1 Foreword
Dear Customer! Thank you for choosing our product! By purchasing this product you receive guarantee for
good quality originating from the usage of the finest and proven materials, operating security which is controlled according to German and European norms (Corresponds to
the standards DIN 18891 Construction Shape 1 and EN 13240.),
long life ensured by the robust structure. In order to be able to use your new fireplace for a long time please read the following instructions manual. You will find all the necessary information in it and some additional advice.
2 FETY INSTRUCTIONS
This equipment has been certified under the requirements of standard DIN EN 13240 or DIN EN
12815 (see the model plate).
For setting purposes and connection to the chimney, the fire protection requirements as
prescribed in the given locations, as well as standards DIN 4705, DIN EN 13384, DIN EN 1856-2 and DIN EN 15287 should be complied with. For the problem-free functioning of the equipment, the chimney that the fireplace is to be connected to has to be in perfect conditions (Germany).
Before the first commissioning and connection to the chimney, these user instructions are to be
read thoroughly, and the competent chimney sweeper has to be informed.
It is recommended to use clean cotton gloves for the setting of the equipment in order to avoid
the appearance of fingerprints that would be hard to eliminate later on.
In order to keep the air clean and maintain the equipment properly, the maximum fuel
quantities specified in these safety instructions may not be exceeded, and the doors of the eqipment have to be kept closed, otherwise the equipment may overheat, leading to damage. No guarantee is provided for such damage.
During operations, the doors of the equipment are to be kept always closed. Permissible fuels:
- natural wood (max. 35 cm in length)
- brown coal briquette (see user instructions)
Never use liquid igniters. Use special ignition materials or wood wool for the kindling of the
fire.
Never use wastes, fine wooden chips, mulch, coal debris, particle board wastes, wet wood or
wood treated with wood-protective agents, paper or cardboard or similar materials for burning.
Upon the first kindling, smoke and unpleasant smell may be generated. Always ensure the
proper ventilation of the room (by opening windows and doors), and heat the fireplace at maximum rated heating performance. If with the first heating the maximum temperature is not reached, the above-mentioned effects may as well arise later on.
The operating elements and adjustment units are to be used as described in these user
instructions. If the equipment is hot, use auxiliaries or protective gloves for the handling of the equipment.
When opening the furnace chamber door, any incorrect handling or insufficient draught may
induce smoke. Always ensure that the furnace chamber door may be opened only slowly, first just to a small extent, and then fully after a few seconds. In addition, if you intend to put additional fuel into the fire, before the opening of the door only there may be only ember bed in the burning space, i.e. no flames may be visible.
In heating mode, the surfaces, inspection glasses and handles may become very hot. Warn
children of these threats, and keep them away from the fireplace when heated.
Ensure that the ashtray should be fully inserted, and in particular never remove hot ash from
the fireplace (fire risk).
In transitional periods, chimney draught may drop, resulting in the imperfect suction of the
generated flue gases. In such cases, the fireplace is to be filled with smaller quantities of fuel, preferably wooden chips or wood wool, and it is to be commissioned under control with the stabilization of the chimney draught. The fire grate should always be kept clean.
After the heating season, it is recommended to have the equipment inspected by an expert. It
is also advisable to clean the routes of flue gases and pipes.
3 < < < <
Should repairs or reconditioning be needed, please, contact your dealer in a timely manner
with the accurate specification of the article and serial number. Only original Wamsler parts may be used.
As the air needed for burning is drawn from the room where the fireplace is located, ensure
that sufficient air supply is received via the gaps by the windows and external doors. Make sure that 4 m3 of air should be provided to each kW of rated performance. For this fireplace, it means that the room has to be at least 32 m in volume. If the room is smaller, sufficient air supply can be secured by opening air connections to other rooms with air openings (at least 150 cm2).
Ensure to keep proper lateral and rear distances from combustible parts and materials. The
associated values are specified in these user instructions or the model plate.
The fireplace may not be modified. The connection of the fireplace to the chimney is not permissible if the effective height of the
chimney is less than 4 m, or 5 m with multiple loading. To the chimney that the fireplace uses, a maximum of two other fireplaces, ovens may be connected.
In the event of any chimney fire, immediately close all the openings of the equipment, and
call the fire service. Never try to extinguish the fire with water. Thereafter, always have the chimney inspected by an expert.
Usage
1.1 Structure of the equipment
Data badge
Outside air intake
4 < < < <
Ash bin
Furnace chamber
door
Storage
Flue connection
5 < < < <
3 Installation
Fuels The appliance can be used with fuels detailed in the followings. This way the “low-smoke” and trouble-free operation can be secured. Use only dry wood with moisture of maximum 20%.
Types of fuels
Heating value appr.
KJ/kg
Hard wood
19.500
Soft wood
14.600
Brown-coal
11.500
3.1 Table 1
Filling quantities Split billet: max. Length: 35 cm – max. 2 billet per filling, appr. 1.7 kg Brown coal briquette: max. 1.7 kg (ca. 2 pieces).
Fuel
Setting of the
primary air
regulator
Secund air
regulator
Warning up,
kindling
II
II
Wood
Nominal heating
performance
I
II
Brown-coal
Nominal heating
performance
I
I
Putting out of working
order
I
I