READ AND SAVE THESE INSTRUCTIONS BEFORE YOU
START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium setting.
b)AlwaysturnhoodONwhencookingathighheatorwhenambeingfood(i.e.Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan
orlter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
a)SMOTHERFLAMESwithaclose-ttinglid,cookiesheet,ormetaltray,thenturnofftheburner.
BECAREFULTOPREVENTBURNS.IftheamesdonotgooutimmediatelyEVACUATE
AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN - You may be burned. c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will
result. d) Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. Thereissmallandcontainedintheareawhereitstarted. 3. Theredepartmentisbeingcalled. 4. Youcanghttherewithyourbacktoanexit.
* Based on "Kitchen Firesafety Tips" published by NFPA
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switched on acciden­tally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. InstallationWorkAndElectricalWiringMustBeDoneByQualiedPerson(s)InAccor-
dance With All Applicable Codes And Standards, Including Fire-Rated Construction.
2. Sufcient air isneeded for propercombustion and exhaustingof gases through
theue(chimney) of fuelburningequipmentto prevent backdrafting.Followthe
heating equipment manufacturer's guideline and safety standards such as those
publishedby the National Fire ProtectionAssociation(NFPA),andtheAmerican SocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE),and
the local code authorities.
3
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED
MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop. This hood has been approved by UL at this distance from the cooktop. This minimum clearance may be higher depending on local building codes. For gas cooktops and combination ranges, a minimum of 30" is recommended and may be required. The maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts. MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements.
• Venting system MUST terminate outside the home.
DO NOT terminate the ductwork in an attic or other enclosed space.
DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
DO NOT obstruct the ow of combustion and ventilation air.
• Failure to follow venting requirements may result in a re.
WARNING
!
Cold Weather installations
An additional back draft damper should be installed to minimize backward cold air ow and a
nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house.
VENTING REQUIREMENTS
Determine which venting method is best for your application. Ductwork can extend either through
the wall or the oor.
The length of the ductwork and the number of elbows should be kept to a minimum to provide ef-
cient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or oor
opening around the cap.
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly reduces performance.
Make sure there is proper clearance within the wall or oor for exhaust duct before making cutouts.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a support­ing frame must be constructed.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
CAUTION-Toreduceriskofreandtoproperlyexhaustair,besuretoductairoutside–Do
not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
4
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.
• Check with a qualied electrician if you are in doubt as to whether the rangehood is
properly grounded.
• Failure to follow electrical requirements may result in a re.
WARNING
!
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
5
RANGEHOOD DIMENSIONS
3
11/16
25
1/4
“ - 31
1/4
4
3/4
3/16
16“
27
7/16
1/4
4“
9
13/16
13
1/16
25
9/16
“ - 31
9/16
13
1/16
30” - 36”
6
MAIN PARTS
Components
Ref. Qty. Product Components
1 1 Hood Canopy complete with: Controls, Light, Filters. 3 1 Electric unit. 4 1 Top Frame
6 1 Duct Collar 10" duct collar used
with Remote Blowers
Ref. Qty. Installation Components
7.1 2 Lower Fixing Bracket
7.2 2 Top Side Fixing Bracket
7.3 2 Top Front Bracket 12a 16 Screws 1/8" x 3/8" 12b 6 Screws 3/16" x 5/16" 12c 8 Screws 3/16" x 9/16"
Qty. Documentation
1 Instruction Manual
10" duct collar used with Remote Blowers
AvailableAccessories(Purchasedseparately)
Recirculation Kit - sku # DUCTSCIR Recirculation Vent Kit - Activated Charcoal Filter - FILTERSCIR Internal Blower model - IBDD600-B Remote Blower model - RB900, RB1200 (WIREBOX for Remote Blower included) Wireless Remote Control - REMCTRL Wiring box for Remote Blower - WIREBOXSCLX
Parts needed
- 6" Round Metal ductwork .

5
12b
12b
7




1
2
The minimum distance between the opening for the cooktop and the one for the hood must be of at least 1 3/16" - 1 15/16" according to the strength of the material used for the working top.
• Insert the Hood Canopy from below into the countertop cutout, drilled as described above.
Installation Instructions
Cutout Dimensions
INSTALLATION
This Hood is set up to be fitted inside the kitchen unit in:
Ducting version: Evacuation to the outside.
Sequence of operations - Installation
Drilling the Support Surface and Fitting the Hood
Connections
Functional Check
Disposal of Packaging
Drilling the Support Surface
X
812
Y
X
Inserting the Hood Canopy into the countertop from below
• Insert the Brackets
7.2, as indicated in
the gure, into the slots provided and x
them with the screws 12a provided.
• Center the Hood Canopy with respect to the Cooktop slot.
• Using the 2 screws 12c provided, secure the Hood Canopy to the countertop and remove the supports.
Warning:
If the countertop is made from a material that does not allow the screws 12c to be inserted, use a small amount of silicone to glue the Brackets 7.2 to the top and allow it to dry completely before proceeding with installation.
• With the aid of a support, lift the Hood Canopy until the front comes out of the countertop.
FOR YOUR SAFETY: WARNING Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Hood X Y
30" 25 15/16" 4 5/16" 36" 31 15/16" 4 5/16"
8
12a
7.1
12a
7.1
Fixing the Lower Brackets
3
• Insert the Brackets 7.2, as
indicated in the gure, into the slots provided and x them
with the screws 12a provided.
Inserting the Hood Canopy into the countertop from above
• Insert the Hood Canopy into the countertop, drilled as described above.
• Center the Hood Canopy with respect to the cooktop slot.
• Secure the Hood Canopy with the 2 screws 12c provided.
Warning:
If the countertop is made from a material that does not allow the screws 12c to be inserted, use a small amount of silicone to glue the Brackets 7.2 to the top and allow it to dry completely before proceeding with installation.








4
Securing the Lower Brackets
• Screw the brackets 7.1 to the front of the Hood Canopy using the screws 12a provided.
• Before tightening the Brackets completely, make all the adjustments to allow them to rest on the lower base of the Cabinet Base to avoid deformation of the upper brackets 7.2 as shown
in the gure.
9
12c
12a
7.1
12a
7.1
Fixing the Lower Brackets
5
Leveling and Securing the Lower Brackets
• With the aid of a level, set the Hood Canopy level vertically and secure it to the Lower Surface using 2 screws 12c provided.
• Tighten the screws 12a completely.
6
Securing the Squaring Brackets
• Screw the brackets 7.3 to the Hood Canopy using the screws 12b provided, without tightening completely.
• Using the screws 12c provided, fasten the other part of the brackets 7.3 either to the side walls of the unit or to the lower part of the cooktop.
Fixing the Squaring Brackets
12b
7.3
12b
7.3
12c
• Tighten the screws 12c and 12b completely.
10
7a
Internal Blower Installation
• Installation of the Internal Blower (1) at the front or rear must be decided according to the position of the cooktop, making sure that the plug is properly positioned.
• The Internal Blower can be rotated as shown in the
gure 2 for multiple venting directions..
• Screw the Internal Blower to the Hood Canopy using the screws 12a and 12b
provided as shown in the gure.
3
CAUTION - To Reduce The Risk Of Fire And Electric Shock, Install This Down Draft Only With Integral Blowers IBDD600-B Manufactured by Faber.
11
• Connect the Wire Connector from the Blower with the correct connector on the Electric Unit.
• Secure the Wire Connector from the Blower at the Electric Unit with 2 screws.
3
12
7b
Connect the Remote Blower wiring to the connector of the Electric Unit. Accessories needed:
- Remote Blower model - RB900, RB1200 (purchased separately).
- WIREBOXSCLX for Remote Blower (purchased separately).
Attention: Install the Wiring Box with two screws (provided) on a at and dry surface.
Connect the Remote Blower wiring plug connector to the connector of the Electric Unit. Run 2-wire plus ground power cable from the Remote Blower to wiring box on the Cover according to
local codes and ordinances. Use Listed ttings.
Installation of Remote Blower
CAUTION - To Reduce The Risk Of Fire And Electric Shock, Install This Down Draft Only With Remote
Blowers RB900, RB1200 Manufactured by Faber.
4x
• Connect the Wire Connector from the Blower with the correct connector on the Electric Unit.
• Secure the Wire Connector from the Blower at the Electric Unit with 2 screws.
3
13
Installation of wiring connection
Remove the wiring electrical knockout using a at-blade
screwdriver. Feed the Power Supply Cable through the electrical knockout. Connect the Power Supply Cable to the Remote Blower. Attach the White lead of the power supply (A) to the White lead of the rangehood (D) with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood (B) with a twist-on type wire connector (C). Connect the Green (E) (Green and Yellow) ground wire under the Green grounding screws.
Replace the eld wiring compartment cover
Connect the ductwork to the damper and seal all connections with duct tape. Turn the power supply on. Turn on the blower and light. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.
Hood
wiring
A
E
E
D
B
C
14
8
• Connect the wires coming out of the bottom right part of the Hood Canopy to the corresponding connector on the Electric Unit, taking care not to make any wrong connections. Check the picture below.
• Secure the Electric Unit to the Hood Canopy using the screws 12a provided.
• The Electric Unit can be installed on the left or right of the front of the hood canopy as shown above. It can also be installed on the cabinet base if space allows.
"GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualied electrician if the grounding instructions are not completely understood, or if
doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualied electrician
install an outlet near the appliance."
Warning..: Do not install the product in such a way that the electric unit is in contact with the oor.
Installation of Electrical Module
Connect the ductwork to the damper and seal all connections with duct tape. Turn the power supply on. Turn on the blower and light. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.
Power supply
Blower Connector
Command Flat Connector