Faber Ease (BF100H), SILENCE, FEELING, WHISPER, SPECTRA NOVA User Manual

...
EASE
(BF100H)
SILENCE
FEELING
SENSE
SPECTRA NOVA
CADRA NOVA
Room-sealed built-in gas-fireplace with “Flat Fibre Burner Technology” (Ease also with Pebble burner)
Installation guide and user manual
40010560
05-11
UK/IRL
2 < < < <
UK/IRL
> > > > 3
1 Index:
1 Index:...................................................................................... 3
2 Introduction .............................................................................. 5
3 Safety and general information ...................................................... 6
3.1 General safety...................................................................6
4 Installation requirements.............................................................. 8
4.1 Builders opening and surround................................................8
4.2 Fl u e requirements ............................................................ 10
4.3 Tables for determining the right flue restrictor.......................... 12
4.3.1 Terminal position....................................................... ....... ............. . 15
4.3.2 Using an existing chimney as air inlet.................................................... 18
5 Instructions for installation ..........................................................19
5.1 Gas Connection............................................ .... .... .... .... ... .19
5.2 Pr e p a ring the applian ces ................................................... 19
5.2.1 Preparing the Sense and the Ease............... Fout! Bladwijzer niet gedefinieerd.
5.2.2 Preparing the Widescreen and MV200.................................................... 19
5.2.3 Preparing the Spectra Nova and Cadra Nova............................................ 22
5.3 Pl a c ing the a ppliance ....................................................... 23
5.4 Pl a ci n g th e l o g s e t ........................................................... 24
5.4.1 Embers ........................................................................................ 24
5.4.2 Placing the log set Spectra Nova, Cadra Nova and Whisper........................... 25
5.4.3 Placing the log set Feeling, Silence, Sense and Ease................................... 25
5.4.4 Placing the pebble set Ease................................................................ 26
6 Installation of the flue ................................................................ 27
6.1 Connection with use of concentric duct material........................ 27
6.2 Connection onto an existing chimney...................................... 27
6.3 Remote control (when applicable) .........................................29
6.3.1 Installation.................................................................................... 29
7 Commissioning (functional checks).................................................31
7.1 Check pilot ignition........................................................... 31
7.2 Functional burner check .....................................................31
7.3 Functional balanced flue check............................................. 32
7.4 Check setting pressure ............................................... .... ... .32
8 Handing over (final check and customer briefing ...............................33
9 Servicing ................................................................................. 34
9.1 Routine anual servicing ...................................................... 34
9.1.1 Cleaning the glass ........................................................................... 34
9.1.2 Cleaning the combustion chamber and burner.......................................... 35
9.1.3 Burner tray assembly........................................................................ 35
9.1.4 Pilot/thermocouple assembly.............................................................. 36
9.1.5 Gas control block................. ...... ............. ....... ...... ............. ...... ....... . 36
9.1.6 Combustion test.............................................................................. 36
9.2 Propane conversion........................................................... 37
9.3 List of spare parts............................................................. 37
9.4 Technical Specifications ..................................................... 38
User Manual ................................................................. 39
10 Safety instructions for the user ..................................................... 40
11 Controlling the appliance.............................................................42
11.1 Lighting the fire...............................................................42
11.2 To light .........................................................................43
11.3 To extingish....................................................................43
11.4 Remote Control (when applicable).........................................44
11.4.1 To light....................................................... ................................. 44
UK/IRL
4 < < < <
11.4.2 To extinguish......................................... ...... ....... ............. ...... ...... ... 45
11.4.3 Setting the right transmission code .......................................................45
11.4.4 Changing batteries ......... ...... ............. ...... ....... ............ ....... ...... ......... 46
12 Cleaning and service instructions .................................................. 47
13 Disposal of packaging and appliance ............................................... 48
UK/IRL
> > > > 5
2 Introduction
Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user.
This guide is concerning the following types of appliances:
Widescreen interior: Types Silence and Feeling
MV100/MV200 interior: Type Spectra Nova and Whisper
MV150 interior: Type Cadra Nova
Special features:
Realistic flame and glow effect because of the "Flat Fibre Burner" technology.
Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required). No additional ventilation required.
Air supply and flue-gases go to outside atmosphere through wall or roof. A maximum horizontal extension of 6 meters is possible.
Remote Control option on all appliances.
Meets the essential requirements of the European Gas Appliance
Directive (GAD) and carries the CE mark.
UK/IRL
6 < < < <
3 Safety and general information
Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.
This gas appliance is factory set and shall not be adjusted by the installer.
This appliance does not contain any component manufactured from asbestos or any asbestos related products.
The pilot and flame sensing device fitted to this fire is also a safety device. If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner, thermocouple, electrode and injector must be exchanged complete for a pilot assembly from the original manufacturer only.
Ventilation
This appliance is room-sealed and doesn't require purpose provided ventilation.
3.1 General safety
It is the law in the UK that all gas appliances, are installed by a competent person in accordance with the Gas Safety (Installation and Use) Regulations (as amended), the relevant Britis h Standards for Installation work, Building Regulations, Codes of Practice and the manufacturers instructions.
The installation should also be carried out in accordance with the following where relevant:
BS5871 Part1
BS5440 Parts 1 & 2
BS1251.
Building Regulations Document J (as applicable).
Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department.
UK/IRL
> > > > 7
In the Republic of Ireland installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions and any other rules in force.
Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty.
Safety instructions for the user: see chap ter 10.
UK/IRL
8 < < < <
4 Installation requirements
Note:
Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot.
As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.
4.1 Builders opening and surround
The appliance can be installed in the following situations: In a non-combustible fireplace or builders opening. This coul d be ei ther
an existing builders opening or a new made prefab builders opening. For the measurements, see figure 1 and index.
Although the appliance is tested for installation without a hearth, the appliance must not stand on combustible materials or carpets. If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it. Any under floor vents or openings within the builders opening should be sealed off.
Do not place the lintel, surround or marble stone directly onto the appliance. If possible, apply a lintel made of cement or something similar.
Insulate the appliance with a ceramic blanket (25 mm). See also chapter 4: Installation instructions. Preferred choice for insulation is unbound insulation wool (at 1000 °C gives no smell).
UK/IRL
> > > > 9
Builders opening (mm) Feeling Sense
Silence Eas
e
(BF100H)
Whisper Spectra
Nova
Cadra
Nova
Misty
Builders opening (mm)
A Open ing width
960 960 960 920 780 780 680 710
B Opening height
649 649 649 590 705 698 798 890
C Opening depth (min.)
385 385 385 397 430 430 430 370
Shelf dimensions D Minimum height shelf
from top frame
350 350 350 350 350 350 350 350
E Depth shelf
150 150 150 150 150 150 150 150
Dimensions of the appliance (mm)
F Box width
885 885 885 885 750 750 650 698
G Box depth
369 366 369 366 397 375 375 338
H Box height
605 605 605 605 714 715 815 879
I Frame width
1064 1 136 1064 985 815 794 694 740
J Frame height
678 750 678 599 720 703 803 905
K Frame thickness
47 57 20 36 16 30 30 144
L Position flue collar
measured from frame
255 255 255 255 257 235 235 196
M Position flue collar
measured from back
111 111 111 111 140 140 140 142
N Height underside foot to
underside frame
17 -20 17 50 8 0 0 ?
O Height underside foot to
builders opening
N (=dimensions in the row above)
table 1
*point A to C have a tolerance of -0 mm and +5 mm.
UK/IRL
10 < < < <
If the builders' opening is constructed out of non-combustible composition board (Fibrelux) and you install the appliance without a mantel then:
Ventilate the space above the appliance (min. 1000 mm2 ).
Always fit the DC convection set.
The plaster of the ou tside has to be resis tant to a high temperature.
Use therefore the plaster materials especially made for this, to prevent discolo u r in g (mi n. 100 °C temperature resistant).
The plaster has to dry for at least 1 day per millimetre plaster. This means that 4 mm plaster has to dry for at least 4 days before the appliance should be used. This is to avoid cracking.
If the appliance is to be fitted against a wall with combustible cladding, the cladding must be removed from the area covered by the surround.
The minimum height from the top surface of the fire to the underside of any shelf made from wood or other combustible materials is as follows:
For a shelf up to 150 mm deep – Minimum height = 350 mm (fig. 1).
If the shelf depth is greater than 150 mm add 50 mm to the upper
clearance height for every 25 mm increase in shelf depth.
Side clearance = Minimum distance from the side of the fire frame to combustible material = 150 mm.
4.2 Flue requirements
The appliance is of the type C11/C31. The appliance will need to be
supplied with the approved flue pipes and terminal, it is not possible to supply your own.
The minimum effective height of the flue system must be 0.5 or 1
meter, depending on the appliance.
Terminal locations, through the wall as well as through the roof. See
figure 3.
Flue routing;
a horizontal extension with elbows is allowed for a maximum of 6
meters (depending on the type and situation).
UK/IRL
> > > > 11
vertical max. 12 meters.
Determine on the base of the table 2 and 3, depending on the type and terminal position, if the desired situation is possible. To establish this you will need to calculate:
The effective height (this is the real difference in height between the
upper side of the appliance and the terminal).
The total horizontal extension. This is the total horizontal flue length
where:
à each elbow, which is in the horizontal area, counts for 2 meters. à each 45-degree bend, which is in the horizontal area, counts for 1
meter.
à elbows and bends at the transition of horizontal to vertically are
not to be counted.
à the wall mounted terminal counts for 1 meter.
Flue restrictor
If applicable, in the table is also stated the size of a flue restrictor. This restrictor needs to be fitted in the combustion chamber when placing the appliance (see chapter 4.2). Normally the smallest flue restrictor is fitted.
Example calculation 1:
Calculating horizontal extension fig. 2a:
Flue lenght C + E = 1m + 1m 2 m Elbows D = 2m 2 m Total horizontal extension 4 m
Measure or calculate effective height (Hvert)
Flue lenght A 1 m Roof mounted terinal 1 m Total effective height 2 m
UK/IRL
12 < < < <
When calculating on basis of the Widescreen table nr. 2: It is allowed. Remove the flue restrictor!
When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of theMV150 table nr. 4: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the Roundscreen table nr. 5: Allowed but without flue restrictor. Remove the flue restrictor!
Example calculation 2
Calculation horizontal extension fig. 2b:
Flue lenght J + L = 0,5 + 0,5 1 m Elbows K + M = 2m + 2m 4 m Terminal 1 m Total horizontal extension 6 m
Calculation effective height (Hvert)
Flue lenght H 1 m When calculating on basis of the
Widescreen table nr. 2: Combination not allowed.
When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the MV150 table nr. 4: Combination not allowed.
4.3 Tables for determining the right flue restrictor
Calculate the total horizontal- and vertical length of the flue, according to the calculations displayed above. Determine according to tables 2, 3, 4 and 5 on the following pages the right flue restrictor size. When meeting
UK/IRL
> > > > 13
an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.
UK/IRL
14 < < < <
0123456
0xxxxxxx 1
00
xxxxx
1,5 000xxxx
2 30 30 0 0 xxx 3 45 45 30 0 0 0 x 4
45 45 30 30 30 0 0
5
50 50 45 30 30 30 0
6 50 50 45 30 30 30 0 7 60 60 50 45 45 30 x 8 60 60 60 50 50 xx 9
65 65 60 60
xxx 10 65 65 65 xxxx 11 65 65 xxxxx 12 65 xxxxxx
0123456
0XXXXXXX 130000000/X* 2303000000 3 4545300 0 0 0 4 4545300 0 0 0 5 5050454530 0 0 6 5050454530 0 0 7 606060505045 X 8 6060606050 X X
9 65656060 X X X 10 65 65 65 X X X X 11 65 65 X X X X X 1265XXXXXX
Table 2: Widescreen (Ease (BF100H), Feeling, Silence, Sense)
Vertical length in m
Table 3: MV100/MV200 (Spectra Nova, Whisper)
Horizontal length in m
Vertical length in m
The numbers in the table represent the width in mm of the flue restrictor
X Combination NOT allowed
0 remove flue restrictor
The numbers in the table represent the width in mm of the flue restrictor
X Combination NOT allowed
0 remove flue restrictor
Horizontal length
in m
Met opma
a
pt, Cursief, (Groot-Britt
a
Met opma
a
Engels (Gro
Met opma
a
Engels (Gro
Met opma
a
pt, Cursief, (Groot-Britt
a
Met opma
a
Engels (Gro
Met opma
a
Engels (Gro
UK/IRL
> > > > 15
0123456
0XXXXXXX
0,5X0XXXXX
1X3000000 2403000000 3 404030 0 0 0 0 4 50404030 0 0 0 5 505040403030 0 6 505050404030 0 7 605050404040 X 8 6060505050 X X
9 60606050 X X X 10 65 60 60 X X X X 11 65 65 X X X X X 1265XXXXXX
4.3.1 Terminal position
Verify if the required terminal position meets the local installation regulations regarding disturbance, good functioning and ventilation. (Also see: safety requirements).
Note:
The terminal must be located so that the outlet is not obstructed. If the flue terminal is located within 2 meters of a footway, path or where people could come into contact with it, then a suitable terminal guard must be fitted.
Terminals located close to shared walkways, footpaths etc. could be subject to legal constraints and this should be pointed out to the customer before installation. If in any doubt about flue location advice should be sought from local building control, or if appliance-related, from the manufacturer including wherever possible a dimensioned sketch.
Avoid locating the terminal in close proximity to plastic materials such as gutters or other combustibles. If this is unavoidable then a suitable deflector should be made.
Tabel 4: binnenwerk MV150 (Cadra Nova)
Vertical length in m
Horizontal length in m
The numbers in the table represent the width in mm of the flue restrictor
X Combination NOT allowed
0 remove flue restrictor
Met opma
a
pt, Cursief
Met opma
a
Engels (Gro
o
UK/IRL
16 < < < <
Some important requirements for a good functioning are: The wall-mounted terminal has to be at least 0,5 m off:
à Corners of the building. à Below eaves. à Balcony's etc. unless the duct is dragged to the front side of the
overhanging part.
The roof mounted terminal has to be at a distance of at least 0.5 meters of the sides of the roof, excluded the ridge.
UK/IRL
> > > > 17
Dimension Terminal position
(kW input 7.5 kW expressed in net)
Balanced flue
room sealed
Natural Draught
A Direct below an opening, airbrick, opening
windows, etc.
300 mm
B Above an opening, airbrick, opening window , etc. 300 mm C Horizontally to an opening, airbrick, opening
window, etc.
300 mm
D Below gutters, soil pipes or drain pipes 500 mm E Below eaves 500 mm F Below balconies or cat port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H Dfrom an internal or external corner 600 mm
I Above ground roof or balcony level 300 mm
J From a surface facing the terminal 600 mm K From a terminal facing a terminal 600 mm L From an opening in the carport (e.g. window) into
the dwelling
1200 mm
M Vertically from a terminal on the same wall 1500 mm N Horizontally from a terminal on the same wall 300 mm
P From a vertical structure on the roof 600 mm
Q Above intersection with roof 500 mm
Flue terminal
Fig. 3
Table 5
Met opma
a
pt, Cursief
UK/IRL
18 < < < <
4.3.2 Using an existing chimney as air inlet
You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function.
Requirements:
Any existing chimney used as an air supply must only service this appliance.
A chimney that has previously been used for solid fuel must be swept before use.
The existing chimney needs to be airtight.
The existing chimney needs to have an opening of min. 150 x 150 mm.
The chimney needs to be intact and well looked after.
Use the adjustable roof-mounted-terminal especially made for this,
and the chimney connection set.
The min. distance between two terminals should be at least 450 mm.
Example of how terminal position is measured
Fig. 4
UK/IRL
> > > > 19
5 Instructions for installation
5.1 Gas Connection
1) Installation pipes should be in accordance with BS 6891. Pipe work
from the meter to the appliance must be of adequate size.
2) The complete installation including the meter must be tested for
soundness and purged as described in the above code.
3) A means of isolation must be provide in the supply to facilitate
servicing.
4) The connection should be made in 8 mm copper or similar semi
flexible tube. (max 1 meter). Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls.
5) The gas connection is nut and olive suitable for 8 mm pipe.
5.2 Preparing the appliances
Before you can install the appliance properly, it is wise to prepare the appliance, because you still have access to all parts of the appliance. These will be barely reachable once the appliance is in stalled. In the next paragraphs these preparations will be described for the different models.
5.2.3 Preparing all Widescreen models and MV200
1) Open the ashtray door by pushing on the right side for the
Silence/Feeling and on the left side for the Whisper. Remove the
UK/IRL
20 < < < <
frame by loosening the screws A behind the door (see fig. 6). Lift and pull forward and take it away.
2) For the Sense and the Ease: Pull the underside of the (inner) frame
towards you. Push the blocking strips up. Lift the (inner) frame and remove it.
3) Remove the back panel by loosening the screws B (see fig. 7).
4) Remove the glass by removing the glass clamps C (see fig. 8) for
instance with a screwdriver. Careful when removing the glass! Wear gloves! Before placing the glass back, be sure that there are no
Fig. 7
Fig. 6
UK/IRL
> > > > 21
fingerprints on the glass, it is not possible to remove them when they
are burnt in.
5) Take the box with the log set out of the combustion chamber.
6) Place the right flue restrictor in the combustion chamber. To
determine the right flue restrictor, see paragraph 4.2 and 4.3.
Attention: y If possible, first install the appliance before building up the false
chimney breast.
Fig. 9
Fig. 8
UK/IRL
22 < < < <
y If possible, install the appliance, before installing the flue. If this is
not possible, a slidable piece of pipe should be used as a connection.
5.2.4 Preparing the Spectra Nova and Cadra Nova
1) To open the door, remove the screws A (see fig. 10). Open and
remove the door; lift and pull forward. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints once they are burned in the glass.
2) Remove the outer frame by removing screws B (see fig. 11) and taking
away the frame.
3) Take the box with the log set out of the combustion chamber.
4) Like in the previous models, place the right flue restrictor in the
combustion chamber (see fig. 9). To determin e the right flue restrictor, see paragraph 4.2 and 4.3.
A
A
Fig.10
Fig.11
UK/IRL
> > > > 23
Attention:
If possible, first install the appliance before building up the false chimney breast.
If possible, install the appliance, before installing the flue. If this is not possible, a slidable piece of pipe should be used as connection.
5.3 Placing the appliance
Points of attention for placement:
If possible, first place the appliance before assembling the flue.
If this is not possible then always use an extendible pipe before
connection onto the appliance.
1) Position the firebox in the fireplace opening. You can adjust the
height with the 4 adjustable feet.
2) Make the gas connection according to the in structions (also see gas
connection, chapter 5.1).
3) Assemble the flue system onto the firebox (see chapter 5).
4) Check, when applicable, if the safety hatch seals the combustion
chamber properly. Do not fasten it at all! If you fasten it, the explosion safety hatch won’t function properly!
5) If necessary, place the DC convection system (also consult the
instruction belonging to the DC construction set).
Fig.13: Safety hatch
UK/IRL
24 < < < <
6) If necessary, isolate the firebox with a ceramic blanket (25 mm).
Preferred choice for insulation is unbound insulation wool (at 1000 °C gives no smell).
7) Place the log set (see placing log set, chapter 5.4).
8) Spread, the bags of embers (imitation ashes) provide with the
appliance over the burner tray. Attention! No embers on the grid end between the logs and the burner tray!
9) Before placing the glass; check the glass sealing rope is in good
condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints once they are burned in the glass:
Widescreen and Whisper; Place the glass in front of the appliance and fix it with the glass clamps. Replace the frame.
Cadra Nova and Spectra Nova: Place the door and fix it. Check on visual leakages around the door sealing.
10) Widescreen: Fix the outer frame with 4 screws.
After installation, let the appliance burn for max. an hour. Afterwards, check the glass for possible dirt , dust and other deposit and remove it.
5.4 Placing the log set
Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International BV. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.
5.4.1 Embers
There are 4 different types of imitations ashes provided with the appliance.
Type 1: To spread over the burner to achieve the glowing affect Type 2: Yellow bark Type 3: Anthracite bark Type 4: Vermiculite corn
UK/IRL
> > > > 25
Type 2, 3 and 4 are only for decoration purpose, don't put them on the burner.
5.4.2 Placing the log set Spectra Nova, Cadra Nova and
Whisper
The log set consists of a rear log, which is permanently a ttached to the combustion chamber, and four logs. The logs must rest on the log holder and the rear log.
Ensure that the pilot burner remains visible after installation of the log set. When not placing the log set correctly, the flames tend to burn to the front agai nst the window.
5.4.3 Placing the log set Feeling, Silence, Sense and Ease
The log set consists of two rear logs and six ceramic logs.
Put the two rear logs on the tray at the back of the combustion chamber.
Fig. 16
Fig 15
UK/IRL
26 < < < <
Put the others exact as showed on the picture. On the front the logs must lay at the holes, on the back they rest on the rear logs.
5.4.4 Placing the pebble set Ease
Spread the pebbles over the bottom of the combustion chamber. Make sure that the pilot is not covered or blocked by the pebbles. See fig 17 for more details.
Fig. 17
UK/IRL
> > > > 27
6 Installation of the flue
6.1 Connection with use of concentric duct material
1) Build the system starting from the appliance on.
2) Make a hole of ø 153 mm for the wall or roof mounted terminal.
3) Make sure you place the pipes in the right direction, the narrow end
towards the appliance.
4) Make sure the pipes are fixed sufficiently, a wall clamp every 2m, so
the weight of the pi pes is no t resting onto the appliance.
5) The outside of the pipe can become hot (140 degrees). Stay 50 mm
away from wall surface or sealing. Make sure to provide sufficiently heat resistant isolation when going through the wall or roof.
6) Because of expansion or cooling down the concentric pipes can turn
loose. It is recommended to fix the spring clip with a self tapping screw at inaccessible places.
7) To get the exact measure flue length you can use cut down concentric
pipe, wall mounted terminal or roof mounted terminal. To obtain a smoke sealed connection, the inner pipe must be 20 mm longer then the outside pipe.
8) The horizontal pipes need to rise away from the appliance at a rate of
3 degrees per metre.
6.2 Connection onto an existing chimney
You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function. Any existing chimney used as an air supply must only service this appliance.
Requirements:
300 mm of free space above the appliance;
The chimney only supply’s air to this appliance;
UK/IRL
28 < < < <
The existing chimney needs to be clean and very well swept;
The existing chimney needs to be airtight;
The existing chimney needs to have an opening of min. 150 x 150 mm.
Parts needed for this kind of installation:
Chimney connection set part number A9225000 Fig 20 part D.
Short roof terminal part number A9266100 Fig 19 part B
Chimney closure plate part number A 9240000 Fig 19 part A
Two stainless steel tubes one 100 mm ­length 500 mm and one 150 mm - length 500 mm part number A 9273900 Fig 19 part E and F
Installation:
1) Place the aluminium closure plate (A)
onto the chimney. Permanently attach and make airtight.
2) Pull the liner (C) through the chimney.
3) Connect the liner onto the roof terminal
and fix this with the clamp provided with the chimney connection set.
4) Place the roof terminal onto the closure
plate.
5) Fixing the chimney sealing plate (D) and
place the 150 mm grommet into the hole of the sealing plate.
6) Fix the sealing plate air tight into the builders opening (use isolation
rope from the chimney connection set to make the plate air tight).
7) Slide pipe (E) 150mm length 500mm into the sealing plate. Slide this
pipe so that you have enough space later on to assemble the liner.
Fig. 18
UK/IRL
> > > > 29
8) Install the appliance.
9) Connect the flexible stainless steel liner onto the appliance using the
100mm pipe (F) as adapter.
10) If the distance from the flue outlet to the sealing plate is bigger then
300 mm, you have to use a concentric pipe first.
11) Slide the outside pipe onto the appliance or concentric extension so
that you have a air tight connection.
6.3 Remote control (when applicable)
The remote control is only meant to regulate the flames, it functions only when the pilot burner is ignited. It is therefore not possible to ignited the appliance with the remote control or to shut-off the pilotflame.
The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland and Greece.
Features:
- Manual control will always remain possible.
- The remote control is a radio frequency type and has been approved internationally.
- The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car.
- The remote control is easy to install retrospectively.
6.3.1 Installation
1) Connec t th e transform e r to the receiver box. The adapter is set to the
correct voltage in the factory 4.5 V.
Fig 19
UK/IRL
30 < < < <
2) Slide the receiver box into the holder.
3) Connect the wires to the gas control (see fig.20 ).
4) Check ifthere are batteries in the transmitter. See "Replacing batteries", see chapter 10.4.4.
5) Set the on/off switch on the receiver to "on".
Setting the right transmission code
The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period.
1) Push the "mod" button on the receiver and hold it for 3 seconds.
2) The green control lamp will light up and stay on. Repeat this step if it doesn't.
3) Push a button on the remote control. The control lamp on the receiver should now go out.
4) Again push a button on the remote control. The lamp starts flashing and will switch off eventually.
5) The receiver now recognizes the remote control. The remote control now functions.
6) Check if you can hear a sound and the motor runs when you push a button on the remote control.
Fig. 20
UK/IRL
> > > > 31
7 Commissioning (functional checks)
7.1 Check pilot ignition
1) Push in and turn the control knob (a) from anti-clockwise to the
setting
(small flame). You will hear a tick, meaning there is ignition.
Hold the knob in and wait for a few seconds while the air is purged;
2) Bring the knob back in start position and turn the knob several times
to the
position . Check if the pilot has lit;
3) Continue to hold in the control knob for a further 10 seconds to
ensure that the pilot flame is stable;
4) Release the knob. The pilot should remain alight. If not, repeat the
previous steps.
7.2 Functional burner check
1) Turn knob (B) to max. clockwise;
2) Turn knob (A) more anticlockwise to the position (large flame). Now
it’s possible to light the main burner;
3) Turn knob B anticlockwise to its max. The main burner should light.
Check for gas soundness at all joints with leak detection fluid.
4) Check the ignition of the main burner on low and high setting;
5) Turn knob B clockwise till . The main burner is off;
6) Turn knob A to . The pilot should go out.
Fig. 21
UK/IRL
32 < < < <
7.3 Functional balanced flue check
1) Set the appliance on max. input;
2) Verify the flame picture, this means no flames against the window,
the flame have to come besides the logs, if not check the log layout.
3) Check if the flames are yellow after 10 minutes of operation. If you
still have a blue flame or the appliance goes out check: a) If the flue pipes are fitted correctly (no leakage).
b) If the wall mounted terminal is placed with the correct side up. c) If the correct flue restrictor is installed.
7.4 Check setting pressure
The appliance is preset to give the correct heat input. No further adjustment is necessary. Fit a pressure gauge at the test point D to check the burner pressure.
The pressure should be checked with the appliance alight and at max input. The setting pressure should be as shown in paragraph 9.4 .
After checking the pressure, turn off the appliance. Remove the pressure gauge and close the sealing screw. Re-light the appliance. Turn to max. input and test around the test point D for gas soundness using a suitable leak detection fluid.
Fig. 22
D C
B A
UK/IRL
> > > > 33
8 Handing over (final check and customer briefing
- Instruct the customer on the full operation of the appliance.
- Advise the customer how to clean the appliance including the glass.
- Instruct the customer on the operation of the remote control, including replacement of batteries and how to set the right transmissions code.
- Hand over these instructions including the user guide to the consumer.
- Recommend that the appliance should be serviced by a competent
person at least once a year.
UK/IRL
34 < < < <
9 Servicing
To ensure safe, efficient operation of the appliance, it is necessary to carry out routine servicing at regular intervals.
It is recommended, that the fire is inspected/serviced by a competent person at least once a year.
Important Turn off the gas supply before commencing any servicing. Always test
for gas soundness after refitting the appliance!
9.1 Routine anual servicing
1) Clean (if necessary): a. the pilot system; b. the burner; c. the combustion chamber; d. the glass.
2) Check the log lay and replace the embers (if applicable).
3) Do the functional test as described at page 32.
4) Check the flue system and terminal on damage an d soundness (visual
inspection).
9.1.1 Cleaning the glass
Depending on the intensity of use, you can get a deposit on the glass. This can be removed with a special ceramic glass cleaner (ceramic cook-top cleaner) as follows:
1) Remove the f ro n t and th e back .
2) Clean the glass. Handle the glass with clean hands, wear gloves if
possible.
3) To fit the glass, proceed in reverse order. Make sure that the log set
has been installed correctly before fixing the glass.
Attention:
Before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the
UK/IRL
> > > > 35
glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass in front of the appliance and fix the glass frame or use the glass clamps.
9.1.2 Cleaning the combustion chamber and burner
If the burner is visibly damaged, this can affect the distribution of the flame, if so then replace the burner.
9.1.3 Burner tray assembly
1) Remove the front, glass, and log holder (if applicable)
2) Break the gas supply at the control valve.
3) Unscrew the burner assembly and take th em out of the combustion
4) chamber. Attention! A sharp or heavy object can damage the burner.
A. Pilot assembly B. Burner C. Fixation plate D. Injector E. Gas control
F. Receiver
Fig. 23
UK/IRL
36 < < < <
9.1.4 Pilot/thermocouple assembly
This is not a serviceable item, both thermocouple and pilot should be replaced together.
Pilot/thermocouple assembly
1) Remove the burner tray.
2) Remove the lead from the pilot spark igniter.
3) Break the gas pipe connection to the pilot.
4) Unscrew thermocouple nut from the rear of the gas control.
5) Unscrew pilot assembly from the burner tray (2 screws)
6) Replace and re-assemble in reverse order.
9.1.5 Gas control block
A Govenor; B Adjustable screw pilot flame; C Inlet pressure test point ;
D Burner pressure test point.
9.1.6 Combustion test
A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet.
Fig. 25
D C
B A
Fig. 24
UK/IRL
> > > > 37
A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. (100 ppm CO per 1% CO2).
A reading of CO in the room centre should give a rise of less than 9ppm over ambient, peak reading.
9.2 Propane conversion
For conversion from propane to natural gas (or the other way around), you have to order a complete new propane burner unit. Contact your supplier and give the serial number from the data plate when you order.
9.3 List of spare parts
Whisper Feeling Sense Silence Ease
(Bf100 H)
FFB
Ease
(Bf100 H)
PB
Spectra
Nova
Cadra
Nova
Omschrijving
Number Number Number Number Number Number Number Number
Surround Antracite
A9271453 A9270053 X A9267753 20847648 20847648 A9274149 A9274149
Surround St. Steel
X X X X 20848003 20848003 X X
Surround Bronze:
X X X X X X X X
- inner frame
X X 20837393 X X X X X
- outer frame
X X 20837493 X X X X X
Glass
04508200 04508300 04508300 04508300 04508300 04508300 0450950 04509300
Glass operation
X X X X X X 09509600 04509400
Burner NG
20521405 20525905 20525705 20525905 20900240 20900241 20521405 20522605
Log set
20773200 20794500 20794500 20794500 20794500 X 20773200 20794500
Pebble set
X X X X X 20799100 X X
Spark wire
06017300 06017300 06017300 06017300 06017200 06017200 06017300 06017300
Receiver
20604000 20604000 20604000 20604000 20604000 20604000 20604000 20604000
Remote control
20603900 20603900 20603900 20603900 20603900 20603900 20603900 20603900
Adapter
20900142 20900142 20900142 20900142 20900142 20900142 20900142 20900142
Gas control
37003089 37003089 37003089 37003089 37003089 X 37003089 37003089
Motor Remote control
37003086 37003086 37003086 37003086 37003086 37003086 37003086 37003086
Oxypilot
37001042 37001042 37001042 37001042 37001042 37001042 37001042 37001042
Thermocouple
37002033 37002033 37002033 37002033 37002033 37002033 37002033 37002033
Bougie
06006600 06006600 06006600 06006600 06006600 06006600 06006600 06006600
Embers
20793400 20793400 20793400 20793400 20793400 20793400 20793400 20793400
Lack spray for combustio n chamber
09000008 09000008 09000008 09000008 09000008 09000008 09000008 09000008
Lack spray for front
X X X X 09000014 09000014 X X
Glass clamps
20900008 20900008 20900008 20900008 X X X X
Touch Latch assembly
28103900 28103900 X 28103900 X X X X
Table 6: List of spare parts
UK/IRL
38 < < < <
9.4 Technical Specifications
Widescreen
(incl. Ease)
Flat Fibre
Ease
Pebble burner
MV100 / MV200
Whisper /
Spectra Nova
MV150
No
v
Country UK/IRL UK/IRL UK/IRL UK/
I
Category I2H I2H I2H I2
H
Type C11 of C31 C11 of C31 C11 of C31 C11 o
f
Type of gas G20 G20 G20 G
2
Heat input Hi [kW] 6.1
7.1
7,2 6.
1
Efficiency class 2
2
2 2
NOX class 4
-
4 4
Working pressure [mbar] 20
20
20 2
0
Gas rate At 15º C and 1013 mbar [l/h] 800
750
640 63 gram/h 540 gram Setting pressure [mbar] 13
10
10 10
.
Injector size [mm] 2.4
2.55
2.2 2.
2
Reduced input restrictor [mm] 1.8
1.8
1.6 1.
6
Pilot Assembly
Type Oxy-pilot
OP9709
Oxy-pilot Oxy-
p
Code 9709M NG
9709M NG 9709
M
Flue system
Ø MVr mm 100-150
100-150
100-150 100-
Preinstalled flue restrictor mm 30
30
30 3
0
Gas control Maxitrol GV 36
GV3636-
C5AOEHC68M
GV3636-
C5AOEHC68M
GV3636-
C5AOEHC68M
GV3
6
C5AOE
H
Remote control
Voltage adapter V 4.5 4.5 4.5 4.
5
Batteries remote control V 2x 1,5V Alkaline 2x 1,5V Alkaline 2x 1,5V Alkaline 2x 1,5V
A
Gasaansluiting
8 mm nut and
olive
8 mm nut and
olive
8 mm nut and
olive
8 mm n
oli
v
Afmetingen zie tabel1
Table 7: Technical specifications of the Widescreen, MV100/MV200 and the MV150
UK/IRL
> > > > 39
User Manual
UK/IRL
40 < < < <
10 Safety instructions for the user
If a gas leak is found or suspected, turn off the gas supply at the meter and contact your installer or gas emergency service.
These instructions should be read carefully and retained for future reference.
Do not use the fire with a broken or damaged glass.
The fire has a safety device which turns off the gas supply if there is a build up from flue gasses in the combustion room or a temporary gas cut­off. Wait at least 5 minutes before turning the appliance on again. Contact a qualified installer when the appliance goes off regularly.
The appliance has been designed for heating purposes. This means that all surfaces, including the glass, can become very warm (over 100 °C). An exception to this is the lower side of the door and the control buttons.
Due to the newness of materials, they may give off a slight smell for a period after initial lighting. This is normal, odours will disperse after a few hours use.
Do not place curtains, clothing, laundry, furniture or other flammable materials nearby the appliance. The required minimum distance is 100 cm.
Switch off the receiver of the remote control if you don’t use the fire for a long time. Do not let children use the remote control without supervision.
IMPORTANT
A suitable Fireguard conforming to BS6539 and BS6778 should be used with this appliance to protect children, the elderly or infirm. Care should also be taken with pets.
In your own interest and that of safety, all gas appliances must be installed by competent persons. Installation must be in accordance with National Regulations. CORGI registered installers are required to work to recognised standards.
UK/IRL
> > > > 41
Note: Since the appliance is a source of heat, circulation of air occurs.
Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.
UK/IRL
42 < < < <
11 Controlling the appliance
11.1 Lighting the fire
If the main burner or pilot light are extinguished for any reason, do not attempt to relight the pilot within 5 minutes. Contact a qualified
installer when the appliance goes off regularly. The control valve is behind the ashtray door.
Silence /Feeling /Whisper
Open the ashtray door by pushing on the right side for the Silence/Feeling and on the left side for the Whisper.
Sense (remote control only) Access to the controls by pulling the inner frame forwards.
Cadra Nova and Spectra Nova
Open by pushing the lip located on the right side in the gap between the
ashtray door and the frame (door flaps open). With control button A you can light the pilot. With the control button B
you can adjust the height of the flames (see fig. 26).
Knob A
The
is the OFF position preventing any gas from passing through the
control valve to either the pilot burner or to the main burner. By pressing the knob in it is possible to turn it anticlockwise. The first function is to turn on the gas to the pilot- this occurs just before reaching the
Fig. 26
UK/IRL
> > > > 43
position (if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner). Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click at the valve and should result in the pilot burner igniting. Once the pilot is lit, the control
knob should be held pressed in for 10 seconds. In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold-on magnet within the valve. Now turn the control knob A to the
position. This allows gas to enter control knob B.
Knob B
The
is the OFF position preventing gas entering the main burner if the pilot is lit. The knob should be turned slowly anticlockwise. This allows gas to enter the burner and be ignited by the pilot flame. Once ignition has taken place, the fire may be set to any level between min. and max. by adjusting the control knob B.
11.2 To light
1) Push in and turn the control knob (A) from anticlockwise to the
setting
(small flame). You will hear a ignition click. Check that the
pilot is lit (if not repeat).
2) Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
3) Release the knob. The pilot should remain alight.
4) Turn the control knob A to the
position.
5) Turn knob B slowly anticlockwise, the fire should then ignite.
6) Adjust flames to the required level.
11.3 To extingish
1) For the main burner turn the control knob B clockwise to position .
2) To disable knob B turn knob A to the position
.
UK/IRL
44 < < < <
3) To extinguish the pilot turn control knob A to position , although it is in order lo leave the pilot permanently lit.
When the pilot extinguishes
Warning! When the pilot extinguishes, for whatever reason, you should
wait at least 5 minutes before trying to turn it on again. Possible causes of pilot extinguish are:
- Operating error.
- Interference of the safety device.
- Failure in the pilot flame system.
Contact a qualified installer when the appliance goes off regularly.
11.4 Remote Control (when applicable)
The remote control is only meant to regulate the flames from off till max. It functions only when the pilot burner is ignited and knob A is in
(big flame) position. It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame. The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland, and Greece.
Features:
- Manual control will always remain possible.
- The remote control is a radio frequency type and had been
approved internationally.
- The remote control generates a unique safety code every
time you activate the transmitter, its similar to those used in a car.
- The remote control is easy to install retrospectively.
11.4.1 To light
1) Push in and turn the control kn ob (A) from { anticlockwise to the
setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).
Fig. 27
UK/IRL
> > > > 45
2) Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.
3) Release the knob. The pilot should remain alight.
4) Turn the control knob A to the position.
5) Set the on/off switch on the receiver to "on”.
- low flame
- high flame
6) Use the
and buttons to achieve the desired heating and flame
effect.
7) You will hear a beep every time the receiver recognises a good signal. (If not, so see 10.4.3, setting the right transmission code).
8) When the fire is not be used for a prolonged period, turn off the pilot
(see 10.4.2)
11.4.2 To extinguish
1) Push
(low) till the burner goes out and you c an hear the motor
clicking.
2) To enable the remote control turn knob A to the
position.
3) To extinguish the pilot turn control knob A to position
, although it is
in order to leave the pilot permanently lit.
11.4.3 Setting the right transmission code
The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period.
1) Set the on/off switch on the receiver to "on".
2) Push the "mod" button on the receiver and hold it for 3 seconds.
3) The green control lamp will light up and stay on. Repeat this step if it
doesn't.
UK/IRL
46 < < < <
4) Push a button on the remote control. The control lamp on the receiver should now go out.
5) Again push a button on the remote control. The lamp starts flashing and will switch off eventually.
6) The receiver now recognizes the remote control. The remote control now functions.
7) Check if you can hear a sound and the motor runs when you push a button on the remote control.
11.4.4 Changing batteries
There is no risk of electric shock as the low voltage supply is similar to that used in torches. Always turn off the appliance before changing batteries.
Remote control
1) Remove the cover on the back of the remote control.
2) Carefully remove the battery clip along the side. Pay
attention not to pull the wires.
3) If necessary, remove the old batteries and place the new
ones: 2x LR03 Alkaline long life 1.5 V.
4) Click the battery clip into the remote control and close the
cover.
5) It might be possible that you have to set the transmission code after changing the batteries (see 10.4.3).
Note
Batteries are chemical waste and should be disposed in accordance with local regulations.
Fig. 28
UK/IRL
> > > > 47
12 Cleaning and service instructions
Important: Turn off the fire and allow it to cool down before commencing cleaning.
It is recommended that the fire is inspected/serviced, by a competent person at least once a year.
To maintain the finish on the trim wipe with soft damp cloth only. Do not use abrasive cleaners, polish or solvents as these can damage the surface finish.
UK/IRL
48 < < < <
13 Disposal of packaging and appliance
The appliance packaging is recyclable. The packaging could include the following materials:
- cardboard;
- CFC-free foam (soft);
- wood;
- plastic;
- paper.
These materials should be disposed responsibly and in conformity with government regulations.
Batteries are considered chemical waste. The batteries should be disposed of responsibly and in conformity with government regulations. Remove the batteries before disposing of the remote control.
Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities.
UK/IRL
> > > > 49