Factory Direct Hardware 32314 User Manual

Metris
31436XX1
Metris
31446XX1
Focus
31732XX1
Focus
31733XX1
Talis
32313XX1
Talis
32314XX1
Installation Instructions / Warranty
2
Trim, 3- and 4-Hole Roman Tub Sets
Installation Considerations
The 4-Hole Roman Tub Set trim kits require rough 06646000. The 3-Hole trim kits require rough
06607000. The rough valves are not included.
The rough must be installed and the mounting surface complete and made watertight before instal­lation of this trim kit.
The elbow for the handshower incorporates a check valve to prevent back siphonage. This check valve should be removed and inspected yearly.
The flow rate of the handshower is 2.5 gpm.
The water must be shut off at the main before beginning installation.
31436XX1 31446XX1
3
31732XX1 31733XX1
32313XX1 32314XX1
4
Installation - 3-Hole Trim Kits
If you are using a 4-Hole set, please turn to page 6
Install the Handles
Remove the plaster shields from the hot and cold valves and the spout tee.
Assemble the Spout
Remove the brass plug from the tee.
Install the handle escutcheons.
Install the white plastic snap connectors and the screws.
Push the handle down firmly over the snap connectors.
5
Push the spout sealing ring firmly into the spout tee.
Install the spout escutcheon.
Press the spout over the spout tee. Install and tighten the set screw with a 3 mm Allen wrench.
CAUTION: do not overtighten the set screw or the o-rings on the diverter will deform, which will cause a leak.
Turn on the water and check all connections for leaks.
Loading...