside of the unit.
INSIDE CABINET The first cleaning must be made when you unpack the unit and before switching it on. Clean it with water and a mild detergent. When it is clean and dry, insert the accessories in the appropriate places, for the best use of the user.
OUTSIDE CABINET Be sure the unit has good air circulation around it. Avoid hot corners and locations near stoves and ovens. It is recommended the unit be installed no
closer than 2” from any wall. The place where the refrigerator is placed must be
open and clean, avoiding that de fan of the condensing unit absorbs materials which are deposited then into the condenser blades and coil, which can produce failures.
The unit should not be installed under ambient temperatures higher than 100 °F.
If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a malfunctioning of the unit.
2.6 Connections (electrical)
Refer to the amperage data in this manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source. Verify correct incoming voltage according to the Data Plate information. The data plate in located inside the unit, near the top front left corner. Under any circumstances should the data plate be removed from the unit. The data plate is essential to identify the particular features of your unit and is of great benefit to installers, operators and maintenance personnel. It is recommended that, in the event the data plate is removed, you copy down the essential information in this manual for reference before installation. A protected circuit of the correct voltage and amperage must be run for connection of the supply cord. Unit must be grounded and connected in accordance with NEC Article 422 Appliances.
OPERATION
3.1 General information.
3.2 Control panel description.
3.3 Machine settings and programs.
3.1 General information
Good air flow inside the cabinet is critical. Do not block air flow to the fans. Allow three inches of space along the front, back, and sides.
3.2 Control panel description
3.2.1 Electronic Control
After connecting your unit, turn ON rocker switch located next to the controller. The display will light up showing the temperature inside the unit. Also, the compressor and fan icons will flash for a period of three minutes. After this delay the unit will start cooling. Verify you don't have any alarms on the temperature controller. If after you turn ON the equipment the controller shows the alarm icon or an error code, call for technical service. They will help you fix the problem.