EN
Dear User,
Thank you for purchasing this digital torque-angle adaptor.
This manual will help you to use the many features of your new digital
torque-angle adaptor. Before operating the torque adaptor, please read
this manual completely, and keep it nearby for future reference.
MAIN FEATURES
• Digital torque-angle value readout
• +/-2° ( rotating 90° at speed of 30°/sec) for angle accuracy
• +/- 3% or +/- 4% for torque accuracy
• CW and CCW operation
•
Buzzer and LED indicator for the 9 pre-settable target torques or angles
• Five Units Selectable (N.m, ft-lb, in.lb, kg.cm, degree)
• 50 data memory for recall and joint torque-angle auditing
• Auto Sleep after about 2 minutes idle
• Both AAA and rechargeable batteries are compatible
NAMES AND FUNCTIONS OF PARTS A
1. LED Indicator 7. Memory Number
2. Buzzer 8. Buttons
3. LCD Display 9. Communication Port
4. Torque/Angle Value 10. Extension bar
5. Units 11. Battery cover
6. Peak/Track Mode
4
5
3
A
1
2
8
10
11
6
7
9
B
SPECIFICATIONS
Torque Accuracy *1 CN / CW :±3% CCW :±4%
Angle Accuracy *2 +/- 2° ( rotating 90° at speed of 30°/sec)
Measured Angle Range
Data memory size 50
PC Connectivity *3 No
Pre-setting No 9 sets
Bright LED 12 LED / 2 Red+10 Green
Torque Operation Mode Peak Hold / Track
Unit selection N.m, ft-lb, in-lb, kg.cm, degree
Button 5
Battery AAA x 2
Battery Life *4 (Continuous operation) 24 hrs.
Battery Life *4 (Standby) 1 Year
Operating Temperature
Storage Temperature
Humidity Up to 90% non-condensing
Drop Test 1 m
Vibration Test *5 10 G
Life time *6 10000 cycle
Environmental test *7 Pass
Electromagnetic compatibility test *8 Pass
E.506-135S - E.506-200S - E.506-340S
1° ➞ 999.0°
-10°C ➜ 60°C
-20°C ➜ 70°C
Note: *1: The accuracy of the readout is guaranteed from 20% to 100% of
maximum range +/- 1 increment. For maintaining accuracy, calibrate the
adaptor at regular intervals (1 year recommended).
*2: The angle accuracy is guaranteed at ±2° when rotating adaptor
to 90° at speed of 30°/sec.
*3:
Use a special designed cable (accessory) to upload record data to PC.
*4:
Use two AAA batteries (Tested condition: Toshiba carbon-zinc battery)
*5: Horizontal and vertical test.
*6: One cycle means turning the torque adaptor from 0 N.m to
maximum torque and back to 0 N.m.
*7: Environmental test: a. Dry heat e. Impact (shock)
b. Cold f. Vibration
c. Damp heat g. Drop
d. Change of temperature
*8: Electromagnetic compatibility test:
a. Electrostatic discharge immunity (ESD) b. Radiated susceptibility
c. Radiated emission
BEFORE USING THE ADAPTOR
BATTERY INSTALLATION B
• Loosen the screw of the battery cover.
• Insert two AAA batteries matching the -/+ polarities of the battery to
the battery compartment.
•
Put on the battery cap and rotate it tightly according to the following fi gures.
POWER ON AND AUTO ZERO RESET
• Let the adaptor be sat without touching it
• Gentlely press
to power on.
• Auto zero-reset will be processed fi rst.
• The adaptor will be started in torque or angle mode.Which mode will be
started depends on in which mode the adaptor is powered-off last time.
• In torque mode, fi rst is torque zero-reset and then a target torque screen
will show.
• In angle mode, it fi rst do several seconds of angle- zero-reset and then a
target angle screen will show.(Very important issue: See attention)
• If it takes too long in angle reset, press
Press
Press
Torque zero reset
Torque zero reset
will perform reset again.
N.m
M
T
Current target torque
Current target angle
M
ATTENTION:
1. If
is appeared, refer to “ERROR MESSAGE”.
2. IMPORTANT!
During angle reset, keep the adaptor still and never shake, vibrate or even
touching the adaptor.
If the adaptor is moving again and again, the zero reset will not stop.
Finally,
will be shown.( Refer to “ERROR MESSAGE”)
AUTO POWER OFF
The adaptor will auto power off after about 2 minutes idle for power saving.
CAUTIONS:
During communication period (
appears), the auto power-
off function is disabled.
• Press for zero reset.
• Usually press
to zero reset
Press
the digital torque-angle adaptor before using the adaptor.
It will guarantee a better accuracy.
• In angle mode, please keep the adaptor steady without any disturbance
and press to do zero-reset.
• In torque mode, if an external force is applied to the torque adaptor
during zero-reset period, an initial torque offset error will occur.
HARDWARE RESET
• To do haraware reset, remove battery and re-install it.
• If the adaptor does not function normally or
appeares,
please go through the reset process to reset the adaptor.
ERROR MESSAGE
LOW VOLTAGE INDICATOR
If the battery voltage is too low, the adaptor will display a battery
symbol and then turn off. Replace batteries.
M
Low battery indicator
When
shows during power-on process, it means this
adaptor has ever been applied more than 110% of torque of the
spec.The accuracy of torque may be lost.
In angle mode, if the adaptor does not reset successfully for a period
of time,
will be shown. Press to do zero-reset
again. Notice that during resetting process, never vibrate or shake
the adaptor. Keep it rest.
shows that the adaptor does not work functionally,
please do hardware reset. Refer to “HARDWARE RESET”.
In angle mode, iff the adaptor rotates too fast,
shown.Do press
to zero reset the adaptor.
will be
OPERATION
FAST GETTED START
➜ Press
➜ Target torque or angle will be shown.
➜
and then press
➜
➜
➜ Start to rotate adaptor.
➜ Watch out the warning LED, sounds and LCD to stop rotation.
T-mode torque operation
➜ In T-mode, LCD displays the current torque value.
➜ After release force, the LCD value will return to O.
P-mode torque operation
➜ In P-mode, LCD displays the maximum torque value.
➜ After release force, the LCD shows the catched maximum value. (fl ashing)
➜ Now press
Angle operation
➜ In angle mode, LCD displays the angle rotated after the reaching over 5% of
➜ Now press
1- INSTALL THE ADAPTOR AND POWER ON
● Press to power on the adaptor.
2- NO APPLING FORCES ON ADADAPTOR
to power on. No appling forces on adaptor.
Press
to select the torque unit or “ ° ” (angle mode)
to set target value
Or press
to select the pre-set target values
Press
to reset adaptor.(suggested)
to record maximum torque value, or press to clear it.
the rated maximum torque.
to record angle value, or press to clear it.
.
.
.
E.506-135S
E.506-200S
E.506-340S
www.facom.com
E.506-135S
903605
(N.m) (‘‘)
0,1 1/2
0,1 1/2
0,1 1/2
Instruction manual
E.506-200S
903613
Min. ➞ Max.
6,8➞135
10➞200
17➞340
E.506-340S
903621
(N.m) (mm)
80
80
80
NUen-E.506/0811

3- TARGET TORQUE OR ANGLE WILL BE SHOWN
N.m
Without
appling force
M
T
Target
torque or angle
M
4- SET TARGET TORQUE OR ANGLE
●
Press to select the torque unit (torque mode) or ‘‘°’’ (angle mode).
● Then press or to set targuet value.
● Note that the target value will be saved automatically with the
current M number discarding torque or angle.
●
Another way is to press to select the pre-set target value (M1~ M9)
EX. Select units
N.m
N.m
M
T
in.lb
In.lb
M
T
ft.lb
Ft.lb
M
T
kg.cm
M
T
Kg.cm
M
° (angle)
● if is shown as press or .It indicates
that the key is locked.
Please refer to “Key Lock/Unlock” to un-lock keypad.
EX. Set targets
N.m
N.m
M
T
or
N.m
M
T
M
T
M
T
M
T
EX. Using the pre-set targets
N.m
M
T
N.m
M
T
M
T
5- ZERO-RESET ADAPTOR
● Press to zero-reset the adaptor. (suggested)
● Refer to ‘‘POWER ON AND AUTO ZERO RESET’’
and ‘‘ZERO RESET’’.
Press
TORQUE ONLY
6- CHEK P/T MODE OF TORQUE
●
Refer to ‘‘P/T MODE SELECTION’’ to set P or T-mode operation of torque.
Defi nition
T-mode torque view
1. In T-mode, if a force is applied on adaptor, LCD displays and tracks
the current torque value.
2. After releasing force, the LCD value will return to target setting view.
P-mode torque view
N.m
M
T
1. In P-mode, LCD displays the maximum torque value.
2. After releasing force, the LCD shows the catched maximum value.
(fl ashing)
N.m
M
P
7- START TO ROTATE ADAPTOR
●
Rotate the adaptor clockwise or counter-clockwise
8-
WATCH OUT THE WARNING LED, SOUNDS AND LCD TO STOP ROTATION
● There are 12 LEDs to indicate the current torque or angle reaching 80%,
85%, 90%, 95%, 97.5% and 99.5% of target torque/angle.
Red Green
99.5% 97.5% 95% 90% 85% 80%
Angle-mode
●
In angle-mode, after releasing force, the LCD shows the maximum angle and
the maximum torque (alternatively).
●
Pressing will clear the maximum angle and go back to show the target angle.
●
Pressing will record the maximum angle, then clear it and go back to show the target tangle.
Maximum angle
and torque
(alternatively)
11- BACK TO STEP 2 FOR NEXT OPERATION
● There is also a buzzer to indicate the reaching level of target value.
Interval sound means it reaches over 80% and long sound means it reaches
over 99.5% of target value.
((..((..((.. ..))..))..))..))
(((((((((.. ..))))))))))
➜ over 80 %
➜ over 99.5 %
VISIT SETUP MENU
●
From the target torque/angle screen, long press to go into setup
menu. Continuously press
angle-operation menu,key lock menu, record menu, record clear-all menu,
operation count menu and communication menu. Finally press
9-
TORQUE / ANGLE VALUE WHEN ROTATES
skip out the setup menu and go back to the target torque/angle screen.
T-mode Torque value
● In T-mode, if a force is applied on adaptor, LCD displays and tracks the
current torque value.
● After releasing force, the LCD value will return to target setting view.
Apply 13.5 N.m
Release force
N.m
T
Current torque value
N.m
M
T
Current target
torque or angle
P-mode Torque value
● In P-mode, LCD displays the maximum torque value.
● After releasing force, the LCD shows the maximum value. (fl ashing).
Apply 13.5 N.m
12.0 N.m 24.48 N.m
N.m
P
N.m
P
Release force
N.m
P
N.m
P
Angle value
●
In angle mode, LCD displays the angle rotated. The angle is counted after the
rotation torque has been reaching over 5% of the rated maximum torque.
● After releasing force, the LCD shows the maximum angle and the
maximum torque.(alternatively)
EX. For a 30.00 N.m adaptor, 5% is 1.5 N.m
No force Release force1.5 N.m
10- SAVE
TORQUE / ANGLE VALUE OR CLEAR MAXIMUM VALUE
P-mode
●
In P-mode, after releasing force, the LCD shows the maximum value. (fl ashing).
●
Pressing will clear the maximum torque and go back to show the target torque.
●
Pressing will record the maximum torque, then clear it and go back to show the target torque.
N.m
P
Maximum torque
Show rec (record) and its number
Continuously
applying force
MM
Maximum angle and torque
N.m
P/T MODE SELECTION
● Visit the P/T mode menu, press or to select the Peak-
hold or Track mode of torque operation.
● Continuously pressing will skip out the setup menu and go back
to the target torque/angle screen.
Target torque
Target torque
N.m
M
T
N.m
M
T
Show rec (record) and its number
N.m
M
T
N.m
Target angle
Target angle
can visit the P/T mode menu, torque-unit-in-
Long Press
M
P/T mode menu
Torque-unit-in-angle
operation menu
Key lock menu
Re-cord menu
Record clear-all menu
Operation count menu
Communication menu
T
or
P
M
M
again to
P
N.m
SELECT TORQUE UNIT IN ANGLE OPERATION
● Visit the torque-unit-in-angle-operation menu,
press or to select the torque unit during angle rotation.
● Continuously pressing will skip out the setup menu and go back
to the target torque/angle screen.
N.m
in.lb
ft.lb
kg.cm
KEY LOCK/UN-LOCK
● Visit the key lock menu, press or to select the key lock on
or off.
● Continuously pressing will skip out the setup menu and go back
to the target torque/angle screen.
Auto change
Lock on / off selection
VIEW DATA RECORD
● Visit the record menu, press or to select the data number
and view it.
● If no record exists, will be shown.
N.m
● Continuously pressing will skip out the setup menu and go back
to the target torque/angle screen.
Press or to select data
CLEAR A SINGLE RECORD
● Visit the record menu
● Press or to select the data number you want to delete.
● Press twice to delete the current data.
(
will be shown)
● If press once, will be shown. If you want to
abandon, just press to skip out this menu.
● Continuously pressing will skip out the setup menu and go back
to the target torque/angle screen.
Press or
to select data
Press
Press
Abandon
CLEAR ALL RECORDS
● Visit the record clean-all menu
●
Press twice to delete the all record data. ( will be shown)
● If press once, will be shown. If you want to
abandon, just press
to skip out this menu.
● Continuously pressing will skip out the setup menu and go back
or
or
or
to the current target angle screen.
Press
Press
Press
Abandon
VIEW OPERATION COUNTS
● Visit the operation counts, the operation counts will be shown.
● Operation counting record counts every time the adaptor has been
used over 60% of maximum torque.
This record is not erasable until re-calibration.
● The feature will count up to 65,000 measurements.
● The following fi gure means the recorded count is 10025.
● Continuously pressing will skip out the setup menu and go back to
the target torque/angle screen.
EX. 10025 times
MAINTENANCE AND STORAGE
ATTENTION:
One-year periodic recalibration is necessary to maintain accuracy.
Please contact your local dealer for calibrations.
CAUTION:
1- Over-torquing (110% of Max. torque range) could
cause breakage or lose of accuracy.
2- Do not shake violently or drop adaptor.
Do not expose this adaptor to dust or sand as this could cause serious damage.
Keep a spare battery on hand when going on a long trip or to cold areas.
Sweat, oil and water can prevent a battery’s terminal from making
Press
3- Do not leave this adaptor in any place exposed to excessive heat,
humidity, or direct sunlight.
4- Do not use this apparatus in water.(it is not waterproof)
5- If the adaptor gets wet, wipe it with a dry towel as soon as possible.
The salt in seawater can be especially damaging.
6- Do not use organic solvents, such as alcohol or paint thinner when
cleaning the adaptor.
7- Keep this adaptor away from magnets.
8-
9- Do not apply excessive force to the LCD panel.
BATTERY MAINTENANCE
1- When the adaptor is not going to be used for an extended period of
time, remove the batteries.
23- Do not mix battery types or combine used batteries with new ones.
4-
electrical contact. To avoid this, wipe both terminals before loading a battery.
5- Dispose of batteries in a designated disposal area.
Do not throw batteries into a fi re.