FAAC 1150-080 User Manual

Owner’s Manual
Overhead Gate Operator
EXIT
REVERSE
LOOP
GATE FORCED
NO NC
LOOP
LIMIT
LIMIT
PART
PUSH TO OPERATE
REV SENSE
OPEN
TIME
REV SENSE
CLOSE
1
2 3 4 1
ON
technician use only
2 3 4 5 6 7 8
ON
1150
1150
Copyright 2011 DoorKing, Inc. All rights reserved.
SPECIFICATIONS
Class of Operation Model 1150 - UL325 Class II, III and IV Type of Gate Vehicular high traffic overhead gates only.
Horsepower/ Voltage / Phase ½ HP - 115 VAC - 60 Hz. Single-Phase Current 5.4 Amps Max Gate Dimensions Height - 14 Feet, Width - 25 Feet Gear Reduction 40:1 Worm gear in a continuous oil bath. Chain Type #40
Cycles Per Hour Continuous Duty Speed Approximately 10 inches per second Entrapment Protection Primary - Inherent entrapment sensing
system (Type A) Secondary - Provision for connection of
a non-contact and/or contact sensor (Type B1 and/or B2)
Dimension A
Rail Part Number Max. Gate Height Dimension A
1150-120
1150-121
1150-122
1150-123
8 feet
10 feet
12 feet
14 feet
12 feet 5 inches
14 feet 5 inches
16 feet 5 inches
18 feet 5 inches
1150-065-F-1-11
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
1
TABLE OF CONTENTS
SPECIFICATIONS 1
Overhead Gate Protection Gate Construction Important Safety Instructions Instructions regarding intended installation: Important Notices UL325 Entrapment Protection Glossary
SECTION 1 - INSTALLATION 8
1.1 Attach Rails to Powerhead
1.2 Manual Release and Chain Connection
1.3 Adjust Chain Tension
1.4 Attach Gate Bracket
1.5 Attach Header Bracket
1.6 Mount Powerhead and Finish Installation
10-11
SECTION 2 - WIRING 12
2.1 Conduit Requirements
2.2 High Voltage Wire Run
2.3 High Voltage Terminal Connection
2.4 Main Terminal Description
2.5 Control Wiring
2.6 Secondary Entrapment Protection Wiring
2.7 Loop Detector Wiring
12 13 13 14 15 16
17
3 4 4 4 5 6
7
8 8 9 9 9
SECTION 3 - ADJUSTMENTS 18
3.1 Circuit Board Adjustments
3.2 DIP-Switch Descriptions and Functions
3.3 Limit Sensor Adjustments
3.4 Inherent Reverse Sensors Adjustment
SECTION 4 - TECHNICAL INSTRUCTIONS 22
4.1 Maintenance Schedule
4.2 Diagnostics Check
4.3 Troubleshooting
4.4 Accessories 1150 Wiring Schematic
2
18 19
20
21
22 22-23 23-24
25 26
1150-065-F-1-11
Overhead Gate Protection
Reverse Loop
Minimizes the potential of the gate closing when a vehicle is present. Placement of loops is dependent
C
on the application.
B
A
C
Reverse Loop
Minimizes the potential of the gate closing when a vehicle is present. Placement of loops is dependent on the application.
Separate Pedestrian
Walkway
Located so pedestrians cannot come in contact
Automatic Exit Loop
(Optional) will provide an open command to the gate operator when a vehicle is exiting the property.
A
Non-contact Sensor
Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. Actual placement of sensors depends on the installation requirements. Position non-contact sensors so that an entrapment cannot occur at the lower travel of the gate. Do not place the sensors so high that a person could be trapped under the gate without activating the sensor.
with the vehicular gate.
1150-065-F-1-11
B
Contact Sensor
Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. Install the contact sensors
C
at the bottom edge of the gate. Additional
Moving Gate Can Cause Serious Injury or Death
KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance.
contact sensors may be added for additional protection where entrapment zones exist.
C
Warning Signs
Permanently mounted and easily visible from
A
either side of the gate.
B
Moving Gate Can Cause Serious Injury or Death
KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance.
3
Gate Construction
Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or
www.astm.org.
Important Safety Instructions
WARNING - To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS!
Instructions regarding intended installation:
Install the gate operator only if:
1. The operator is appropriate for the construction of the gate and the usage class of the gate.
2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2 ¼ inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
3. All exposed pinch points are eliminated or guarded.
4. Guarding is supplied for exposed rollers.
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate
access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures
when opening and closing to reduce the risk of entrapment. Swinging gates should not open into public access areas.
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not
over-tighten the operator clutch, pressure relief valve or reduce reversing sensitivity to compensate for a damaged gate.
For gate operators utilizing Type D protection:
1. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving.
2. A warning placard shall be placed adjacent to the controls.
3. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed.
4. No other activation device shall be connected.
Controls intended for user activation must be located at least ten feet (10’) away from any moving part of the gate and
where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use.
The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not
cause the operator to start.
A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
For gate operators utilizing a non-contact sensor:
1. See the instructions on the placement of non-contact sensors for each type of application.
2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction.
3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier.
4
1150-065-F-1-11
For gate operators utilizing contact sensors:
1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
5. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstructions. A wireless contact sensor shall function under the intended end-use conditions.
6. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
Important Notices
Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people underestimate the power of these systems and do not realize the potential hazards associ­ated with an incorrectly designed or installed system. These hazards may include:
Pinch points
Entrapment areas
Reach through hazards
Absence of entrapment protection devices
Improperly located access controls
Absence of vehicle protection devices
Absence of controlled pedestrian access In addition to these potential hazards, automated vehicular gate systems must be installed in accordance with the UL-325
Safety Standard and the ASTM F2200 Construction Standard. Most lay persons are unaware of, or are not familiar with, these standards. If an automated vehicular gate system is not properly designed, installed, used and maintained, serious injuries or death can result. Be sure that the installer has instructed you on the proper operation of the gate and gate operator system. Be sure that the installer has trained you about the basic functions of the required reversing systems associated with your gate operating system and how to test them. These include reversing loops, inherent reversing system, electric edges, photoelectric cells, or other external devices.
This Owner’s Manual is your property. Keep it in a safe place for future reference.
Be sure that all access control devices are installed a minimum distance of 10 feet away from the gate and gate
operator, or in such a way that a person cannot touch the gate or gate operator while using the device. If access control devices are installed in violation of these restrictions, immediately remove the gate operator from service and contact your installing dealer.
Loops and loop detectors, photo-cells or other equivalent devices must be installed to prevent the gate from
closing on vehicular traffic.
The speed limit for vehicular traffic through the gate area is 5 MPH. Install speed bumps and signs to keep
vehicular traffic from speeding through the gate area. Failure to adhere to posted speed limits can result in damage to the gate, gate operator, and to the vehicle.
Be sure that all persons who will use the gate system are familiar with the proper use of the gate and gate
operator and are familiar with the possible hazards associated with the gate system.
Be sure that warning signs are permanently installed on both sides of the gate in an area where they are fully
visible to traffic.
It is your responsibility to periodically check all entrapment protection devices. If any of these devices are
observed to function improperly, remove the operator from service immediately and contact your installing or servicing dealer.
Follow the recommended maintenance schedule.
Do not allow children to play in the area of the operator or to play with any gate-operating device.
To remove the gate operator from service, operate the gate to the full open position and then shut off power to
the operator at the service panel.
1150-065-F-1-11
5
UL325 Entrapment Protection
Class I
A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
Class II
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public.
STA
TE
PR
ISON
Class III Class IV
A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
This table illustrates the entrapment protection requirements for each of the four UL325 classes.
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
UL325
Classifications
Class I and II
Class III
Class IV
A - Inherent entrapment protection system. B1 - Provision for connection of, or supplied with, a non-contact sensor (photoelectric sensor or the equivalent).
When used as the PRIMARY device, must be monitored. B2 - Provision for connection of, or supplied with, a contact sensor (edge device or the equivalent).
When used as the PRIMARY device, must be monitored.
C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain
opening or closing motion of the gate.
E - An inherent audio alarm.
6
Horizontal Slide, Vertical Lift, Vertical Pivot Swing and Vertical Barrier (arm)
Primary Protection
A B1, B2 or D A, B1, B2, C or DA or C
A, B1 or B2 A, B1, B2, D or E A, B1, B2, C or DA, B1, B2 or C
A, B1, B2 or D A, B1, B2, D or E A, B1, B2, C, D or EA, B1, B2, C or D
Secondary Protection Primary Protection Secondary Protection
1150-065-F-1-11
Glossary
GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage
barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I - A vehicular gate operator (or system) intended for use in a home
of one-to four single family dwelling, or garage or parking area associated therewith.
COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR - CLASS II - A vehicular gate operator (or system)
intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail store, or other building servicing the general public.
INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III - A vehicular gate operator (or system)
intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV - A vehicular gate operator (or system) intended for use in
a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
VEHICULAR BARRIER (ARM) OPERATOR (OR SYSTEM) - An operator (or system) that controls a cantilever type device (or
system), consisting of a mechanical arm or barrier that moves in a vertical arc, intended for vehicular traffic flow at entrances or exits to areas such as parking garages, lots or toll areas.
VEHICULAR HORIZONTAL SLIDE-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a
gate which slides in a horizontal direction that is intended for use for vehicular entrance and exit to a drive, parking lot, or the like.
VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which
moves in an arc in a horizontal plane that is intended for use for vehicular entrance and exit to a drive, parking lot, or the like.
SYSTEM - In the context of these requirements, a system refers to a group of interacting devices intended to perform a
common function.
WIRED CONTROL - A control implemented in a form of fixed physical interconnections between the control, the associated
devices, and an operator to perform predetermined functions in response to input signals.
WIRELESS CONTROL - A control implemented in means other than fixed physical interconnections (such as radio waves or
infrared beams) between the control, the associated devices, and an operator to perform predetermined functions in response to input signals.
INHERENT ENTRAPMENT PROTECTION SYSTEM - A system, examples being a motor current or speed sensing system,
which provides protection against entrapment upon sensing an object and is incorporated as a permanent and integral part of the operator.
EXTERNAL ENTRAPMENT PROTECTION DEVICE - A device, examples being an edge sensor, a photoelectric sensor, or
similar entrapment protection device, which provides protection against entrapment when activated and is not incorporated as a permanent part of an operator.
ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury.
1150-065-F-1-11
7
SECTION 1 - INSTALLATION
1.1 Attach Rails to Powerhead
Secure rails with 4 bolts, nuts and lock washers.
CAUTION
FRAGILE POWERHEAD!
1.2 Manual Release and Chain Connection
Cut wire ties and route chain around gear reducer’s sprocket and through unlocked carriage assembly (To unlock assembly, use key to unlock release ring, pull ring up and rotate 45° to release spring loaded chain catch). Connect chain together with double master link.
1
Unlock
IMPORTANT: The carriage assembly’s
spring loaded chain catch will only lock into place in the double master chain link.
Pull and Turn Ring
2
8
Sprocket
Double Master Chain Link
1150-065-F-1-11
1.3 Adjust Chain Tension
Do not overtighten chain. Make adjustments equally on both sides of rails. Chain will need final adjustment after operator has been mounted. Chain will stretch over time and will need to be tightened.
Do not let chain touch steel rail separators.
Approximate chain tension, front rail removed for illustration.
EXIT
LOOP
REVERSE
LOOP
LIMIT
LIMIT
PART
GATE FORCED
REV SENSE
OPEN
TIME
DELAY
REV SENSE
CLOSE
1ON2341ON23456 78
NO NC
Chain must be centered between rails.
Return wheel must be centered between rails.
Chain tension adjustment. Adjust equally on both sides of rails.
1.4 Attach Gate Bracket
Install the gate bracket on the top rail of the gate by bolting or welding. Bracket must be mounted level
and centered on gate!
Header
Check all local building codes and ordinances to ensure compliance.
ate
Rail
Top G
1.5 Attach Header Bracket
Center the header bracket above the top of the gate bracket a minimum of 2.5 inches from the bottom of the header bracket. Check the gate’s opening swing path, some gates will swing open higher than the bottom of the header and could hit the rails if they are mounted too low. Header bracket must be securely mounted.
Side View of Gate Opening Alternate Mounting
Header Bracket Assembly
Header
Header Bracket
Header
2.5” Minimum 2.5” Minimum
Gate Bracket
Install the header bracket centered above the gate bracket with lag bolts, anchor sleeves or welding.
Header Bracket must be mounted level!
Ceiling
Header Bracket
Gate Bracket
It is recommended that the header bracket be isolated from the ceiling by use of rubber shock mount.
1150-065-F-1-11
9
1.6 Mount Powerhead and Finish Installation
Connect rails to header bracket. The powerhead must be protected from damage. Use the shipping box and packing material to set the powerhead on while connecting the rails to the header bracket.
FRAGILE POWERHEAD!
CAUTION
Packing Material
Header Bracket Assembly
Mount Powerhead Directly to Ceiling
Ceiling
Install the powerhead with lag bolts or anchor sleeves.
Rails must be mounted level!
Mount Powerhead Using a Ceiling Extension Bracket
Ceiling
Ceiling extension bracket must be fabricated (2” wide L angle steel is recommended).
SHIPPING BOX
Install the powerhead with lag bolts or anchor sleeves.
Rails must be mounted level!
10
1150-065-F-1-11
Connect Carriage Arm
Carriage assembly must to be unlocked. After connecting the arm, manually raise and lower the gate, be sure the gate is operating smoothly and is not binding anywhere. Any interference must be corrected now.
Fill Mark
IMPORTANT: The carriage assembly’s spring
loaded chain catch will only lock into place in the double master chain link.
Install Breather Cap in Gearbox
Install breather cap after operator has been mounted. Check oil level, use Mobil SHC-629 synthetic gear oil or equivalent.
IMPORTANT: Gearbox should be filled to fill mark only.
Do not overfill.
Final Chain Adjustment
Check that the chain is not rubbing on the steel rail separators. Final tension adjustment might be needed.
Installation of Warning Signs
This DoorKing Overhead Gate Operator is shipped with two warning signs. The purpose of the warning sign is to alert uninformed persons, and to remind persons familiar with the gate system, that a possible hazard exists so that appropriate action can be taken to avoid the hazard or to reduce exposure to the hazard.
Permanently install the supplied warning signs in locations so
that the signs are visible by persons on both sides of the gate.
Use appropriate hardware such as wood or sheet metal screws
(not supplied) to install the warning signs.
Steel Rail Separator Steel Rail Separator
1150-065-F-1-11
11
SECTION 2 - WIRING
Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.
Since building codes vary from city to city, we highly recommend that you check with your local building department prior to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local code requirements.
THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!!
2.1 Conduit Requirements
3/4 Inch rigid conduit minimum. Use sweeps for bends.
NO NC
1ON23 41ON23 45 6 7 8
REV SENSE
CLOSE
TIME
DELAY
OPEN
GATE FORCED
technician use only
PUSH TO OPERATE
REV SENSE
LIMIT
LIMIT
PART
EXIT
LOOP
REVERSE
LOOP
3/4 Inch Flexible
Dry Conduit.
Loop Lead-In Wires
High Voltage Power
Low Voltage Control Wires
The conduit requirements are for a typical overhead gate operator installation. The conduit requirements for your
application may vary from this depending on your specific needs.
Use only sweeps for conduit bends. Do not use 90° connectors as this will make wire pulls very difficult and can
cause damage to wire insulation.
We suggest that minimum ¾-inch conduit be used.
Be sure that all conduits are installed in accordance with local codes.
12
1150-065-F-1-11
2.2 High Voltage Wire Run
The distance shown in the chart is measured in Feet from the operator to the power source. If power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is used, a separate junction box must be installed for the operator connection. The wire table is based on stranded copper wire. Wire run calculations are based on a 110 VAC power source with a 3% voltage drop on the power line, plus an additional 10% reduction in distance to allow for other losses in the system.
This table illustrates the high voltage wire size and distance requirements.
Model
Type
1150
Voltage
Required
Amps
Required
12 AWG 10 AWG 8 AWG 6 AWG
115 5.4 170 275 460 685
Wire Size / Distance in Feet
Never run high voltage and low voltage wires in the same conduit. Keep them in separate conduits.
2.3 High Voltage Terminal Connection
NO NC
technician use only
PUSH TO OPERATE
1ON2 3 41ON2 3 4 5 6 7 8
TIME
REV SENSE
DELAY
CLOSE
OPEN
REV SENSE
GATE FORCED
ON/OFF Power Switch
High Voltage Conduit
1150-065-F-1-11
LIMIT
LIMIT
PART
EXIT
LOOP
REVERSE
LOOP
Chassis Ground
Neutral - White
DANGER
HIGH VOLTAGE!
Route incoming high voltage power through conduit and into the operator as shown.
Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring.
Connect power wires as shown.
It is recommended that a surge suppressor be installed on the high voltage power lines to help
protect the operator and circuit board from surges and power fluctuations.
Hot - Black
13
2.4 Main Terminal Description
1 2
4 5 6 7 8
1
3 4 5 6 7 8
1
3 4 5 6 7 8 1
2 3
6 7 8
1 2 3 4 5 6
8
1
2
1. LOW VOLTAGE COMMON
2. NOT USED
lf SW 1, switch 3 is ON,
this is an open input.
lf SW 1, switch 3 is OFF,
this terminal becomes the logic output of the loop
4
detector plugged into the exit loop plug (DoorKing Loop Detectors Only).
ON
3
SW 1
3
4
5
6
7
8
9
10
11
12
3. NOT USED
4. OPEN INPUT/ EXIT LOOP LOGIC OUTPUT
5. FULL OPEN/CLOSE INPUT
6. NOT USED
7. STANDARD REVERSE/STOP INPUT
8. OPEN INPUT
DoorKing 3-Button Control Station Only
9. CLOSE INPUT
DoorKing 3-Button Control Station Only
10. GATE TRACKER - DATA
11. GATE TRACKER - BUSY
12. DRY RELAY CONTACT
When gate is closed, this input will open
gate.
When gate is open and auto close
5
timer SW 1, switch 2 is turned ON, input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 2 is turned OFF, input will close gate.
When gate is closing, input will
reverse gate.
7
When gate is closed or in the opening cycle,
this input has no effect on gate operator.
When gate is open and auto close
timer SW 1, switch 2 is turned ON, input will re-set and hold timer.
ON
2
SW 1
ON
2
ONC
14
13
14
15
16
17
18
19
20
13. DRY RELAY CONTACT
14. 24 VAC 250ma Max.
Radio Receiver Power and/or Gate Tracker Only
15. NOT USED
16. MOTOR
17. MOTOR
18. 120 VAC HOT
19. 120 VAC NEUTRAL
20. EARTH GROUND CHASSIS GROUND
When gate is open and auto close
timer SW 1, switch 2 is turned OFF, input will prevent gate from closing.
When gate is closing and SW 1,
switch 7 is turned OFF, input will reverse gate.
When gate is closing and SW 1,
switch 7 is turned ON, input will stop gate.
Operation of relay is dependent on
12
setting of SW 1, switches 4 and 5. Relay contacts can be set for Normally Open (NO) or Normally Closed (NC) operation.
Relay contact rating is 1 amp maximum at 24-volts DC.
7
4 5
NC
SW 1
ON
SW 1
ON
SW 1
1150-065-F-1-11
NO
2.5 Control Wiring
Controls must be installed far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet. Use a low voltage surge suppressor, DoorKing P/N 1878-010 if low voltage wire runs exceed 1000 feet. All inputs to the main terminal must be Normally Open (NO).
Dry-Contact
Key SwitchLock Boxes Push Button
Telephone Entry
Note: All stand-alone and telephone entry devices must use a separate power source.
Stand-Alone
Keypad
Stand-Alone Card Reader
NO NC
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
Com
Open
Close
3-Button Control Station
Com
Com
Relay
24 Volt
Radio Receiver
Entrapment Protection
Non-contact sensor
Terminal 5 Optional
A
Contact sensor
B
A
B
These systems can be used together.
1150-065-F-1-11
Gate Tracker
DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected. This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the gate has struck anything during the open or close cycle, power interruptions, etc. For more detailed information refer to the Tracker Installation and Wiring Manual, DoorKing P/N 2351-010.
15
2.6 Secondary Entrapment Protection Wiring
Secondary entrapment prevention devices must be installed to insure a safe operating environment and reduce the risk of personnel entrapment. Secondary entrapment prevention may be provided by a combination of both type sensors (UL 325 Type B1 and B2).
Use only UL listed (or equivalent) sensors.
Sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a
moving gate or barrier. Additional sensors should be added for additional protection where entrapment zones exist. Actual placement of sensors is dependent on the installation requirements.
Inputs from sensors to circuit board are Normally Open (NO).
Disconnect power to gate operator before installing the sensors.
Non-Contact Sensor (Type B1)
Photo-cell should be placed so that an entrapment cannot occur at the lower travel of the gate. Do not place the
photo-cell so high that a person could be trapped under the gate without activating the photo-cell.
If high bed vehicles access the gate, a second photo-cell should be placed so that the photo-beam cannot scan
under the vehicle.
Photo-cells may require separate
power depending on model used.
Typical Vehicles (Single Beam)
NO NC
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
Com
High Bed Vehicles (Multiple Beams)
N. O.
Contact Sensor (Type B2)
Hardwired contact sensors must be located and wiring arranged so that the communication
between the sensor and the gate operator is not subjected to mechanical damage.
Additional contact sensors should be added where multiple entrapment zones may exist.
Junction
Box
Avoid interference with gate hardware.
16
1150-065-F-1-11
2.7 Loop Detector Wiring
Loop detectors must be installed to prevent the gate from accidentally closing on vehicles that may be in the path of the gate.
Install 9410-101 Single Channel or 9409-101 Dual Channel DoorKing plug-in loop detectors (Sold separately).
If using external loop detectors, use only UL listed (or equivalent) detectors. Use a separate power supply for
external loop detectors. Inputs to circuit board are Normally Open (NO).
Disconnect power to gate operator before installing any loop detectors.
Automatic exit loop lead in wires are twisted approx. 6 twists per foot.
9410
9410
ON
2 3 4 5 6 7 8
EXIT LOOP
ON
1
TIME DELAY
REV SENSE CLOSE
2 3 41
LIMIT LIMIT PAR T
REVERSE LOOP
REV SENSE
OPEN
GATE FORCED
Reverse loop lead in wires are twisted approx. 6 twists per foot and are wired in series.
NO NC
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
Normally Open
6
7
External Loop Connections
8
9
1150-065-F-1-11
Automatic Exit Loop
Reverse Loop
Reverse Loop
Loop layout shown is for a typical overhead gate application
with two-way traffic, or one-way exit only traffic.
Refer to the Loop Information Manual (available from
www.dkaccess.com) for more information on loops and loop detectors.
17
SECTION 3 - ADJUSTMENTS
1
3 4 5 6 7 8
2 3 4
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator is complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
3.1 Circuit Board Adjustments
ON
1
Set the DIP-switches on the
circuit board to the desired setting. See switch-setting charts on next page.
2 3 4 5 6 7 8
1 2 3 4
SW 1
SW 2
ON
Self test (when turned
1
on) SW 2, switch 1.
SW 2
CAUTION
Do not run self-test with the operator connected to the gate. The drive chain must be discon­nected from the operator to run the self-test. This feature is designed for bench testing ONLY.
ON
Auto Close TimerSelf TestDIP-Switches
Auto close timer (when
turned on) SW 1, switch 2.
Adjust from 1 second (full counter clockwise) to approximately 23 seconds (full clockwise).
ON
2
SW 1
123
EXIT
REVERSE
Loop Detector
9410
Loop Detector
9410
EXIT LOOP
LIMIT LIMIT PAR T
REVERSE LOOP
REV SENSE
OPEN
GATE FORCED
TIME DELAY
REV SENSE CLOSE
ON
2 3 4 5 6 7 8
1
2
3
ON
1 2 3 41
4
5
6
7
8
9
10
11
12
NO NC
13
14
15
16
Dry Relay Contact
17
C.
18
19
N.
N.O.
20
Reverse Sensors
Adjust reversing sensitivity
for OPEN and CLOSE directions.
OPEN CLOSE
Min Max
18
Min Max
Dry relay contacts
(terminals 12-13) can be set for Normally Open (NO) or Normally Closed (NC) operation by placing the relay shorting bar on the N.O. or N.C. pins respectively.
1150-065-F-1-11
3.2 DIP-Switch Descriptions and Functions
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
SW 1 (Top 8 Switches)
Switch Function Setting Description
Changes open/close direction operator should cycle open upon initial power up.
1
2
3
Change
Direction
Auto-Close
Timer
EXIT Loop
Port
4-OFF
4 and 5
Relay
4-OFF
4-ON 4-ON
6
7
8
Switch 1 Sets direction of the operator so that the operator cycles open upon initial power up and open command. If the operator begins to
cycle close upon initial power up and open command, turn power off and change the setting on this switch.
Switch 2 Turns the auto close timer on or off. Maximum time that the close timer can be set for is approximately 23 seconds. Switch 3 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT port will be sent directly to the
microprocessor of a single slide or overhead gate operator’s circuit board, or if the output is directed to the Main Terminal 4 where it can then be connected with a secondary slide gate operator ONLY. Turn switch ON, Main Terminal 4 is not used for an overhead gate operator.
Switches 4-5 These work in conjunction with each other and determine when the relay on the circuit board will be activated. This relay can be
used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a green light when the gate is full open.
Switch 6 Spare switch, not used. Leave in OFF position. Switch 7 Determines if an input to terminal 7 will reverse and open or stop then close a closing gate. If this switch is set to stop then close
(ON), input to terminal 7 will stop closing gate, once input is removed (cleared), the gate will continue to close. This is typically used to help prevent tail-gating.
Switch 8 Turning quick-close on will cause the auto close timer to close the gate after 1 second, regardless of the timer’s setting. This will also
cause an opening gate to stop, then close when the reverse (loop) inputs have been cleared by vehicle no matter how far the gate has opened. This feature helps prevent an unauthorized second vehicle from driving through a single authorized long open/close cycle for large gates.
Not Used
Reverse and Open
Stop then Close
Quick Close
OFF
ON
OFF
ON
OFF
ON
5-OFF
5-ON
5-OFF
5-ON
OFF OFF
ON
OFF
ON
Normal setting.
Auto-close timer is OFF. Manual input (push control button) required to close gate. Auto=close timer is ON. Adjustable from 1-23 seconds.
EXIT loop port output is sent to terminal 4 for secondary slide gate operator only. Normal setting. EXIT loop port output is sent directly to circuit board. Relay activates when gate is full open. Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates when gate is opening and closing.
Normal setting. Normal Setting. During close cycle, input to terminal 7 will reverse and open gate.
During close cycle, input to terminal 7 stops gate, after input removed, closes gate. Normal Setting. Normal gate operation.
Opening gate will stop, then close as soon as all reversing inputs (loops, beams) have been cleared by vehicle regardless of how far the gate has opened.
SW 2 (Bottom 4 Switches)
Switch Function Setting Description
Normal Setting.
1
2
3
4
Switch 1 This switch must be in the OFF position for normal operation. The self-test feature checks various functions of the operator. CAUTION
- Do not run self-test with the operator connected to the gate. The drive chain must be disconnected from the operator to run the self-test.
Switch 2 Spare switch, not used. Leave in OFF position. Switch 3 Sets the circuit board to function with slide gate operators (switch OFF) or overhead gate operators (switch ON). This switch must be
left in the ON position for model 1150 Overhead Gate Operator.
Switch 4 Spare switch, not used. Leave in OFF position.
1150-065-F-1-11
Self Test
Not Used
Slide Gate
Overhead Gate
Not Used
OFF
Run self test - bench testing only. Operator must not be connected to gate!
ON
Normal setting.
OFF
OFF
Normal setting. Must be in the ON position for overhead gate operator.
ON
Normal setting.
OFF
19
3.3 Limit Switch Adjustments
4 5 6 7 8
1 2
4
Basic DIP Settings
Start-up direction should be ON.
ON
1 2 3
SW 1, switch 1.
Auto close timer (when turned
on) SW 1, switch 2.
SW 1, switch 3 should be ON.
SW 1
SW 2, switch 3 should be ON.
ON
3
SW 2
Setting Timer
Adjust from 1 second (full counter clockwise) to approximately 23 seconds (full clockwise).
123
Turn power off.
Push and hold locking plate tab.
Adjust limit nuts at full open and
full close gate positions.
Release locking plate tab to secure limit nuts.
Turn power on. Cycle gate and check positions.
Re-adjust if necessary.
Close Limit LED Open Limit LED
EXIT LOOP
REVERSE LOOP
Open Limit Nut
Push and Hold Tab
LIMIT LIMIT PART
PUSH TO OPERATE
technician use only
REV SENSE
OPEN
GATE FORCED
TIME DELAY
OPEN
2 3 4 5 6 7 8
1 2 3 41
REV SENSE CLOSE
CLOSE
Close Limit
ON
ON
NO NC
Nut
20
1150-065-F-1-11
3.4 Inherent Reverse Sensors Adjustment
This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sense an obstruction in either the opening or closing gate cycles and will cause the gate to reverse direction should an obstruction be encountered. For this system to function correctly, the gate must be properly installed and work freely in both directions.
After the limit switches have been adjusted, activate the gate operator by pushing “Push to Operate” button.
1
PUSH TO OPERATE
While the gate is OPENING, slowly rotate the reverse open sensor clockwise until the
2
gate stops and the Open LED will light up, then rotate the sensor 1/8 turn counter­clockwise. After the gate has stopped, push “Push to Operate” button again to continue the open cycle of the gate. Auto close timer (If on) will then close the gate, completing the gate’s open/close cycle.
OPEN CLOSE
NOTE: Clockwise INCREASES the reverse sensitivity.
Counter-clockwise DECREASES the reverse sensitivity.
technician use only
Min Max
While the gate is CLOSING, slowly rotate the reverse close sensor clockwise until the
3
Min Max
SensitivitySensitivity
gate stops and the Close LED will light up, then rotate the sensor 1/8 turn counter­clockwise. The gate will automatically reverse direction and open. Auto close timer (If on) will then close the gate, completing the gate’s open/close cycle.
NOTE: You may have to repeat these
steps a few times to get the gate to completely cycle open and closed.
Test Reverse Sensors
Place an immobile object along
1
the path of the gate so that the gate strikes it while opening. Gate must stop! Re-adjust Open sensor if necessary.
Place an immobile object along
2
the path of the gate so that the gate strikes it while closing. Gate must reverse direction and open! Re-adjust Close sensor if necessary.
EXIT LOOP
REVERSE LOOP
LIMIT LIMIT PART
PUSH TO OPERATE
technician use only
REV SENSE
OPEN
GATE FORCED
TIME DELAY
ON
2 3 4 5 6 7 8
ON
1 2 3 41
REV SENSE CLOSE
NO NC
1150-065-F-1-11
21
SECTION 4 - TECHNICAL INSTRUCTIONS
Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks.
4.1 Maintenance
When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can be identified and corrected.
Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result in serious injury or death should they become entrapped in the gate.
When servicing the gate operator, be sure that the AC input power is disconnected.
Operator
Component
Chain
Fire Dept.
Gate
Loop(s) Gearbox Oil
Primary Reverse System
Release
Secondary Reverse Device
Complete System
Maintenance
Check for sagging, chain must not rub against steel rail separators. Tighten if necessary. Grease chain if necessary.
Check emergency vehicle access device for proper operation.
Inspect for damage. Check gate hinges for wear and grease if necessary.
Check vehicular reverse and exit loops for proper operation.
Check oil level, should be at fill mark. Fill if necessary. Use Mobil SHC-629 synthetic gear oil or equivalent.
Check that the gate reverses on contact with an object in both the opening and closing cycles. Adjust the reversing sensors if necessary.
Check manual release for proper operation.
Check secondary (external) reverse device(s) stop or reverse the gate when activated.
Complete check of gate and gate operating system.
Monthly Interval
6 3 12
✓ ✓
4.2 Diagnostics Check
Have the following diagnostic tools available: VOM meter with minimum voltage memory or min-max range to check voltage and continuity. Meg-ohm meter capable of checking up to 500 megohms of resistance to properly check ground loop integrity. A malfunction can be isolated to one of the following:
Gate Operator
Loop System
External Keying Devices
Use caution when checking high voltage areas: high voltage input terminal and the main terminals 16 through 19, the motor capacitor and the motor.
Check the input indicator LEDs. They should only come ON when an external keying device (card reader, push button, etc.) is activated. If any of the input LEDs are ON continuously, the gate will not operate. Disconnect the external keying devices one at a time until the LED goes OFF.
22
1150-065-F-1-11
A malfunction in a loop or loop detector can cause the gate operator to hold open, or not detect a vehicle when it is present over the loop. Pull the loop detector circuit boards from the loop ports on the operator circuit board. If the malfunction persists, the problem is not with the loop system. For more information refer to the loop detector instruction sheet and the DoorKing Loop and Loop Detector Information Manual.
Check to be sure that there are no shorted or open control wires from the external keying devices to the gate operator. If a external keying device fails to operate the gate, momentarily jumper across terminals 6 and 14 on the operator circuit board. If the gate operates, this indicates that a problem exist with the external keying device and is not with the operator. Check the high voltage supply. A voltage drop on the supply line (usually caused by using too small supply voltage wires) will cause the operator to malfunction. Refer to the wire size chart on page 13.
4.3 Troubleshooting
Symptom Possible Solution(s)
Operator will not run – power LED is OFF.
Operator will not run – power LED is ON.
Gate opens a short distance, stops and reverses.
Check that power to the operator is turned ON.
Transformer may be overheated. Turn power off and allow board to cool for several minutes then
retest. Check for low 120 VAC power and low voltage shorts.
Check for 120 VAC at terminals 18 and 19. If voltage measures 0, check power. If voltage measures
OK, check the terminal strip or replace the circuit board.
If a photo-cell is used as a secondary entrapment prevention device, check to be sure that the beam
is not blocked.
Momentarily jumper terminal 1 to terminal 5 or press “Push to Operate” button. If the input LED
does not come ON, check the terminal strip or replace the circuit board. If LED does come ON, proceed to next steps.
Be sure that the chain is not too tight. A too tight chain may cause the operator to stall.
Turn power switch OFF and remove the control board.
Place a jumper wire from terminal 18 to terminal 17. CAUTION – HIGH VOLTAGE. Turn the power
switch on. The motor should run. Turn the power switch off and remove the jumper.
Place a jumper wire from terminal 18 to terminal 16. CAUTION – HIGH VOLTAGE. Turn the power
switch on. The motor should run in the opposite direction. Turn the power switch off and remove the jumper.
If the motor runs in both steps above, replace the control board. If the motor does not run, or runs
in only one direction, problem can be a bad motor, motor capacitor, wire connections from the control board to the motor or a bad control board.
Disconnect the gate from the gate operator and check that the gate moves freely without any
binding.
Re-adjust the open reverse sensitivity.
Replace the circuit board.
Gate opens but will not close.
1150-065-F-1-11
Check the input LEDs. Any ON will hold the gate open and indicates a problem with a external keying
device.
Check the secondary safety devices. Any that are activated will hold the gate open and indicates a
problem with the safety device.
Check the loop detectors. Any that are activated can hold the gate open and indicates a problem
with the loop detector or in-ground loop.
SW-2, switch 3 may be set incorrectly. Be sure that this switch is in the ON position for overhead
gate operation. Activate any external keying device to determine if operator returns to normal operation.
If automatic close timer is desired, be sure SW-1, switch 2 is ON.
Check motor:
Place a jumper wire from terminal 18 to terminal 17. CAUTION – HIGH VOLTAGE. Turn the power switch on. The motor should run. Turn the power switch off and remove the jumper.
Place a jumper wire from terminal 18 to terminal 16. CAUTION – HIGH VOLTAGE. Turn the power
switch on. The motor should run in the opposite direction. Turn the power switch off and remove the jumper. Continued on next page.
23
Symptom Possible Solution(s)
Continued from previous page.
Gate opens but will not close.
Gate closes but will not open.
If the motor runs in both steps from previous page, replace the control board. If the motor does not
run, or runs in only one direction, problem can be a bad motor, motor capacitor, wire connections from the control board to the motor or a bad control board.
SW-2, switch 3 may be set incorrectly. Be sure that this switch is in the ON position for overhead
gate operation. Activate any keying device to determine if operator returns to normal operation.
Check to be sure that the operator is running in the proper direction. Turn power OFF, and then back
ON. Activate an external keying device. Operator should run in the open direction. If operator runs in the close direction, turn power OFF and change direction switch SW-1, switch 1. Go to the previous symptom if operator now opens but will not close.
Be sure that the respective LED on the control board lights when the external keying device
connected to the respective terminal is activated. If LED does not light, momentarily place a jumper wire from terminal 1 to the input terminal being checked. If LED lights and gate opens, problem is with the external keying device. If LED does not light, replace control board.
Check motor:
Place a jumper wire from terminal 18 to terminal 17. CAUTION – HIGH VOLTAGE. Turn the power switch on. The motor should run. Turn the power switch off and remove the jumper.
Place a jumper wire from terminal 18 to terminal 16. CAUTION – HIGH VOLTAGE. Turn the power switch on. The motor should run in the opposite direction. Turn the power switch off and remove the jumper.
If the motor runs in both steps above, replace the control board. If the motor does not run, or runs
in only one direction, problem can be a bad motor, motor capacitor, wire connections from the control board to the motor or a bad control board.
Gate starts to close, then reverses to open.
Gate closes and then re-opens.
Loop detector LED is ON continuously.
Loop detector LED never activates.
Loop detectors do not open or reverse gate.
Re-adjust the close reverse sensitivity.
Disconnect the gate from the operator and check that the gate operates freely without any binding.
Check the loop detector LEDs and input LEDs. Any that flash ON will cause the gate to reverse.
Replace the circuit board.
Check for any input or loop detector LEDs that are ON.
Check that the operator is running in the proper direction, switch SW-1, switch 1 should be ON.
Activate the RESET switch on the loop detector.
Decrease loop detector sensitivity.
Check loop wire for resistance to ground with a meg-ohm meter. Should be 100 megohms or higher.
If less, problem may be with loop wire.
Be sure that lead-in wire from loop is twisted.
Be sure that all loop connections are soldered.
Replace loop detector.
Increase loop detector sensitivity.
Check continuity of loop wire. Should be 0 ohms. If continuity check indicates greater than 0 ohms,
check all connections or replace loop wire.
Move loop detector board to the other loop detector port on the control board, then check loop
operation. If loop detector still fails, replace loop board with a known good one. If problem continues, ground loop may be too small to detect vehicles – replace ground loop.
If loop detector LED illuminates when vehicle crosses over, problem may be in loop detector board.
Replace with a known good detector and re-check. If problem continues, control board may be bad.
If loop detector LED does not illuminate, see above symptom.
24
1150-065-F-1-11
4.4 Accessories
The following accessory items are available for the model 1150 overhead gate operator.
Contact Sensors - For use as a secondary entrapment protection device.
Miller Edge, Inc., ME120, ME123, MGO20, MGR20, MGS20.
Photo Cell - Non-contact (photo-cells) sensors for use as a secondary entrapment protection device.
P/N 8080-010 – Infrared thru-beam, 165 foot sensing distance. P/N 8080-011 – Photo-reflective beam, 30 foot sensing distance. P/N 8080-031 – Infrared thru-beam, 65 foot sensing distance. P/N 8080-031 – Polarized photo-reflective, 35 foot sensing distance.
Loop Detector - Detectors plug directly into ports on circuit board simplifying wiring.
P/N 9410-010 - Single channel detector P/N 9409-010 - Dual channel detector
Loop Wire - 18 AWG loop wire with XLPE insulation is ideal for ground loops. Available in 500 and 1000 foot rolls with red, blue
or black insulation.
Pre-Fab Loops - Prefabricated ground loops. 24-foot circumference with 50-foot lead-in. Available in yellow, red or blue jackets.
Not for use in asphalt roadways.
Control Station - Three button interior and exterior control stations provide manual open-close-stop gate operation.
P/N 1200-006 – Exterior / Interior P/N 1200-007 - Interior
Time Clock - 7 day and 365 day time clocks can be used to automatically open gate at pre-set time and days. Compact clock fits
inside the operator. P/N 2600-791 - 7 day clock P/N 2600-795 - 365 day clock
Surge Devices - High and low voltage surge suppressors help prevent circuit board failure caused by lightning strikes and
power surges. P/N 1876-010 - High Voltage P/N 1878-010 - Low Voltage
Gate Scale - Use to test torque required to move gate. P/N 2600-225
Speed Bumps - Prefabricated six-foot speed bump reduces traffic speed through gate system. P/N 1610-150
1150-065-F-1-11
25
1150 Wiring Schematic
Com
NONO
CLOSE
1
2
3
4
5
EXIT LOOP
Blue
12345
LIMIT LIMIT PART
Yellow
PUSH TO OPERATE
technician use only
Brown
Com
OPEN
ON
2 3 4 5 6 7 8
ON
1 2 3 41
6
TIME DELAY
7
8
9
REV SENSE
OPEN
REV SENSE CLOSE
10
11
12
13
NO NC
REVERSE LOOP
GATE FORCED
14
15
16
17
Red
Blue
1/2 HP
Single Phase
18
19
20
115 VAC
NEU HOT
Ground
Neutral
Hot
Chassis Ground
AC ON/OFF Power
26
1150-065-F-1-11
Owner’s Manual
1150
1150
Overhead Gate Operator
1150-065-F-1-11
DoorKing, Inc.
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Phone: 310-645-0023
Fax: 310-641-1586
www.doorking.com