Page 2
Use this manual with the following models
1506-080, 1506-081, 1506-082, 1506-083, 1506-084, 1506-085, 1506-086, 1506-090, 1506-091, 1506-092, 1506-093, 1506-094, 1506-095, 1506-096, 1504-080, 1504-082, 1504-083, 1504-084, 1504-085 and 1504-086 Digital Keypad Entry Devices with circuit board 1506-010, Rev G and Higher.
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
Permission is granted to reproduce pages 24 and 25 in this manual.
Page 3
Page 4
Table of Contents
IMPORTANT NOTICES............................................................................................................................................6
SECTION 1 – INSTALLATION
1.1 Mounting Dimensions...............................................................................................................................7
1.2 Wiring .......................................................................................................................................................9
1.3 Wire Diagram............................................................................................................................................10
1.4 Terminal Identification ..............................................................................................................................11
1.5 Aiphone Intercom Station Connections....................................................................................................12
1.6 Slave Keypad Wiring................................................................................................................................13
SECTION 2 – PROGRAMMING
2.1 Master Code.............................................................................................................................................15
2.2 Relay Strike Time.....................................................................................................................................15
2.3 X-Strikes Programming ............................................................................................................................15
2.4 Programming Four-digit Entry Codes.......................................................................................................16
2.5 Erasing Individual Four-digit Entry Codes................................................................................................16
2.6 Erasing ALL Four-digit Entry Codes.........................................................................................................16
2.7 Four-digit entry Code Divide Number.......................................................................................................16
2.8 Programming Five-digit Entry Codes .......................................................................................................17
2.9 Erasing Individual Five-digit Entry Codes.................................................................................................17
2.10 Erasing ALL Five-digit Entry Codes .........................................................................................................17
2.11 Five-digit Entry Code Divide Number.......................................................................................................17
2.12 Hold Boundary Programming...................................................................................................................18
2.13 Time Zone 1 Boundary Programming ......................................................................................................18
2.14 Time Zone 2 Boundary Programming ......................................................................................................18
SECTION 3 – OPERATING INSTRUCTIONS
3.1 Four-digit Entry Codes..............................................................................................................................19
3.2 Five-digit Entry Codes..............................................................................................................................19
3.3 Request to Exit Input................................................................................................................................19
3.4 Door Open Input.......................................................................................................................................19
3.5 Hold Feature Operation............................................................................................................................20
3.6 Time Zone Operation ...............................................................................................................................21
SECTION 4 – APPENDIX
4.1 Troubleshooting........................................................................................................................................23
4.2 Data Tables..............................................................................................................................................24
Log Sheet .................................................................................................................................................................25
Page 5
2.15
IMPORTANT NOTICES
Prior to starting the installation, become familiar with the instructions, illustrations and wiring diagrams in this manual.
Never mount this device to a moving gate or gate panel, or next to a gate that causes vibration to the fence, such as a spring-loaded pedestrian gate. Continuous vibration from moving or slamming gates can cause damage to the unit in time.
WARNING! If this entry system is used to control a vehicular gate with
an automatic gate operator, the entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.
Always disconnect power when performing service on the system.
If the unit is mounted outdoors, be sure that the wiring to the unit is designed for direct under-
ground burial, even if the wire is run inside a conduit.
Surge suppression is recommended on the low voltage input power line.
Instruct the end user on the safe and proper operation of this device.
Instruct the end user to read and follow these instructions. Instruct the end user to
never let children play with or operate any access control device. This Owner’s Manual is the property of the end user and must be left with them when installation is complete.
Page 6
SECTION 1 - INSTALLATION

1.1 Mounting

Surface mount units can be mounted directly to a wall or pilaster, or they can be mounted using a gooseneck mounting post (p/n 1200-045 or 1200-046).
5.25
4.375
2.5
1 2 3
654
6.25
2.5
.875 987 #0
*
.25
3.375
1506 Surface Mount
10.0 5.25
2.5
2.5
1
7 8 9
32
654
#0*
6.125
.875
3.0
2.875
.875 Dia
1.31
1.25
5.0
Model 1504 Surface Mount
Page 7
The flush mount keypad consist of two parts, the keypad and the rough-in box. Mount the rough-in box and wiring first, and then install the keypad into the rough-in box.
.25
1 2 3
*
7.125
8.375
654 987 #0
4.0
6.625
4.375
.875
4.25
.875
.875
5.375
4.25
10-24 STUD
2.56
.75
1.25
4.375
FLUSH
MOUNT
KEYPAD
2.0
.25
7.0
2.252.251.25
4.05.625
.875
.25
2.875
3.875
1.875
.75
2.125
ROUGH
IN
BOX
ROUGH-IN BOXFLUSH KEYPAD
Page 8