1 Content............................................................................................... 6
2 Safety and general information .................................................................. 7
3 Installation requirements ......................................................................... 8
3.1 Builders opening.............................................................................. 8
3.2 Flue requirements............................................................................ 9
4 Instruction for Installation .......................................................................11
4.1 Gas connection ..............................................................................11
4.2 Preparing the appliance.................................................................... 11
4.3 Place the appliance.........................................................................11
4.4 False chimney Brest ........................................................................11
4.5 Building the False Chimney Brest with a Frameless situation........................11
4.6 Building the False Chimney Brest with a Frame........................................12
4.7 Placing the Pebbles or placing the Log/Twig set ......................................12
4.8 Placing the glass............................................................................. 12
4.9 Flue requirements...........................................................................13
5 Commissioning (functional checks) .............................................................14
5.1 Pilot ignition check .........................................................................14
5.2 Check functional burner and pilot burner...............................................14
6 Handing over (final check and customer briefing) ...........................................15
7 Servicing ............................................................................................15
7.1 Routine anual servicing .................................................................... 15
7.2 Cleaning the glass...........................................................................15
7.3 Cleaning the combustion chamber and burner.........................................16
7.4 Rebuild to other gas category (e.g. Propane/butane) ............................... 16
Appendix A: Example calculation..................................................................... 17
Appendix B: Flue restrictor............................................................................18
Appendix C: Installation of the flue..................................................................19
Appendix D: Technical specifications................................................................ 20
Appendix E: Dimensions Relaxed L with Frame ....................................................21
Appendix F: Dimensions Relaxed L Frameless...................................................... 22
Appendix G : Dimensions Ventilation grid...........................................................23
Appendix H : Dimensions Service Hatch.............................................................24
5 < < < <
UK IRL
1 Content
Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user.
This guide is concerning the following types of appliances:
RELAXED L with frame
RELAXED L frameless
Special features:
Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required)
Air supply and flue-gases go to outside atmosphere through wall or roof
Remote Control standard
Faber false chimney breast optional
Meets the requirements of the European Gas Appliance Directive (GAD) and carries
the CE mark
> > > > 6
UK IRL
2 Safety and general information
Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain any component manufactured from asbestos or any asbestos related products.
Ventilation
This appliance is room-sealed and doesn't require purpose provided ventilation. Never use the appliance if it has a broken glass.
General safety
It is the law in the UK that all gas appliances, are installed by a competent person in accordance with the Gas Safety (Installation and Use) Regulations (as amended), the relevant British Standards for Installation work, Building Regulations, Codes of Practice and the manufacturers instructions. Always use an additional guard if there are elderly, infirm or children in the same room of the appliance. The installation should also be carried out in accordance with the following where relevant:
BS5871 Part1
BS5440 Parts 1 & 2
BS1251
Building Regulations Document J (as applicable)
Building Regulations and Standards issued as relevant by the Department of the
Environment or the Scottish Development Department
In the Republic of Ireland installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions and all other regulations in force
Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty.
7 < < < <
UK IRL
3 Installation requirements
Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.
3.1 Builders opening
The Relaxed L can be build in a non-combustible fire place or builders opening. This could be either an existing builders opening or a new made prefab builders opening. When you apply your own false chimney breast design to the Relaxed L you have to meet these general requirements:
The false chimney breast has to be made of inflammable material
Always install the appliance before building up the false chimney breast
Check figure 2-3 for the dimensions
Always ventilate the space above
the appliance using vents to assure a good air-
circulation
The plaster of the outside has to be resistant to a high temperature. Therefore use the plaster materials especially made for this, to prevent discolouring (min. 100 °C temperature resistant)
Make sure the plaster dries well before using the appliance. Let the thickness in mm be the number of days the plaster has to dry
3.1.1 False chimney breast Relaxed L frameless
Use the steel building guide (fig. 2-1) mounted on the front of the appliance
Make a framework of metal studs around the steel building guide; keep in mind the
thickness of the Promatec you use!
Place metal studs at every corner of the false chimney brest; keep in mind the thickness of the Promatec you use!
Build with Promatec around the steel building guide (fig.2-2)
Build the rest of the false chimney brest
Use 12 mm Promatec for the front of the false chimney breast.
> > > > 8